Multicentre validation of IMRT pre-treatment verification: Comparison of in-house and external audit

被引:27
|
作者
Jornet, Nuria [1 ]
Carrasco, Pablo [1 ]
Beltran, Merce [2 ]
Francisco Calvo, Juan [3 ]
Escude, Lluis [4 ]
Hernandez, Victor [5 ]
Quera, Jaume [6 ]
Saez, Jordi [2 ]
机构
[1] Hosp Santa Creu & Sant Pau, Serv Radiofis & Radioproteccio, Barcelona, Spain
[2] Hosp Vall dHebro, Serv Fis, Barcelona, Spain
[3] Hosp Quiron, Serv Oncol Radioterap, Barcelona, Spain
[4] Clin Teknon, Serv Oncol Radioterap, Barcelona, Spain
[5] Hosp St Joan, Serv Fis, Reus, Spain
[6] Hosp Esperanza, Serv Oncol Radioterap, Barcelona, Spain
关键词
IMRT; Audit; Quality assurance; MODULATED RADIATION-THERAPY; RADIOCHROMIC FILM DOSIMETRY; QUALITY-ASSURANCE; EBT2; FILM; RADIOTHERAPY; COMPLEXITY; INDEX; QA;
D O I
10.1016/j.radonc.2014.06.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Materials and methods: Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. Results: While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Conclusions: Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [21] IMRT Pre-Treatment Verification in the Build-Up Region: Comparison of I' matriXX and EDR-2 Film
    Sharma, S.
    Manigandan, D.
    Subramani, V.
    Julka, P.
    Rath, G.
    MEDICAL PHYSICS, 2011, 38 (06) : 3524 - U133
  • [22] In-vivo and pre-treatment quality assurance software validation and verification
    Vanzi, E.
    Reversi, L.
    Giani, G.
    Arilli, C.
    Bonomo, P.
    Casati, M.
    Compagnucci, A.
    Greto, D.
    Marrazzo, L.
    Scoccianti, S.
    Pallotta, S.
    Bucciolini, M.
    Talamonti, C.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 671 - 673
  • [23] Preliminary Experience of Kuwait Cancer Control Center (KCCC) On IMRT Treatment Planning and Pre-Treatment Verification
    Sethuraman, T. K. R.
    Sherif, M.
    Subramanian, N.
    Zoueil, O.
    Mirza, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3524 - 3524
  • [24] A clinical approach to IMRT pre-treatment verfication
    Dvorak, P.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S203 - S203
  • [25] IMRT DOSIMETRY: DIRECT DOSE TO WATER DOSIMETRY FOR PRE-TREATMENT VERIFICATION USING A MODIFIED EPID
    Gustavsson, H.
    Vial, P.
    Kuncic, Z.
    Baldock, C.
    Greer, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S213 - S213
  • [26] Amorphous silicon flat panel imaging devices for pre-treatment verification and in vivo dosimetry of IMRT
    Wendling, M
    McDermott, LN
    van Asselen, B
    Sonke, JJ
    Stroom, J
    van Herk, M
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S15 - S15
  • [27] Dosimetric Verification of Gated IMRT Utilizing An In-House Developed Dynamic QA Device
    Liu, C.
    Xie, K.
    Pearson, D.
    Sperling, N.
    Parsai, E.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [28] The implementation in-house dose verification for IMRT and VMAT on breast cancer and NPC cases
    Azzi, A.
    Dimitri, F. Y.
    Pawiro, S. A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [29] Performance of An In-House Laser CT Scanner and Dose Verification for IMRT Using Gel
    Ravindran, P.
    Subramanian, B.
    Babu, E. Suman
    MEDICAL PHYSICS, 2008, 35 (06)
  • [30] Validation of local tolerances for Halcyon pre-treatment plan verification using PerFRACTION
    Ganesan, V.
    Ifthaker, A.
    Kidane, G.
    Withers, D.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1469 - S1469