Development of Electron Paramagnetic Resonance Magnet System for In Vivo Tooth Dosimetry

被引:4
|
作者
Choi, Kwon [1 ]
Koo, ChangUk [1 ]
Oh, JeongHun [1 ]
Park, Jong In [2 ]
Hirata, Hiroshi [3 ]
Ye, Sung-Joon [4 ,5 ,6 ,7 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Program Biomed Radiat Sci, Seoul 08826, South Korea
[2] Korea Res Inst Stand & Sci, Daejeon 34113, South Korea
[3] Hokkaido Univ, Fac Informat Sci & Technol, Div Bioengn & Bioinformat, Kita Ku, North 14,West 9, Sapporo, Hokkaido 0600814, Japan
[4] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Appl Bioengn, Seoul 08826, South Korea
[5] Seoul Natl Univ, Res Inst Convergence Sci, Seoul 08826, South Korea
[6] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon 16229, South Korea
[7] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
关键词
EPR DOSIMETRY; ENAMEL; DESIGN; SPECTROMETER; GEOMETRY; TRIAGE;
D O I
10.1155/2022/7332324
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
As part of a homebuilt continuous wave electron paramagnetic resonance (EPR) spectrometer operating at 1.2 GHz, a magnet system for in vivo tooth dosimetry was developed. The magnet was designed by adopting NdFeB permanent magnet (PM) for the main magnetic field generation. For each pole of the magnet, 32 cylindrical PMs were arranged in 2 axially aligned ring arrays. The pole gap was 18 cm, which was wide enough for a human head breadth. The measured magnetic field was compared with the magnetic field distribution calculated in a finite element method (FEM) simulation. EPR spectra of intact human teeth irradiated 5 and 30 Gy were measured for the performance test with the developed magnet system and spectrometer. The measured mean magnetic flux density was estimated to be 44.45 mT with homogeneity of 1,600 ppm in a 2 cm diameter of the spherical volume of the XY plane, which was comparable to the FEM simulation results. The sweep coefficient of the magnetic field sweep coil was 0.35 mT per Ampere in both the measurement and FEM simulation. With +/- 9 A current, the sweep range was 5.7 mT, which was sufficiently wide to measure the tooth radiation-induced signal (RIS) and reference material. The peak-to-peak amplitude of the measured modulation field was 0.38 mT at the center of the magnet. With the developed magnet fully integrated into an EPR system, the EPR spectra of 5 and 30 Gy irradiated teeth were successfully acquired. The developed magnet system showed sufficiently acceptable performance in terms of magnetic flux density and homogeneity. The EPR spectrum of tooth RIS could be measured ex vivo. The RIS of 5 and 30 Gy irradiated teeth was clearly distinguishable from intact human teeth.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Development and validation of an ex vivo electron paramagnetic resonance fingernail biodosimetric method
    He, Xiaoming
    Swarts, Steven G.
    Demidenko, Eugene
    Flood, Ann B.
    Grinberg, Oleg
    Gui, Jiang
    Mariani, Michael
    Marsh, Stephen D.
    Ruuge, Andres E.
    Sidabras, Jason W.
    Tipikin, Dmitry
    Wilcox, Dean E.
    Swartz, Harold M.
    RADIATION PROTECTION DOSIMETRY, 2014, 159 (1-4) : 172 - 181
  • [32] Q-band electron paramagnetic resonance dosimetry in tooth enamel: biopsy procedure and determination of dose detection limit
    Romanyukha, Alex
    Trompier, Francois
    Reyes, Ricardo A.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2014, 53 (02) : 305 - 310
  • [33] Design and Evaluation of a 1.1-GHz Surface Coil Resonator for Electron Paramagnetic Resonance-Based Tooth Dosimetry
    Sugawara, Hirotaka
    Hirata, Hiroshi
    Petryakov, Sergey
    Lesniewski, Piotr
    Williams, Benjamin B.
    Flood, Ann Barry
    Swartz, Harold M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (06) : 1894 - 1901
  • [34] Q-band electron paramagnetic resonance dosimetry in tooth enamel: biopsy procedure and determination of dose detection limit
    Alex Romanyukha
    François Trompier
    Ricardo A. Reyes
    Radiation and Environmental Biophysics, 2014, 53 : 305 - 310
  • [35] ELECTRON-PARAMAGNETIC RESONANCE STUDY OF IRRADIATED TOOTH ENAMEL
    CEVC, P
    SCHARA, M
    RAVNIK, C
    RADIATION RESEARCH, 1972, 51 (03) : 581 - &
  • [36] Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry
    Swarts, Steven G.
    Sidabras, Jason W.
    Grinberg, Oleg
    Tipikin, Dmitriy S.
    Kmiec, Maciej M.
    Petryakov, Sergey V.
    Schreiber, Wilson
    Wood, Victoria A.
    Williams, Benjamin B.
    Flood, Ann Barry
    Swartz, Harold M.
    HEALTH PHYSICS, 2018, 115 (01): : 140 - 150
  • [37] IN-VIVO DOSIMETRY BY ELECTRON SPIN RESONANCE SPECTROSCOPY
    SWARTZ, HM
    COPELAND, ES
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 137 - &
  • [38] ELECTRON PARAMAGNETIC RESONANCE DOSIMETRY FOR A LARGE-SCALE RADIATION INCIDENT
    Swartz, Harold M.
    Flood, Ann Barry
    Williams, Benjamin B.
    Dong, Ruhong
    Swarts, Steven G.
    He, Xiaoming
    Grinberg, Oleg
    Sidabras, Jason
    Demidenko, Eugene
    Gui, Jiang
    Gladstone, David J.
    Jarvis, Lesley A.
    Kmiec, Maciej M.
    Kobayashi, Kyo
    Lesniewski, Piotr N.
    Marsh, Stephen D. P.
    Matthews, Thomas P.
    Nicolalde, Roberto J.
    Pennington, Patrick M.
    Raynolds, Timothy
    Salikhov, Ildar
    Wilcox, Dean E.
    Zaki, Bassem I.
    HEALTH PHYSICS, 2012, 103 (03): : 255 - 267
  • [39] Dose Reconstruction Using Electron Paramagnetic Resonance Dosimetry on Tooth Enamel From Wild Boar Living in the Fukushima Exclusion Zone
    Harshman, Amber
    Johnson, Thomas
    HEALTH PHYSICS, 2019, 116 (06): : 799 - 806
  • [40] OPTIMIZATION OF ELECTRON-PARAMAGNETIC-RESONANCE DOSIMETRY FOR UNSEALED SOURCE RADIOTHERAPY
    BREEN, SL
    HOY, A
    BATTISTA, JJ
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P111 - P111