Development of Electron Paramagnetic Resonance Magnet System for In Vivo Tooth Dosimetry

被引:4
|
作者
Choi, Kwon [1 ]
Koo, ChangUk [1 ]
Oh, JeongHun [1 ]
Park, Jong In [2 ]
Hirata, Hiroshi [3 ]
Ye, Sung-Joon [4 ,5 ,6 ,7 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Program Biomed Radiat Sci, Seoul 08826, South Korea
[2] Korea Res Inst Stand & Sci, Daejeon 34113, South Korea
[3] Hokkaido Univ, Fac Informat Sci & Technol, Div Bioengn & Bioinformat, Kita Ku, North 14,West 9, Sapporo, Hokkaido 0600814, Japan
[4] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Appl Bioengn, Seoul 08826, South Korea
[5] Seoul Natl Univ, Res Inst Convergence Sci, Seoul 08826, South Korea
[6] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon 16229, South Korea
[7] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
关键词
EPR DOSIMETRY; ENAMEL; DESIGN; SPECTROMETER; GEOMETRY; TRIAGE;
D O I
10.1155/2022/7332324
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
As part of a homebuilt continuous wave electron paramagnetic resonance (EPR) spectrometer operating at 1.2 GHz, a magnet system for in vivo tooth dosimetry was developed. The magnet was designed by adopting NdFeB permanent magnet (PM) for the main magnetic field generation. For each pole of the magnet, 32 cylindrical PMs were arranged in 2 axially aligned ring arrays. The pole gap was 18 cm, which was wide enough for a human head breadth. The measured magnetic field was compared with the magnetic field distribution calculated in a finite element method (FEM) simulation. EPR spectra of intact human teeth irradiated 5 and 30 Gy were measured for the performance test with the developed magnet system and spectrometer. The measured mean magnetic flux density was estimated to be 44.45 mT with homogeneity of 1,600 ppm in a 2 cm diameter of the spherical volume of the XY plane, which was comparable to the FEM simulation results. The sweep coefficient of the magnetic field sweep coil was 0.35 mT per Ampere in both the measurement and FEM simulation. With +/- 9 A current, the sweep range was 5.7 mT, which was sufficiently wide to measure the tooth radiation-induced signal (RIS) and reference material. The peak-to-peak amplitude of the measured modulation field was 0.38 mT at the center of the magnet. With the developed magnet fully integrated into an EPR system, the EPR spectra of 5 and 30 Gy irradiated teeth were successfully acquired. The developed magnet system showed sufficiently acceptable performance in terms of magnetic flux density and homogeneity. The EPR spectrum of tooth RIS could be measured ex vivo. The RIS of 5 and 30 Gy irradiated teeth was clearly distinguishable from intact human teeth.