Effect of natural ventilation and manual airing on indoor air quality in naturally ventilated Italian classrooms

被引:91
|
作者
Stabile, Luca [1 ]
Dell'Isola, Marco [1 ]
Frattolillo, Andrea [2 ]
Massimo, Angelamaria [1 ]
Russi, Aldo [1 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Via Di Biasio 43, I-03043 Cassino, FR, Italy
[2] Univ Cagliari, Dept Civil & Environm Engn & Architecture, Cagliari, Italy
关键词
Schools; Exposure; Particles; Radon; Airing; Blower-door test; CO2; CARBON-DIOXIDE CONCENTRATION; PARTICLE CONCENTRATIONS; PARTICULATE MATTER; THERMAL CONDITIONS; SCHOOLS; HEALTH; SINGLE; INFILTRATION; PENETRATION; TIGHTNESS;
D O I
10.1016/j.buildenv.2016.01.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present work aimed to evaluate the effect of the ventilation on indoor air quality in Italian classrooms. To this end, schools located in the Central Italy were considered in the survey. The results of two experimental analyses are presented: a) data on classrooms' permeability and resultant air exchange rate, b) trends of indoor air quality parameters during heating and non-heating seasons to assess the possible effect of the manual airing technique. Pressurization tests were performed in 16 classrooms to evaluate their air infiltration due to envelope's leakages. The indoor air quality was investigated in 6 classrooms through CO2, particle number concentration and radon concentration measurements which were also related to the manual airing performed by window opening. Results of the pressurization tests revealed that, even in classrooms characterized by a poor maintenance state, the permeability of the envelopes was too low to guarantee acceptable air exchange rates. The analysis of the classrooms' air quality showed that during the fall and winter seasons the airing was ineffective, while it positively affected the indoor air quality during the spring season when strong reductions in CO2 and radon concentrations were recorded. The effect of the manual airing on the infiltration of outdoor generated pollutants was also assessed. As an example, a greater airing effect resulted in a higher penetration of sub-micrometric particles from outdoor: in fact, particle penetration factors of 0.83 and 1 were measured in fall/winter and spring seasons, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [31] The Impact of Traffic-Related Air Pollutants on the Indoor Air Quality of a Naturally Ventilated Building
    Tong, Zheming
    Chen, Yujiao
    Malkawi, Ali
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [32] THE POTENTIAL OF NATURAL VENTILATION IN SINGLE-SIDED VENTILATED APARTMENT TO IMPROVE INDOOR THERMAL COMFORT AND AIR QUALITY
    Mohamed, M. F.
    Behnia, M.
    King, S.
    Prasad, D.
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 71 - 78
  • [33] A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
    Jeannette TM Rosbach
    Machiel Vonk
    Frans Duijm
    Jan T van Ginkel
    Ulrike Gehring
    Bert Brunekreef
    Environmental Health, 12
  • [34] Prospects of Improving the Indoor Air Quality in Classrooms by Reactivating Historic Ventilation Stacks
    Hellwig, Runa T.
    Sedlmeier, Michael
    Tanzer, Christian
    INTERNATIONAL JOURNAL OF VENTILATION, 2015, 14 (02) : 141 - 152
  • [35] A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
    Rosbach, Jeannette T. M.
    Vonk, Machiel
    Duijm, Frans
    van Ginkel, Jan T.
    Gehring, Ulrike
    Brunekreef, Bert
    ENVIRONMENTAL HEALTH, 2013, 12
  • [36] Evaluation of Indoor Air Quality in Classrooms Equipped with Cross-Flow Ventilation
    Conceicao, Eusebio Z. E.
    Farinho, Joao P.
    Lucio, Ma Manuela J. R.
    INTERNATIONAL JOURNAL OF VENTILATION, 2012, 11 (01) : 53 - 67
  • [37] The Role of Portable Air Purifiers and Effective Ventilation in Improving Indoor Air Quality in University Classrooms
    Aldekheel, Mohammad
    Altuwayjiri, Abdulmalik
    Tohidi, Ramin
    Farahani, Vahid Jalali
    Sioutas, Constantinos
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (21)
  • [38] Indoor air quality and prevalence of asthma in office workers of a naturally ventilated antique building
    Rios, J.
    Boechat, J.
    Gottens, A.
    Ramos, C.
    Aquino, Neto F.
    Lapa e Silva, J.
    ALLERGY, 2008, 63 : 552 - 552
  • [39] FUZZY LOGIC CONTROLLER DEPLOYED FOR INDOOR AIR QUALITY CONTROL IN NATURALLY VENTILATED ENVIRONMENTS
    Jaradat, Mohammad Abdel Kareem
    Al-Nimr, Mohd A.
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (01): : 12 - 17
  • [40] Effect of natural ventilation on indoor air quality and thermal comfort in dormitory during winter
    Lei, Zhangping
    Liu, Chuanping
    Wang, Li
    Li, Na
    BUILDING AND ENVIRONMENT, 2017, 125 : 240 - 247