Effect of natural ventilation and manual airing on indoor air quality in naturally ventilated Italian classrooms

被引:91
|
作者
Stabile, Luca [1 ]
Dell'Isola, Marco [1 ]
Frattolillo, Andrea [2 ]
Massimo, Angelamaria [1 ]
Russi, Aldo [1 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Via Di Biasio 43, I-03043 Cassino, FR, Italy
[2] Univ Cagliari, Dept Civil & Environm Engn & Architecture, Cagliari, Italy
关键词
Schools; Exposure; Particles; Radon; Airing; Blower-door test; CO2; CARBON-DIOXIDE CONCENTRATION; PARTICLE CONCENTRATIONS; PARTICULATE MATTER; THERMAL CONDITIONS; SCHOOLS; HEALTH; SINGLE; INFILTRATION; PENETRATION; TIGHTNESS;
D O I
10.1016/j.buildenv.2016.01.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present work aimed to evaluate the effect of the ventilation on indoor air quality in Italian classrooms. To this end, schools located in the Central Italy were considered in the survey. The results of two experimental analyses are presented: a) data on classrooms' permeability and resultant air exchange rate, b) trends of indoor air quality parameters during heating and non-heating seasons to assess the possible effect of the manual airing technique. Pressurization tests were performed in 16 classrooms to evaluate their air infiltration due to envelope's leakages. The indoor air quality was investigated in 6 classrooms through CO2, particle number concentration and radon concentration measurements which were also related to the manual airing performed by window opening. Results of the pressurization tests revealed that, even in classrooms characterized by a poor maintenance state, the permeability of the envelopes was too low to guarantee acceptable air exchange rates. The analysis of the classrooms' air quality showed that during the fall and winter seasons the airing was ineffective, while it positively affected the indoor air quality during the spring season when strong reductions in CO2 and radon concentrations were recorded. The effect of the manual airing on the infiltration of outdoor generated pollutants was also assessed. As an example, a greater airing effect resulted in a higher penetration of sub-micrometric particles from outdoor: in fact, particle penetration factors of 0.83 and 1 were measured in fall/winter and spring seasons, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [21] Ventilation for Energy Efficiency and Improved Indoor Air Quality in University Classrooms
    Kumar, Sangeetha
    Nguyen, Annette
    Gayler, Kate
    Madigan, Grace
    Xing, Rachel
    Novoselac, Atila
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [22] Ventilation strategies and indoor air quality in Swedish primary school classrooms
    Cabovska, Blanka
    Beko, Gabriel
    Teli, Despoina
    Ekberg, Lars
    Dalenback, Jan-Olof
    Wargocki, Pawel
    Psomas, Theofanis
    Langer, Sarka
    BUILDING AND ENVIRONMENT, 2022, 226
  • [23] Indoor Air Quality in Naturally Ventilated Classrooms. Lessons Learned from a Case Study in a COVID-19 Scenario
    Meiss, Alberto
    Jimeno-Merino, Hector
    Poza-Casado, Irene
    Llorente-Alvarez, Alfredo
    Angel Padilla-Marcos, Miguel
    SUSTAINABILITY, 2021, 13 (15)
  • [24] Effect of ventilation strategy on indoor air relative humidity in naturally ventilated objects with various moisture buffer capacity
    Koronthalyova, O.
    RESEARCH ON BUILDING PHYSICS, 2010, : 499 - 503
  • [25] A comprehensive analysis of the intervention of a fresh air ventilation system on indoor air quality in classrooms
    Chen, Yu-Hao
    Tu, Yen-Pei
    Sung, Shih-Yi
    Weng, Wei-Cheng
    Huang, Hsiao-Lin
    Tsai, Ying, I
    ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (04)
  • [26] Inadequacy of air purifier for indoor air quality improvement in classrooms without external ventilation
    Choe, Youngtae
    Shin, Jun-shup
    Park, Jinhyeon
    Kim, Eunchae
    Oh, Narae
    Min, Kihong
    Kim, Dongjun
    Sung, Kyunghwa
    Cho, Mansu
    Yang, Wonho
    BUILDING AND ENVIRONMENT, 2022, 207
  • [27] Indoor and outdoor microbiological air quality in naturally and mechanically ventilated university libraries
    Hassan, Ahmad
    Zeeshan, Muhammad
    Bhatti, Muhammad Faraz
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (08)
  • [28] Effect of quality and maintenance of the ventilation to the indoor air quality
    Niskanen, J
    Valkeapää, A
    Anttonen, H
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 168 - 171
  • [29] Indoor environmental quality assessment in passively ventilated classrooms in Germany and estimation of ventilation energy losses
    Nehr, Sascha
    Baus, Lukas
    Cinar, Hasan
    Elsen, Ingo
    Frauenrath, Tobias
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [30] Developing a method to characterize indoor environmental parameters in naturally ventilated classrooms
    Mahyuddin, N.
    Awbi, H. B.
    PORTUGAL SB07 - SUSTAINABLE CONSTRUCTION, MATERIALS AND PRACTICES: CHALLENGE OF THE INDUSTRY FOR THE NEW MILLENNIUM, PTS 1 AND 2, 2007, : 411 - +