Portable FRET-Based Biosensor Device for On-Site Lead Detection

被引:17
|
作者
Lai, Wei-Qun [1 ,2 ]
Chang, Yu-Fen [3 ]
Chou, Fang-Ning [1 ]
Yang, De-Ming [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Med Res, Microscopy Serv Lab, Basic Res Div, Taipei 11217, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Inst Biophoton, Taipei 11221, Taiwan
[3] LumiSTAR Biotechnol Inc, Taipei 115, Taiwan
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 03期
关键词
lead biosensors; FRET; portable Pb sensor; smartphone-based device; Met-lead; tap water lead; groundwater lead; SIMULTANEOUS ELECTROCHEMICAL DETECTION; PB(II); OPTIMIZATION; PROTEIN; CD(II); WATER; IONS; TOOL;
D O I
10.3390/bios12030157
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Most methods for measuring environmental lead (Pb) content are time consuming, expensive, hazardous, and restricted to specific analytical systems. To provide a facile, safe tool to detect Pb, we created pMet-lead, a portable fluorescence resonance energy transfer (FRET)-based Pb-biosensor. The pMet-lead device comprises a 3D-printed frame housing a 405-nm laser diode-an excitation source for fluorescence emission images (YFP and CFP)-accompanied by optical filters, a customized sample holder with a Met-lead 1.44 M1 (the most recent version)-embedded biochip, and an optical lens aligned for smartphone compatibility. Measuring the emission ratios (Y/C) of the FRET components enabled Pb detection with a dynamic range of nearly 2 (1.96), a pMet-lead/Pb dissociation constant (K-d) 45.62 nM, and a limit of detection 24 nM (0.474 mu g/dL, 4.74 ppb). To mitigate earlier problems with a lack of selectivity for Pb vs. zinc, we preincubated samples with tricine, a low-affinity zinc chelator. We validated the pMet-lead measurements of the characterized laboratory samples and unknown samples from six regions in Taiwan by inductively coupled plasma mass spectrometry (ICP-MS). Notably, two unknown samples had Y/C ratios significantly higher than that of the control (3.48 +/- 0.08 and 3.74 +/- 0.12 vs. 2.79 +/- 0.02), along with Pb concentrations (10.6 ppb and 15.24 ppb) above the WHO-permitted level of 10 ppb in tap water, while the remaining four unknowns showed no detectable Pb upon ICP-MS. These results demonstrate that pMet-lead provides a rapid, sensitive means for on-site Pb detection in water from the environment and in living/drinking supply systems to prevent potential Pb poisoning.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] A FRET-based calcium biosensor with fast signal kinetics and high fluorescence change
    Mank, M
    Reiff, DF
    Heim, N
    Friedrich, MW
    Borst, A
    Griesbeck, O
    BIOPHYSICAL JOURNAL, 2006, 90 (05) : 1790 - 1796
  • [42] Critical Evaluation of FRET-Based Biosensor Performance: Implications for Measuring Ion Concentrations
    Palmer, Amy E.
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 340A - 340A
  • [43] Portable biosensor for on-site detection of kanamycin in water samples based on CRISPR-Cas12a and an off-the-shelf glucometer
    Chen, Junhua
    Shi, Gu
    Yan, Chong
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 872
  • [44] Genetically encoded FRET-based biosensor for imaging MMP-9 activity
    Stawarski, Michal
    Rutkowska-Wlodarczyk, Izabela
    Zeug, Andre
    Bijata, Monika
    Madej, Hubert
    Kaczmarek, Leszek
    Wlodarczyk, Jakub
    BIOMATERIALS, 2014, 35 (05) : 1402 - 1410
  • [45] Development of a Portable Intelligent Electric On-site Wrench Calibration Device
    Zhao, Yinming
    Xu, Jian
    Chai, Jixin
    Hao, Qun
    2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [46] Portable stir membrane device for on-site environmental sampling and extraction
    Antonio Casado-Carmona, Francisco
    del Carmen Alcudia-Leon, Maria
    Lucena, Rafael
    Cardenas, Soledad
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1606
  • [47] A portable paper-based testing device for fast and on-site determination of nitroxynil in food
    Xu, Zhongyong
    Song, Chao
    Chen, Zihao
    Zeng, Conghui
    Lv, Taoyuze
    Wang, Lei
    Liu, Bin
    ANALYTICA CHIMICA ACTA, 2023, 1260
  • [48] On-site discrimination of biothiols in biological fluids by a novel fluorescent probe and a portable fluorescence detection device
    Long, Lingliang
    Yuan, Fang
    Yang, Xinrong
    Ruan, Peng
    Chen, Xiaodong
    Li, Lulu
    He, Dan
    Yang, Sanxiu
    Yang, Yunfei
    Wang, Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [49] On-site discrimination of biothiols in biological fluids by a novel fluorescent probe and a portable fluorescence detection device
    Long, Lingliang
    Yuan, Fang
    Yang, Xinrong
    Ruan, Peng
    Chen, Xiaodong
    Li, Lulu
    He, Dan
    Yang, Sanxiu
    Yang, Yunfei
    Wang, Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [50] Portable device for detection of toxic chemicals using a yeast-based biosensor
    College of Engineering, Temple University
    不详
    不详
    Adv Microelectron, 2007, 1 (18-23):