Portable FRET-Based Biosensor Device for On-Site Lead Detection

被引:17
|
作者
Lai, Wei-Qun [1 ,2 ]
Chang, Yu-Fen [3 ]
Chou, Fang-Ning [1 ]
Yang, De-Ming [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Med Res, Microscopy Serv Lab, Basic Res Div, Taipei 11217, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Inst Biophoton, Taipei 11221, Taiwan
[3] LumiSTAR Biotechnol Inc, Taipei 115, Taiwan
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 03期
关键词
lead biosensors; FRET; portable Pb sensor; smartphone-based device; Met-lead; tap water lead; groundwater lead; SIMULTANEOUS ELECTROCHEMICAL DETECTION; PB(II); OPTIMIZATION; PROTEIN; CD(II); WATER; IONS; TOOL;
D O I
10.3390/bios12030157
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Most methods for measuring environmental lead (Pb) content are time consuming, expensive, hazardous, and restricted to specific analytical systems. To provide a facile, safe tool to detect Pb, we created pMet-lead, a portable fluorescence resonance energy transfer (FRET)-based Pb-biosensor. The pMet-lead device comprises a 3D-printed frame housing a 405-nm laser diode-an excitation source for fluorescence emission images (YFP and CFP)-accompanied by optical filters, a customized sample holder with a Met-lead 1.44 M1 (the most recent version)-embedded biochip, and an optical lens aligned for smartphone compatibility. Measuring the emission ratios (Y/C) of the FRET components enabled Pb detection with a dynamic range of nearly 2 (1.96), a pMet-lead/Pb dissociation constant (K-d) 45.62 nM, and a limit of detection 24 nM (0.474 mu g/dL, 4.74 ppb). To mitigate earlier problems with a lack of selectivity for Pb vs. zinc, we preincubated samples with tricine, a low-affinity zinc chelator. We validated the pMet-lead measurements of the characterized laboratory samples and unknown samples from six regions in Taiwan by inductively coupled plasma mass spectrometry (ICP-MS). Notably, two unknown samples had Y/C ratios significantly higher than that of the control (3.48 +/- 0.08 and 3.74 +/- 0.12 vs. 2.79 +/- 0.02), along with Pb concentrations (10.6 ppb and 15.24 ppb) above the WHO-permitted level of 10 ppb in tap water, while the remaining four unknowns showed no detectable Pb upon ICP-MS. These results demonstrate that pMet-lead provides a rapid, sensitive means for on-site Pb detection in water from the environment and in living/drinking supply systems to prevent potential Pb poisoning.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A FRET-based biosensor for measuring Gα13 activation in single cells
    Mastop, Marieke
    Reinhard, Nathalie R.
    Zuconelli, Cristiane R.
    Terwey, Fenna
    Gadella, Theodorus W. J., Jr.
    van Unen, Jakobus
    Adjobo-Hermans, Merel J. W.
    Goedhart, Joachim
    PLOS ONE, 2018, 13 (03):
  • [32] FRET-based aptamer biosensor for selective and sensitive detection of aflatoxin B1 in peanut and rice
    Sabet, Fereshte Sadat
    Hosseini, Morteza
    Khabbaz, Hossein
    Dadmehr, Mehdi
    Ganjali, Mohammad Reza
    FOOD CHEMISTRY, 2017, 220 : 527 - 532
  • [33] Validated portable device for the qualitative and quantitative electrochemical detection of MDMA ready for on-site use
    Van Echelpoel, Robin
    Parrilla, Marc
    Sleegers, Nick
    Shanmugam, Saranya Thiruvottriyur
    van Nuijs, Alexander L. N.
    Slosse, Amorn
    Van Durme, Filip
    De Wael, Karolien
    MICROCHEMICAL JOURNAL, 2023, 190
  • [34] FRET-Based Aptasensor for the Selective and Sensitive Detection of Lysozyme
    Sapkota, Kumar
    Dhakal, Soma
    SENSORS, 2020, 20 (03)
  • [35] A portable fluorescent sensor for on-site detection of microalgae
    Shin, Young-Ho
    Barnett, Jonathan Z.
    Song, Edward
    Gutierrez-Wing, M. Teresa
    Rusch, Kelly A.
    Choi, Jin-Woo
    MICROELECTRONIC ENGINEERING, 2015, 144 : 6 - 11
  • [36] FRET-based aptamer probe for rapid angiogenin detection
    Li, Wei
    Yang, Xiaohai
    Wang, Kemin
    Tan, Weihong
    Li, Huimin
    Ma, Changbei
    TALANTA, 2008, 75 (03) : 770 - 774
  • [37] FRET-based polymer materials for detection of cellular microenvironments
    Chuang Weng
    Nianqing Fan
    Taoran Xu
    Haodong Chen
    Zifen Li
    Yiwen Li
    Hong Tan
    Qiang Fu
    Mingming Ding
    ChineseChemicalLetters, 2020, 31 (06) : 1490 - 1498
  • [38] A spore-based portable kit for on-site detection of fluoride ions
    Qin, Yuqing
    Faheem, Aroosha
    Hu, Yonggang
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 419
  • [39] Optical design of portable Raman spectrometer based on-site rapid detection
    Luo, Weibo
    Yang, Jianfeng
    ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606
  • [40] FRET-based polymer materials for detection of cellular microenvironments
    Weng, Chuang
    Fan, Nianqing
    Xu, Taoran
    Chen, Haodong
    Li, Zifen
    Li, Yiwen
    Tan, Hong
    Fu, Qiang
    Ding, Mingming