Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis

被引:26
|
作者
Lindquist, Chris M. [1 ]
Karlicki, Fern [2 ]
Lawrence, Patrick [2 ]
Strzelczyk, Jacek [2 ]
Pawlyshyn, Neal [3 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] Univ Manitoba, Fac Med, Winnipeg, MB R3P 1X1, Canada
[2] St Boniface Gen Hosp, Dept Radiol, Winnipeg, MB R2H 2A6, Canada
[3] St Boniface Gen Hosp, Dept MRI, Winnipeg, MB R2H 2A6, Canada
关键词
balanced steady-state free precession; deep venous thrombosis; MR venography; trueFISP; ultrasound; ACUTE PULMONARY-EMBOLISM; VEIN-THROMBOSIS; ANGIOGRAPHY; TRUEFISP; SONOGRAPHY;
D O I
10.2214/AJR.09.3552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the sensitivity and specificity of balanced steady-state free precession MR venography in the diagnosis of lower extremity deep venous thrombosis. SUBJECTS AND METHODS. After undergoing lower extremity ultrasound because of suspicion of deep venous thrombosis, 64 patients were prospectively recruited to undergo balanced steady-state free precession MR venography with ultrasound as the reference standard. Ultrasound images were independently interpreted by two blinded ultrasound radiologists, and MR venograms were independently interpreted by two blinded MRI radiologists. The sensitivity, specificity, positive predictive value, and negative predictive value of MR venography were calculated for the diagnoses of all deep venous thrombosis, acute thrombi, and thrombosis of the popliteal, femoral, and common femoral veins individually. Proximal extent, thrombus age, ancillary findings, and interobserver agreement calculated with the Cohen kappa test were evaluated for ultrasound and MRI. The McNemar test was used to evaluate for statistical differences in diagnostic accuracy. RESULTS. MR venography had a sensitivity of 94.7%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 97.7% for the diagnosis of all thrombi. For acute thrombi, the MR venography and ultrasound results were completely concordant. MR venography depicted greater proximal extent in five of 18 cases in which thrombosis was found. The MR venographic findings agreed completely with the ultrasound findings in determination of thrombus age. For both ultrasound and MR venography, interobserver agreement was 100% on a per-patient basis. No statistical difference was identified in the diagnostic performance of the two techniques. CONCLUSION. Balanced steady-state free precession MR venography is highly accurate in the diagnosis of lower extremity deep venous thrombosis.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [41] Monitoring and Compensating Phase Imperfections in Cine Balanced Steady-State Free Precession
    Fischer, Rudolf Fritz
    Barmet, Christoph
    Rudin, Markus
    Boesiger, Peter
    Pruessmann, Klaas Paul
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1567 - 1579
  • [42] Spin-Locked Balanced Steady-State Free-Precession (slSSFP)
    Witschey, Walter R. T.
    Borthakur, Ari
    Elliott, Mark A.
    Magland, Jeremy
    McArdle, Erin L.
    Wheaton, Andrew
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 993 - 1001
  • [43] Magnetization evolution in balanced steady-state free precession with continuously moving table
    Stafford, Randall B.
    Sabati, Mohammad
    Mahallati, Houman
    Frayne, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : N173 - N184
  • [44] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335
  • [45] Abdominopelvic and Lower Extremity Deep Venous Thrombosis: Evaluation With Contrast-Enhanced MR Venography With a Blood-Pool Agent
    Huang, Steven Y.
    Kim, Charles Y.
    Miller, Michael J.
    Gupta, Rajan T.
    Lessne, Mark L.
    Horvath, Jeffrey J.
    Boll, Daniel T.
    Evans, Paul D.
    Befera, Nicholas T.
    Krishnan, Pranay
    Chan, Johanna L.
    Merkle, Elmar M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : 208 - 214
  • [46] Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs
    Imai, Fumito
    Kashiwagi, Ryosuke
    Imai, Hirohiko
    Iguchi, Satoshi
    Kimura, Atsuomi
    Fujiwara, Hideaki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (01) : 33 - 40
  • [47] Clinical Mimickers of Lower Extremity Deep Venous Thrombosis: Ultrasound Diagnosis
    Gunabushanam, G.
    Krishnamoorthy, S.
    Scoutt, L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [48] Duplex Ultrasound in the Diagnosis of Lower- Extremity Deep Venous Thrombosis
    Gornik, Heather L.
    Sharma, Aditya M.
    CIRCULATION, 2014, 129 (08) : 917 - 921
  • [49] Appearance of Normal Cranial Nerves on Steady-State Free Precession MR Images
    Sheth, Sujay
    Branstetter, Barton F.
    Escott, Edward J.
    RADIOGRAPHICS, 2009, 29 (04) : 1045 - 1056
  • [50] High sensitivity MR acoustic radiation force imaging using transition band balanced steady-state free precession
    Zheng, Yuan
    Marx, Michael
    Miller, G. Wilson
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1532 - 1537