Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis

被引:26
|
作者
Lindquist, Chris M. [1 ]
Karlicki, Fern [2 ]
Lawrence, Patrick [2 ]
Strzelczyk, Jacek [2 ]
Pawlyshyn, Neal [3 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] Univ Manitoba, Fac Med, Winnipeg, MB R3P 1X1, Canada
[2] St Boniface Gen Hosp, Dept Radiol, Winnipeg, MB R2H 2A6, Canada
[3] St Boniface Gen Hosp, Dept MRI, Winnipeg, MB R2H 2A6, Canada
关键词
balanced steady-state free precession; deep venous thrombosis; MR venography; trueFISP; ultrasound; ACUTE PULMONARY-EMBOLISM; VEIN-THROMBOSIS; ANGIOGRAPHY; TRUEFISP; SONOGRAPHY;
D O I
10.2214/AJR.09.3552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the sensitivity and specificity of balanced steady-state free precession MR venography in the diagnosis of lower extremity deep venous thrombosis. SUBJECTS AND METHODS. After undergoing lower extremity ultrasound because of suspicion of deep venous thrombosis, 64 patients were prospectively recruited to undergo balanced steady-state free precession MR venography with ultrasound as the reference standard. Ultrasound images were independently interpreted by two blinded ultrasound radiologists, and MR venograms were independently interpreted by two blinded MRI radiologists. The sensitivity, specificity, positive predictive value, and negative predictive value of MR venography were calculated for the diagnoses of all deep venous thrombosis, acute thrombi, and thrombosis of the popliteal, femoral, and common femoral veins individually. Proximal extent, thrombus age, ancillary findings, and interobserver agreement calculated with the Cohen kappa test were evaluated for ultrasound and MRI. The McNemar test was used to evaluate for statistical differences in diagnostic accuracy. RESULTS. MR venography had a sensitivity of 94.7%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 97.7% for the diagnosis of all thrombi. For acute thrombi, the MR venography and ultrasound results were completely concordant. MR venography depicted greater proximal extent in five of 18 cases in which thrombosis was found. The MR venographic findings agreed completely with the ultrasound findings in determination of thrombus age. For both ultrasound and MR venography, interobserver agreement was 100% on a per-patient basis. No statistical difference was identified in the diagnostic performance of the two techniques. CONCLUSION. Balanced steady-state free precession MR venography is highly accurate in the diagnosis of lower extremity deep venous thrombosis.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [21] Multidetector spiral CT venography in the diagnosis of upper extremity deep venous thrombosis
    Sabharwal, R.
    Boshell, D.
    Vladica, P.
    AUSTRALASIAN RADIOLOGY, 2007, 51 : B253 - B256
  • [22] Concomitant gradient field effects in balanced steady-state free precession
    Sica, Christopher T.
    Meyer, Craig H.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 721 - 730
  • [23] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [24] Motion resilience of the balanced steady-state free precession geometric solution
    Hoff, Michael N.
    Xiang, Qing-San
    Cross, Nathan M.
    Hippe, Daniel
    Andre, Jalal B.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 192 - 204
  • [25] Optimized balanced steady-state free precession magnetization transfer Imaging
    Bieri, O.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 511 - 518
  • [26] Multiple Repetition Time Balanced Steady-State Free Precession Imaging
    Cukur, Tolga
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 193 - 204
  • [27] Incremental lower extremity CT venography, a simplified approach for the diagnosis of deep venous thrombosis in patients with pulmonary embolism
    Nicolas, M
    Debelle, L
    Laurent, V
    Cannard, L
    Leclerc, JC
    Béot, S
    Régent, D
    JOURNAL DE RADIOLOGIE, 2001, 82 (03): : 251 - 256
  • [28] Assessment of deep venous thrombosis in the lower extremity in Behçet’s syndrome: MR venography versus Doppler ultrasonography
    Burcin Tutar
    Fatih Kantarci
    Osman Serdal Cakmak
    Hasan Yazici
    Emire Seyahi
    Internal and Emergency Medicine, 2019, 14 : 705 - 711
  • [29] Relaxometry and contrast-free cerebral microvascular quantification using balanced steady-state free precession MR fingerprinting
    Coudert, Thomas
    Delphin, Aurelien
    Barrier, Antoine
    Legris, Loic
    Warnking, Jan M.
    Lamalle, Laurent
    Doneva, Mariya
    Lemasson, Benjamin
    Barbier, Emmanuel L.
    Christen, Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [30] Depiction of lower limb venous anatomy in patients undergoing interventional deep venous reconstruction-the role of balanced steady state free precession MRI
    Helyar, Vincent G.
    Gupta, Yuri
    Blakeway, Lyndall
    Charles-Edwards, Geof
    Katsanos, Konstantinos
    Karunanithy, Narayan
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1082):