Improving Flow Measurement Accuracy Using a Portable Irrigation Turnout Calibration Unit

被引:0
|
作者
Styles, Stuart [1 ]
Feist, Kyle [1 ]
Burt, Charles [1 ]
机构
[1] Calif Polytech State Univ San Luis Obispo, Irrigat Training & Res Ctr, 1 Grand Ave, San Luis Obispo, CA 93407 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relatively accurate flow measurement at irrigation district water delivery points is an important component of volumetric billing and equitable service. In California, this has often occurred with conversions to pressurized irrigation systems which commonly include the installation of pipeline flow meters as part of the on-farm system. However, a large portion of irrigation turnouts in the western US continue to operate via gravity and fall into one of the following categories: (a) a metergate, or similar structure was installed without adherence to standard construction requirements, or (b) the structure was never intended for flow measurement. For these and other scenarios, there is a need to efficiently calibrate turnouts in the field. While some in-situ calibration methods exist for open channel turnouts, they are rarely applied in the field for a variety of practical reasons. After identifying this gap in field-practice, a special pump, or portable irrigation turnout calibration unit (calibration unit) was designed and constructed at the Cal Poly Irrigation Training and Research Center (ITRC). Within six weeks, thirty-two field turnout calibrations were performed using the Calibration Unit throughout seven California irrigation districts. Field testing protocol followed new guidelines developed by the USBR Mid Pacific Region and the California Department of Water Resources (DWR). The results and analyses of these calibrations are presented in this paper. Practical applications, such as compliance with California regulations developed out of The Water Conservation Act of 2009 (SB X7-7) and constraints of this new calibration method are also discussed.
引用
收藏
页码:424 / 438
页数:15
相关论文
共 50 条
  • [41] Improving interferometric radar measurement accuracy using local meteorological data
    Norland, Richard
    IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 4521 - 4524
  • [42] Improving Buildup Region Measurement Accuracy Using a Surface Location Method
    Ververs, J.
    McEwen, M.
    Siebers, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Shifted-phase calibration for improving the accuracy of orthogonal composite light 3-D measurement
    He, Yu-Hang
    Cao, Yi-Ping
    Zhai, Ai-Ping
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2011, 22 (03): : 404 - 408
  • [44] Assessment of ammonia sensors and photoacoustic measurement systems using a gas calibration unit
    von Jasmund, Naemi
    Schmithausen, Alexander J.
    Krommweh, Manuel S.
    Trimborn, Manfred
    Boeker, Peter
    Buescher, Wolfgang
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2022, 194
  • [45] Initial calibration of an inertial measurement unit using an optical position tracking system
    Kim, A
    Golnaraghi, MF
    PLANS 2004: POSITION LOCATION AND NAVIGATION SYMPOSIUM, 2004, : 96 - 101
  • [46] Improving the accuracy of MR flow quantification techniques using constrained optimization
    Nair, MS
    Duerk, JL
    Rittgers, SE
    RADIOLOGY, 1997, 205 : 888 - 888
  • [47] Development of the portable blood flow measurement system using laser speckle flowgraphy
    Shibata, Takumi
    Lee, Min-Chul
    Konishi, Naoki
    2013 INTERNATIONAL CONFERENCE ON ICT CONVERGENCE (ICTC 2013): FUTURE CREATIVE CONVERGENCE TECHNOLOGIES FOR NEW ICT ECOSYSTEMS, 2013, : 955 - 958
  • [48] High-precision Flow Measurement with Standard Flow Calibration Facilities - Methods and Validation Under Highest Accuracy Requirements
    Mathies, Nicolaus
    ATP EDITION, 2010, (7-8): : 42 - 49
  • [49] New aspects on improving the flow measurement with diaphragms, by using computers
    Cristea, M
    Agachi, S
    Imre, A
    REVISTA DE CHIMIE, 1998, 49 (01): : 50 - 55
  • [50] Precision and accuracy of stress measurement with a portable X-ray machine using an area detector
    Lee, Seung-Yub
    Ling, Jinjing
    Wang, Shenghe
    Ramirez-Rico, Joaquin
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2017, 50 : 131 - 144