Improving Flow Measurement Accuracy Using a Portable Irrigation Turnout Calibration Unit

被引:0
|
作者
Styles, Stuart [1 ]
Feist, Kyle [1 ]
Burt, Charles [1 ]
机构
[1] Calif Polytech State Univ San Luis Obispo, Irrigat Training & Res Ctr, 1 Grand Ave, San Luis Obispo, CA 93407 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relatively accurate flow measurement at irrigation district water delivery points is an important component of volumetric billing and equitable service. In California, this has often occurred with conversions to pressurized irrigation systems which commonly include the installation of pipeline flow meters as part of the on-farm system. However, a large portion of irrigation turnouts in the western US continue to operate via gravity and fall into one of the following categories: (a) a metergate, or similar structure was installed without adherence to standard construction requirements, or (b) the structure was never intended for flow measurement. For these and other scenarios, there is a need to efficiently calibrate turnouts in the field. While some in-situ calibration methods exist for open channel turnouts, they are rarely applied in the field for a variety of practical reasons. After identifying this gap in field-practice, a special pump, or portable irrigation turnout calibration unit (calibration unit) was designed and constructed at the Cal Poly Irrigation Training and Research Center (ITRC). Within six weeks, thirty-two field turnout calibrations were performed using the Calibration Unit throughout seven California irrigation districts. Field testing protocol followed new guidelines developed by the USBR Mid Pacific Region and the California Department of Water Resources (DWR). The results and analyses of these calibrations are presented in this paper. Practical applications, such as compliance with California regulations developed out of The Water Conservation Act of 2009 (SB X7-7) and constraints of this new calibration method are also discussed.
引用
收藏
页码:424 / 438
页数:15
相关论文
共 50 条
  • [31] Hybrid calibration method for improving 3D measurement accuracy of structured light systems
    Marrugo, Andres G.
    Vargas, Raul
    Zhang, Song
    Romero, Lenny A.
    INTERFEROMETRY XX, 2020, 11490
  • [32] Improving the Accuracy of COCOMO II Using Fuzzy Logic and Local Calibration Method
    Baiquni, Muhammad
    Sarno, Riyanarto
    Sarwosri
    Sholiq
    2017 3RD INTERNATIONAL CONFERENCE ON SCIENCE IN INFORMATION TECHNOLOGY (ICSITECH), 2017, : 284 - 289
  • [33] All-application-field Compensation Method for Improving Measurement Accuracy of Synchrophasor Measurement Unit for Distribution Network
    Wang Z.
    Shi B.
    Liu H.
    Xu Q.
    Xu S.
    Xiao Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (18): : 39 - 45
  • [34] A Transit Tilt and Offset Errors Calibration Method for Improving Laser Tracker Measurement Accuracy Based on the Telecentric Measurement System
    Wang, Shan
    Zhang, Zili
    Dong, Dengfeng
    Feng, Tianci
    Qiu, Qifan
    Meng, Fanchang
    Wang, Guoming
    Cui, Chengjun
    Ji, Rongyi
    Pan, Yingling
    Gong, Tao
    Zhou, Weihu
    APPLIED SCIENCES-BASEL, 2024, 14 (06):
  • [35] Improving calibration of groundwater flow models using headwater streamflow intermittence
    Abherve, Ronan
    Roques, Clement
    de Dreuzy, Jean-Raynald
    Datry, Thibault
    Brunner, Philip
    Longuevergne, Laurent
    Aquilina, Luc
    HYDROLOGICAL PROCESSES, 2024, 38 (06)
  • [36] Effective Measurement of the Wavelength Accuracy Calibration by Using Monte Carlo Uncertainty Calculation
    Kilin, M.
    Tutunculer, H.
    Meric, S.
    TURKISH PHYSICAL SOCIETY 35TH INTERNATIONAL PHYSICS CONGRESS (TPS35), 2019, 2178
  • [37] Consideration's for improving the accuracy of permittivity measurement using time domain reflectometry: Air-water calibration, effects of cable length
    Robinson, DA
    Schaap, M
    Jones, SB
    Friedman, SP
    Gardner, CMK
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2003, 67 (01) : 62 - 70
  • [38] Improving Positional Accuracy Using Relative Measurement between Android Smartphones
    Jang, Mingyun
    Kim, Dokyun
    Jung, Sejung
    Lee, Kirim
    Lee, Wonhee
    SENSORS AND MATERIALS, 2022, 34 (01) : 349 - 366
  • [39] Preliminary comparison of vibration measurement accuracy between a low cost, portable acceleration measurement unit and a gold-standard accelerometer system
    Pierson, Benjamin
    Faestel, Paul
    Spector, June T.
    Johnson, Peter
    APPLIED ERGONOMICS, 2021, 90
  • [40] Improving the measurement accuracy of hydrogen cyanide sensor by using DSP technique
    Ni, N.
    Chan, C. C.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2006, 8 (04): : 1613 - 1615