Improving Flow Measurement Accuracy Using a Portable Irrigation Turnout Calibration Unit

被引:0
|
作者
Styles, Stuart [1 ]
Feist, Kyle [1 ]
Burt, Charles [1 ]
机构
[1] Calif Polytech State Univ San Luis Obispo, Irrigat Training & Res Ctr, 1 Grand Ave, San Luis Obispo, CA 93407 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relatively accurate flow measurement at irrigation district water delivery points is an important component of volumetric billing and equitable service. In California, this has often occurred with conversions to pressurized irrigation systems which commonly include the installation of pipeline flow meters as part of the on-farm system. However, a large portion of irrigation turnouts in the western US continue to operate via gravity and fall into one of the following categories: (a) a metergate, or similar structure was installed without adherence to standard construction requirements, or (b) the structure was never intended for flow measurement. For these and other scenarios, there is a need to efficiently calibrate turnouts in the field. While some in-situ calibration methods exist for open channel turnouts, they are rarely applied in the field for a variety of practical reasons. After identifying this gap in field-practice, a special pump, or portable irrigation turnout calibration unit (calibration unit) was designed and constructed at the Cal Poly Irrigation Training and Research Center (ITRC). Within six weeks, thirty-two field turnout calibrations were performed using the Calibration Unit throughout seven California irrigation districts. Field testing protocol followed new guidelines developed by the USBR Mid Pacific Region and the California Department of Water Resources (DWR). The results and analyses of these calibrations are presented in this paper. Practical applications, such as compliance with California regulations developed out of The Water Conservation Act of 2009 (SB X7-7) and constraints of this new calibration method are also discussed.
引用
收藏
页码:424 / 438
页数:15
相关论文
共 50 条
  • [1] Portable sewage flow sensors - Their calibration and accuracy
    Watt, IA
    Jefferies, C
    WATER SCIENCE AND TECHNOLOGY, 1996, 33 (01) : 127 - 137
  • [2] Improving Accuracy of Inertial Measurement Unit using Discrete Wavelet Transform
    Jung, Jae-Hoon
    Lee, Dong-Hyuk
    Lee, Jang-Myung
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB2015), 2015, : 131 - 134
  • [3] Improving large angle flow measurement accuracy of five-hole probe using novel calibration coefficient and accuracy progressive neural network
    Zuo, Yueren
    Zhang, Haideng
    Wu, Yun
    FLOW MEASUREMENT AND INSTRUMENTATION, 2024, 99
  • [4] Improving the Accuracy of Continuous Blood Glucose Measurement Using Personalized Calibration and Machine Learning
    Kumari, Ranjita
    Anand, Pradeep Kumar
    Shin, Jitae
    DIAGNOSTICS, 2023, 13 (15)
  • [5] Improving the calibration process of inertial measurement unit for marine applications
    Rahimi, Hossein
    Nikkhah, Amir Ali
    NAVIGATION-JOURNAL OF THE INSTITUTE OF NAVIGATION, 2020, 67 (04): : 763 - 774
  • [6] Improving airflow measurement accuracy in VAV terminal units using flow conditioners
    Liu, Ran
    Wen, Jin
    Waring, Michael S.
    BUILDING AND ENVIRONMENT, 2014, 71 : 81 - 94
  • [7] Structured Methods for Improving Flow Measurement Accuracy in Pipelines
    G. N. Akhobadze
    Measurement Techniques, 2020, 63 : 361 - 367
  • [8] Structured Methods for Improving Flow Measurement Accuracy in Pipelines
    Akhobadze, G. N.
    MEASUREMENT TECHNIQUES, 2020, 63 (05) : 361 - 367
  • [9] Flow measurement using circular portable flume
    Kolavani, F. Lotfi
    Bijankhan, M.
    Di Stefano, C.
    Ferro, V
    Mazdeh, A. Mahdavi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 62 : 76 - 83
  • [10] Improving the Accuracy of Hydrodynamic Model Predictions Using Lagrangian Calibration
    Mardani, Neda
    Suara, Kabir
    Fairweather, Helen
    Brown, Richard
    McCallum, Adrian
    Sidle, Roy C.
    WATER, 2020, 12 (02)