Digital evaluation of the accuracy of impression techniques and materials in angulated implants

被引:42
|
作者
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
Ozcelik, Tuncer Burak [2 ]
Yagiz, Ayberk [3 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, TR-10 Mersin, Turkey
[2] Baskent Univ, Fac Dent, Dept Prosthodont, Adana, Turkey
[3] Ay Tasarim Ltd, Ankara, Turkey
关键词
Implant angulation; Splinted direct technique; Indirect technique; Vinyl polysiloxane; Polyether; Vinyl polyether silicone; IN-VITRO; SUPPORTED SUPERSTRUCTURES; 3-DIMENSIONAL ACCURACY; SURGICAL GUIDES; CONNECTION; PROSTHESES; SYSTEM; FIT; HYDROPHILICITY; SILICONE;
D O I
10.1016/j.jdent.2014.10.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants. Methods: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10 degrees or 20 degrees angulated) were fabricated. Two different impression techniques [ splinted direct (D), indirect (I)] and 3 different monophase impression materials [ polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n = 10). Master model and casts were scanned by a modified laser scanner and data were transferred to VRMesh software. Master model and duplicate cast scans were digitally aligned observing the superposition of anatomic markers. Angular and coronal deviations between master and duplicated copings were calculated and data were statistically analyzed. Results: Mean angular and coronal deviations were in a range of 0.205-0.359 degrees and 22.5633.33 mu m, respectively. Statistical analysis revealed that the angulation of implant affected both coronal and angular deviations of the impression copings (P < 0.05). According to statistical analyses, for parallel implants, the accuracy of impression materials and techniques were ranging as VPS-D = PE-D > VPS-I = PE-I > VPES-D > VPES-I from most accurate to the least. For 10 degrees and 20 degrees angulated implants the most accurate material and technique was VPS-D whereas the least accurate combination was VPES-I (P < 0.05). Conclusion: Angulation, impression technique and material were found to be effective on the accuracy of implant impressions. Clinical significance: Clinicians may prefer VPS impression material and splinted direct technique for impressions of both parallel and up to 20 degrees angulated implants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1551 / 1559
页数:9
相关论文
共 50 条
  • [21] Prosthetic transfer impression accuracy evaluation for osseointegrated implants
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Cardoso, Alessandra
    Rocha, Eduardo Passos
    Gomes, Erica Alves
    IMPLANT DENTISTRY, 2008, 17 (03) : 248 - 252
  • [22] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [23] The digital impression of implants
    Baresel, Ingo
    IMPLANTOLOGIE, 2023, 31 (01): : 37 - 46
  • [24] Effect of the Association Between the Tray and Impression Techniques on Angulated Implants Using the All-on-Four System
    de Avila, Erica Dorigatti
    Castanharo, Sabrina Maria
    Casalle, Nicole
    Vasconcelos, Juliano Alencar
    Mollo, Francisco de Assis, Jr.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 382 - 385
  • [25] EVALUATION OF 3 IMPRESSION TECHNIQUES FOR OSSEOINTEGRATED ORAL IMPLANTS
    INTURREGUI, JA
    AQUILINO, SA
    RYTHER, JS
    LUND, PS
    SOUTHARD, TE
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (05): : 503 - 509
  • [26] Evaluation of the Internal Accuracy of Molar Crowns Fabricated Using Digital and Conventional Impression Techniques
    Tartuk, Bulent Kadir
    Ayna, Emrah
    Basaran, Emine Goncu
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2018, 19 (03): : 240 - 246
  • [27] Evaluation of the accuracy of digital and conventional implant-level impression techniques for maxillofacial prosthesis
    Baghani, Mohammad Taghi
    Neshati, Ammar
    Sadafi, Mehdi
    Shidfar, Shireen
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2023, 12 (03) : 446 - 451
  • [28] IMPRESSION ACCURACY - A COMPARISON OF 3 TECHNIQUES AND 2 MATERIALS
    BURGESS, JO
    SMITH, JH
    KAISER, DA
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 304 - 304
  • [29] COMPARISON OF THE ACCURACY OF INTRAORAL SCANNING AND CONVENTIONAL IMPRESSION TECHNIQUES ON IMPLANTS: A REVIEW
    Arcuri, L.
    Lorenzi, C.
    Vanni, A.
    Bianchi, N.
    Dolci, A.
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 89 - 97
  • [30] Accuracy of Impression Techniques for Dental Implants Placed in Five Different Orientations
    Kim, Hyo-Seon
    Lee, Jae-Hyun
    Lee, Su Young