Synergetic effect of laser and micro-fabricated glow discharge plasma in a new ion source for ambient mass spectrometry

被引:1
|
作者
He, Feiyao [1 ]
Yin, Jinwei [1 ]
Wang, Tianzhi [1 ]
Pu, Juan [2 ]
Dai, Jianxiong [3 ]
Zhao, Zhongjun [4 ]
Duan, Yixiang [1 ]
机构
[1] Sichuan Univ, Coll Life Sci, Res Ctr Analyt Instrumentat, Key Lab Bioresource & Ecoenvironm,Minist Educ, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[3] Northwest Univ, Coll Chem & Mat Sci, Xian 710069, Peoples R China
[4] Sichuan Univ, Coll Chem Engn, Chengdu 610064, Peoples R China
关键词
Ambient ionization source; Laser ablation; Micro-fabricated glow discharge plasma; Synergetic effect; SONIC-SPRAY IONIZATION; ABLATION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE; DESORPTION-IONIZATION; IDENTIFICATION; EXPLORATION; METABOLITES; EXPLOSIVES; MFGDP; PROBE;
D O I
10.1016/j.talanta.2020.121847
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ambient ionization technique named laser ablation micro-fabricated glow discharge plasma (LA-MFGDP) was developed for mass spectrometry in this study. This technique used low energy laser for sample ablation and ionized sample aerosol with MFGDP in sequence. The combination of laser ablation and MFGDP exhibited a synergetic effect that significantly improved the performance of MFGDP. Experimental results showed that MFGDP dominated the ionization process while laser played the role of desorption in LA-MFGDP. [M+H](+) and M+ proved that proton transfer reactions and charge transfer reactions were involved in the ionization process, respectively, indicating that the ionization character was the same as MFGDP. LA-MFGDP could analyze less volatile samples that were unable to be detected by MFGDP because laser significantly improved the ionization capability of MFGDP. Strong ion signals were obtained by LA-MFGDP with low sample consumption. The limits of detection (LODs) of LA-MFGDP was as low as three orders of magnitude than that of MFGDP, which demonstrated that LA-MFGDP possessed an outstanding advantage in detecting trace substances. LA-MFGDP was successfully applied to detect pharmaceutical tablets without any pretreatment. Benefited from the excellent performance, LA-MFGDP offers great potential in broadening the application of ambient mass spectrometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Laser ablation inductively coupled plasma mass spectrometry - The role of the ion source for quantitative analysis
    Hattendorf, Bodo
    Wang, Zhongke
    Gunther, Detlef
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A385 - A385
  • [42] Surface analysis using a new plasma assisted desorption/ionisation source for mass spectrometry in ambient air
    Bowfield, A.
    Barrett, D. A.
    Alexander, M. R.
    Ortori, C. A.
    Rutten, F. M.
    Salter, T. L.
    Gilmore, I. S.
    Bradley, J. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (06):
  • [43] Method development for directly screening pesticide residues in foodstuffs using ambient microfabricated glow discharge plasma (MFGDP) desorption/ionization mass spectrometry
    Wang, Bo
    Ding, Xuelu
    Zhao, Zhongjun
    Duan, Yixiang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 507 - 514
  • [44] Development of soft ionization using direct current pulse glow discharge plasma source in mass spectrometry for volatile organic compounds analysis
    Nunome, Yoko
    Kodama, Kenji
    Ueki, Yasuaki
    Yoshiie, Ryo
    Naruse, Ichiro
    Wagatsuma, Kazuaki
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 139 : 44 - 49
  • [45] HIGH-MASS RESOLUTION GLOW-DISCHARGE MASS-SPECTROMETRY USING AN EXTERNAL ION-SOURCE FT-ICR MASS-SPECTROMETER
    WATSON, CH
    WRONKA, J
    LAUKIEN, FH
    BARSHICK, CM
    EYLER, JR
    ANALYTICAL CHEMISTRY, 1993, 65 (20) : 2801 - 2804
  • [46] A new ion source design for inductively coupled plasma mass spectrometry (ICP-MS)
    Scheffer, A
    Brandt, R
    Engelhard, C
    Evers, S
    Jakubowski, N
    Buscher, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (02) : 197 - 200
  • [47] Protein ion yield enhancement in matrix-assisted laser desorption/ionization mass spectrometry after sample and matrix low-pressure glow discharge plasma irradiation
    Hajiani, Shahedeh
    Ghassempour, Alireza
    Shokri, Babak
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (02)
  • [48] Effect of Ar/H2 and Kr/H2 mixtures as discharge gas on the ion intensity in dc glow discharge mass spectrometry
    Morimasa Saito
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 18 - 21
  • [49] Effect of Ar/H-2 and Kr/H-2 mixtures as discharge gas on the ion intensity in dc glow discharge mass spectrometry
    Saito, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01): : 18 - 21
  • [50] QUANTITATIVE ASSESSMENT OF A CORONA DISCHARGE ION-SOURCE IN ATMOSPHERIC-PRESSURE IONIZATION-MASS SPECTROMETRY FOR AMBIENT AIR MONITORING
    EICEMAN, GA
    KREMER, JH
    SNYDER, AP
    TOFFERI, JK
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1988, 33 (3-4) : 161 - 183