Synergetic effect of laser and micro-fabricated glow discharge plasma in a new ion source for ambient mass spectrometry

被引:1
|
作者
He, Feiyao [1 ]
Yin, Jinwei [1 ]
Wang, Tianzhi [1 ]
Pu, Juan [2 ]
Dai, Jianxiong [3 ]
Zhao, Zhongjun [4 ]
Duan, Yixiang [1 ]
机构
[1] Sichuan Univ, Coll Life Sci, Res Ctr Analyt Instrumentat, Key Lab Bioresource & Ecoenvironm,Minist Educ, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[3] Northwest Univ, Coll Chem & Mat Sci, Xian 710069, Peoples R China
[4] Sichuan Univ, Coll Chem Engn, Chengdu 610064, Peoples R China
关键词
Ambient ionization source; Laser ablation; Micro-fabricated glow discharge plasma; Synergetic effect; SONIC-SPRAY IONIZATION; ABLATION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE; DESORPTION-IONIZATION; IDENTIFICATION; EXPLORATION; METABOLITES; EXPLOSIVES; MFGDP; PROBE;
D O I
10.1016/j.talanta.2020.121847
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ambient ionization technique named laser ablation micro-fabricated glow discharge plasma (LA-MFGDP) was developed for mass spectrometry in this study. This technique used low energy laser for sample ablation and ionized sample aerosol with MFGDP in sequence. The combination of laser ablation and MFGDP exhibited a synergetic effect that significantly improved the performance of MFGDP. Experimental results showed that MFGDP dominated the ionization process while laser played the role of desorption in LA-MFGDP. [M+H](+) and M+ proved that proton transfer reactions and charge transfer reactions were involved in the ionization process, respectively, indicating that the ionization character was the same as MFGDP. LA-MFGDP could analyze less volatile samples that were unable to be detected by MFGDP because laser significantly improved the ionization capability of MFGDP. Strong ion signals were obtained by LA-MFGDP with low sample consumption. The limits of detection (LODs) of LA-MFGDP was as low as three orders of magnitude than that of MFGDP, which demonstrated that LA-MFGDP possessed an outstanding advantage in detecting trace substances. LA-MFGDP was successfully applied to detect pharmaceutical tablets without any pretreatment. Benefited from the excellent performance, LA-MFGDP offers great potential in broadening the application of ambient mass spectrometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Concomitant ion effects on isotope ratio measurements with liquid sampling - atmospheric pressure glow discharge ion source Orbitrap mass spectrometry
    Hoegg, Edward D.
    Marcus, R. Kenneth
    Hager, George J.
    Hart, Garret L.
    Koppenaal, David W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) : 251 - 259
  • [32] Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry
    Schwartz, Andrew J.
    Williams, Kelsey L.
    Hieftje, Gary M.
    Shelley, Jacob T.
    ANALYTICA CHIMICA ACTA, 2017, 950 : 119 - 128
  • [33] A simple glow discharge ion source for direct solid analysis by on-axis time-of-flight mass spectrometry
    Pisonero, J
    Costa, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) : 1253 - 1258
  • [34] Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge
    Na, Na
    Zhang, Chao
    Zhao, Mengxia
    Zhang, Sichun
    Yang, Chengdui
    Fang, Xiang
    Zhang, Xinrong
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (08): : 1079 - 1085
  • [35] Development and evaluation of a glow discharge microwave-induced-plasma tandem source for time-of-flight mass spectrometry
    Su, YX
    Duan, YX
    Jin, Z
    ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5600 - 5605
  • [36] Ambient desorption/ionization mass spectrometry using a liquid sampling-atmospheric glow discharge (LS-APGD) ionization source
    Marcus, R. Kenneth
    Burdette, Carolyn Q.
    Manard, Benjamin T.
    Zhang, Lynn X.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) : 8171 - 8184
  • [37] Can laser-ionisation time-of-flight mass spectrometry be a promising alternative to laser ablation/inductively-coupled plasma mass spectrometry and glow discharge mass spectrometry for the elemental analysis of solids?
    Sysoev, AA
    Sysoev, AA
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (03) : 213 - 232
  • [38] STUDY OF THE OPTIMIZATION AND THE DEPTH PROFILE USING A FLAT TYPE ION-SOURCE IN GLOW-DISCHARGE MASS-SPECTROMETRY
    WOO, JC
    KIM, HJ
    LIM, HB
    MOON, DW
    LEE, KW
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1992, 13 (06) : 620 - 624
  • [39] RF-pulsed glow discharge time-of-flight mass spectrometry for glass analysis: Investigation of the ion source design
    Bouza, Marcos
    Fernandez, Beatriz
    Gonzalez-Gago, Cristina
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2012, 756 : 30 - 36
  • [40] CHEMICAL IONIZATION MASS-SPECTROMETRY USING A GLOW-DISCHARGE ION-SOURCE COMBINED WITH A NEBULIZER SAMPLING SYSTEM
    MATSUMOTO, K
    KOJIMA, H
    YASUDA, K
    TSUGE, S
    ORGANIC MASS SPECTROMETRY, 1985, 20 (03): : 243 - 246