Synergetic effect of laser and micro-fabricated glow discharge plasma in a new ion source for ambient mass spectrometry

被引:1
|
作者
He, Feiyao [1 ]
Yin, Jinwei [1 ]
Wang, Tianzhi [1 ]
Pu, Juan [2 ]
Dai, Jianxiong [3 ]
Zhao, Zhongjun [4 ]
Duan, Yixiang [1 ]
机构
[1] Sichuan Univ, Coll Life Sci, Res Ctr Analyt Instrumentat, Key Lab Bioresource & Ecoenvironm,Minist Educ, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[3] Northwest Univ, Coll Chem & Mat Sci, Xian 710069, Peoples R China
[4] Sichuan Univ, Coll Chem Engn, Chengdu 610064, Peoples R China
关键词
Ambient ionization source; Laser ablation; Micro-fabricated glow discharge plasma; Synergetic effect; SONIC-SPRAY IONIZATION; ABLATION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE; DESORPTION-IONIZATION; IDENTIFICATION; EXPLORATION; METABOLITES; EXPLOSIVES; MFGDP; PROBE;
D O I
10.1016/j.talanta.2020.121847
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ambient ionization technique named laser ablation micro-fabricated glow discharge plasma (LA-MFGDP) was developed for mass spectrometry in this study. This technique used low energy laser for sample ablation and ionized sample aerosol with MFGDP in sequence. The combination of laser ablation and MFGDP exhibited a synergetic effect that significantly improved the performance of MFGDP. Experimental results showed that MFGDP dominated the ionization process while laser played the role of desorption in LA-MFGDP. [M+H](+) and M+ proved that proton transfer reactions and charge transfer reactions were involved in the ionization process, respectively, indicating that the ionization character was the same as MFGDP. LA-MFGDP could analyze less volatile samples that were unable to be detected by MFGDP because laser significantly improved the ionization capability of MFGDP. Strong ion signals were obtained by LA-MFGDP with low sample consumption. The limits of detection (LODs) of LA-MFGDP was as low as three orders of magnitude than that of MFGDP, which demonstrated that LA-MFGDP possessed an outstanding advantage in detecting trace substances. LA-MFGDP was successfully applied to detect pharmaceutical tablets without any pretreatment. Benefited from the excellent performance, LA-MFGDP offers great potential in broadening the application of ambient mass spectrometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Rapid identification and desorption mechanisms of nitrogen-based explosives by ambient micro-fabricated glow discharge plasma desorption/ionization (MFGDP) mass spectrometry
    Tian, CaiYan
    Yin, JinWei
    Zhao, ZhongJun
    Zhang, Yinchenxi
    Duan, YiXiang
    TALANTA, 2017, 167 : 75 - 85
  • [2] Trace detection of organophosphorus pesticides in vegetables via enrichment by magnetic zirconia and temperature-assisted ambient micro-fabricated glow discharge plasma desorption ionization mass spectrometry
    Yang, Yuhan
    Li, Yuting
    Huang, Zhijun
    Tian, Yonghui
    Qian, Cheng
    Duan, Yixiang
    ANALYST, 2021, 146 (22) : 6944 - 6954
  • [3] Modeling the effect of the cathode geometry in a DC glow discharge ion source for mass spectrometry
    Fiala, A
    Pitchford, LC
    Boeuf, JP
    Baude, S
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (04) : 531 - 536
  • [4] A Hollow-Cathode Ion Source in Glow Discharge Mass Spectrometry
    G. Fröhlich
    Journal of Analytical Chemistry, 2021, 76 : 112 - 128
  • [5] A Hollow-Cathode Ion Source in Glow Discharge Mass Spectrometry
    Froehlich , G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (01) : 112 - 128
  • [6] Microfabricated Glow Discharge Plasma (MFGDP) for Ambient Desorption/Ionization Mass Spectrometry
    Ding, Xuelu
    Zhan, Xuefang
    Yuan, Xin
    Zhao, Zhongjun
    Duan, Yixiang
    ANALYTICAL CHEMISTRY, 2013, 85 (19) : 9013 - 9020
  • [7] Development of a dielectric barrier discharge ion source for ambient mass spectrometry
    Na, Na
    Zhao, Mengxia
    Zhang, Sichun
    Yang, Chengdui
    Zhang, Xinrong
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) : 1859 - 1862
  • [8] STUDIES ON ION FORMATION IN A GLOW-DISCHARGE MASS-SPECTROMETRY ION-SOURCE
    VIETH, W
    HUNEKE, JC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (08) : 941 - 949
  • [9] Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
    Rejsek, Jan
    Vrkoslav, Vladimir
    Pokorny, Vit
    Pribyl, Vladimir
    Cvacka, Josef
    ANALYTICAL CHEMISTRY, 2017, 89 (21) : 11452 - 11459
  • [10] IMPROVEMENT OF ION-SOURCE PERFORMANCE IN GLOW-DISCHARGE MASS-SPECTROMETRY
    JAKUBOWSKI, N
    STUEWER, D
    TOELG, G
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 71 (02): : 183 - 197