A comparison of conventional tube test and gel technique in evaluation of direct antiglobulin test

被引:18
|
作者
Das, Sudipta S. [1 ]
Chaudhary, Rajendra [1 ]
Khetan, Dheeraj [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Transfus Med, Lucknow 226014, Uttar Pradesh, India
关键词
immunohematology; autoimmune hemolytic anemia; direct antiglobulin test; gel test; autoantibody;
D O I
10.1080/10245330601111862
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In vivo coating of red cells by antibody and/or complement is detected using various sensitive techniques, however most hospitals even today rely on the conventional tube technique (CTT). We compared the performance of the CTT and recently introduced gel test (GT) in the evaluation of direct antiglobulin test (DAT). The CTT and GT were first compared using in-house prepared control cells. The polyspecific DATs were performed simultaneously by CTT and GT on 170 consecutive blood samples. Positive samples were further tested for monospecific IgG and C3d by both techniques. GT demonstrated stronger agglutination scores (60 vs. 43) compared to CTT using control cells. The sensitivity and specificity of the GT was 98.4 and 95.2%, respectively as compared to CTT for polyspecific DAT. Discordance between the two test systems was seen in 6/170 patients. Of these, 5 were missed by CTT while GT failed to detect in vivo coating in only I case. The agreement between two methods of DAT was 96.4% (K = 0.926) using polyspecific AHG and 95.7% (K = 0.379) with monospecific anti-IgG. We conclude that GT is a better alternative to CTT for detecting red cell bound antibodies in various clinical conditions.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [1] A comparison of conventional tube technique and gel technique in evaluation of direct antiglobulin test
    Khetan, D.
    Chaudhary, R.
    Das, S.
    VOX SANGUINIS, 2006, 91 : 117 - 117
  • [2] Comparison of conventional tube test technique and gel microcolumn assay for direct antiglobulin test: A large study
    Novaretti, MCZ
    Jens, E
    Pagliarini, T
    Bonifacio, SL
    Dorlhiac-Llacer, PE
    Chamone, DAF
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2004, 18 (05) : 255 - 258
  • [3] Comparison between the conventional tube technique and the gel technique in direct antiglobulin tests
    Nathalang, O
    Chuansumrit, A
    Prayoonwiwat, W
    Siripoonya, P
    Sriphaisal, T
    VOX SANGUINIS, 1997, 72 (03) : 169 - 171
  • [4] Comparison of Conventional Tube Test and a Novel Gel Method to Detect C3d in the Direct Antiglobulin Test
    Vazquez-Gomez, G.
    Parsons, J.
    Peterson, T.
    Keller, M.
    Billingsley, K.
    Amniai, L.
    Roback, J.
    Chiu, J.
    TRANSFUSION, 2023, 63 : 178A - 179A
  • [5] The direct antiglobulin test: Still a place for the tube technique?
    Tissot, JD
    Kiener, C
    Burnand, B
    Schneider, P
    VOX SANGUINIS, 1999, 77 (04) : 223 - 226
  • [6] Positive direct antiglobulin test - A nuisance with gel technique.
    Pothiawala, M
    TRANSFUSION, 1996, 36 (09) : A20 - A20
  • [7] Performance of acid elution test by conventional tube test technique and gel test.
    Novaretti, MCZ
    Silveira, EJ
    Bonifacio, SL
    Dorlhiac-Llacer, PE
    Chamone, D
    TRANSFUSION, 2002, 42 (09) : 110S - 110S
  • [8] Comparison of gel and tube techniques for direct antiglobulin tests
    Sajur, J
    Fournier, Y
    Sheridan, B
    Heddle, NM
    TRANSFUSION, 1997, 37 (09) : S108 - S108
  • [9] The Direct Antiglobulin Test
    Parker, Victoria
    Tormey, Christopher A.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2017, 141 (02) : 305 - 310
  • [10] Is Direct Antiglobulin Test Crucial in the Evaluation of Neonatal Hyperbilirubinemia?
    Chen, Chung-Ming