In vivo coating of red cells by antibody and/or complement is detected using various sensitive techniques, however most hospitals even today rely on the conventional tube technique (CTT). We compared the performance of the CTT and recently introduced gel test (GT) in the evaluation of direct antiglobulin test (DAT). The CTT and GT were first compared using in-house prepared control cells. The polyspecific DATs were performed simultaneously by CTT and GT on 170 consecutive blood samples. Positive samples were further tested for monospecific IgG and C3d by both techniques. GT demonstrated stronger agglutination scores (60 vs. 43) compared to CTT using control cells. The sensitivity and specificity of the GT was 98.4 and 95.2%, respectively as compared to CTT for polyspecific DAT. Discordance between the two test systems was seen in 6/170 patients. Of these, 5 were missed by CTT while GT failed to detect in vivo coating in only I case. The agreement between two methods of DAT was 96.4% (K = 0.926) using polyspecific AHG and 95.7% (K = 0.379) with monospecific anti-IgG. We conclude that GT is a better alternative to CTT for detecting red cell bound antibodies in various clinical conditions.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [31] Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration
    Finck, Rachel
    Lui-Deguzman, Carrie
    Teng, Shih-Mao
    Davis, Rebecca
    Yuan, Shan
    TRANSFUSION, 2013, 53 (04) : 811 - 815
  • [32] Comparison of conventional tube test with diamed gel microcolumn assay for anti-D titration
    Novaretti, MCZ
    Jens, E
    Pagliarini, T
    Bonifácio, SL
    Dorlhiac-Llacer, PE
    Chamone, DAF
    CLINICAL AND LABORATORY HAEMATOLOGY, 2003, 25 (05): : 311 - 315
  • [33] Evaluation and implementation of the gel test for indirect antiglobulin testing in a community hospital laboratory
    Cate, JC
    Reilly, N
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1999, 123 (08) : 693 - 697
  • [34] Direct antiglobulin test positivity in Serbian blood donors in the era of gel card technology
    Grujic, Jasmina
    Bujandric, Nevenka
    Malenkovic, Goran
    Budakov Obradovic, Zorana
    VOX SANGUINIS, 2023, 118 (06) : 497 - 501
  • [35] A TIME STUDY COMPARISON OF THE GEL TEST AND STANDARD TEST-TUBE AGGLUTINATION
    SOSLER, SD
    SAPORITO, C
    DECHRISTOPHER, PJ
    TRANSFUSION, 1994, 34 (10) : S83 - S83
  • [36] Usefulness of direct antiglobulin test in neonatal screening
    Baptista-Gonzalez, Hector
    Alberto Hernandez-Martinez, Jose
    Galindo-Delgado, Patricia
    Santamaria-Hernandez, Carmen
    Rosenfeld-Mann, Fany
    BOLETIN MEDICO DEL HOSPITAL INFANTIL DE MEXICO, 2009, 66 (06): : 502 - 510
  • [37] How to use: the direct antiglobulin test in newborns
    Keir, Amy
    Agpalo, Minda
    Lieberman, Lani
    Callum, Jeannie
    ARCHIVES OF DISEASE IN CHILDHOOD-EDUCATION AND PRACTICE EDITION, 2015, 100 (04): : 198 - 203
  • [38] THE COOMBS DIRECT ANTIGLOBULIN-TEST IN KENYANS
    ABDALLA, SH
    KASILI, FG
    WEATHERALL, DJ
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1983, 77 (01) : 99 - 102
  • [39] DOT BLOT DIRECT ANTIGLOBULIN-TEST
    PLAPP, FV
    RACHEL, JM
    SINOR, LT
    TRANSFUSION, 1986, 26 (06) : 571 - 571
  • [40] The direct antiglobulin test in autoimmune lymphoproliferative syndrome
    Stroncek, DF
    Carter, LB
    Procter, JL
    TRANSFUSION, 1999, 39 (10) : 81S - 82S