Measurement of oxygen isotope ratios (18O/16O) of aqueous O2 in small samples by gas chromatography/isotope ratio mass spectrometry

被引:13
|
作者
Pati, Sarah G. [1 ,2 ]
Bolotin, Jakov [1 ]
Brennwald, Matthias S. [1 ]
Kohler, Hans-Peter E. [1 ,2 ]
Werner, Roland A. [3 ]
Hofstetter, Thomas B. [1 ,2 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] ETH, Inst Biogeochem & Pollutant Dynam IBP, CH-8092 Zurich, Switzerland
[3] ETH, Inst Agr Sci, CH-8092 Zurich, Switzerland
关键词
ATMOSPHERIC OXYGEN; DISSOLVED-OXYGEN; FRACTIONATION; ACTIVATION; O-18; CONSUMPTION; DELTA-O-18; PRECISION; ENZYMES; TRACER;
D O I
10.1002/rcm.7481
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleOxygen isotope fractionation of molecular O-2 is an important process for the study of aerobic metabolism, photosynthesis, and formation of reactive oxygen species. The latter is of particular interest for investigating the mechanism of enzyme-catalyzed reactions, such as the oxygenation of organic pollutants, which is an important detoxification mechanism. MethodsWe developed a simple method to measure the O-18 values of dissolved O-2 in small samples using automated split injection for gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS). After creating a N-2 headspace, the dissolved O-2 partitions from aqueous solution to the headspace, from which it can be injected into the gas chromatograph. ResultsIn aqueous samples of 10mL and in diluted air samples, we quantified the O-18 values at O-2 concentrations of 16M and 86M, respectively. The chromatographic separation of O-2 and N-2 with a molecular sieve column made it possible to use N-2 as the headspace gas for the extraction of dissolved O-2 from water. We were therefore able to apply a rigorous O-18 blank correction for the quantification of O-18/O-16 ratios in 20nmol of injected O-2. ConclusionsThe successful quantification of O-18-kinetic isotope effects associated with enzymatic and chemical reduction of dissolved O-2 illustrates how the proposed method can be applied for studying enzymatic O-2 activation mechanisms in a variety of (bio)chemical processes. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:684 / 690
页数:7
相关论文
共 50 条
  • [41] Isotopic analysis of ethanol:: study on 18O/16O measurement using a high-temperature pyrolysis system coupled to an isotope ratio mass spectrometer
    Calderone, G
    Reniero, F
    Guillou, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (05) : 937 - 940
  • [42] A novel methodological approach for δ18O analysis of sugars using gas chromatography-pyrolysis-isotope ratio mass spectrometry
    Zech, Michael
    Saurer, Matthias
    Tuthorn, Mario
    Rinne, Katja
    Werner, Roland A.
    Siegwolf, Rolf
    Glaser, Bruno
    Juchelka, Dieter
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2013, 49 (04) : 492 - 502
  • [43] Rapid and precise determination of the δ18O of dissolved and gaseous dioxygen via gas chromatography-isotope ratio mass spectrometry
    Roberts, BJ
    Russ, ME
    Ostrom, NE
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (11) : 2337 - 2341
  • [44] Fractionation of Oxygen Isotopes by Thermal Ionization Mass Spectrometry Inferred from Simultaneous Measurement of 17O/16O and 18O/16O Ratios and Implications for the 182Hf-182W Systematics
    Trinquier, Anne
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5600 - 5604
  • [45] High-precision measurements of 17O/16O and 18O/16O ratios in CO2
    Barkan, Eugeni
    Luz, Boaz
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2733 - 2738
  • [46] Automated analyses of 18O/16O ratios in dissolved oxygen from 12-mL water samples
    Barth, JAC
    Tait, A
    Bolshaw, M
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2004, 2 : 35 - 41
  • [47] Inaccuracies in selected ion monitoring determination of isotope ratios obviated by profile acquisition:: nucleotide 18O/16O measurements
    Cassano, Adam G.
    Wang, Benlian
    Anderson, David R.
    Previs, Stephen
    Harris, Michael E.
    Anderson, Vernon E.
    ANALYTICAL BIOCHEMISTRY, 2007, 367 (01) : 28 - 39
  • [48] Determination of the 2H/1H, 17O/16O, and 18O/16O isotope ratios in water by means of tunable diode laser spectroscopy at 1.39 μm
    Kerstel, ERT
    Gagliardi, G
    Gianfrani, L
    Meijer, HAJ
    van Trigt, R
    Ramaker, R
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) : 2389 - 2396
  • [49] Effects of temperature and carbon source on the isotopic fractionations associated with O2 respiration for 17O/16O and 18O/16O ratios in E. coli
    Stolper, Daniel A.
    Fischer, Woodward W.
    Bender, Michael L.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2018, 240 : 152 - 172
  • [50] Gas chromatography-mass spectrometry based 18O stable isotope labeling of Krebs cycle intermediates
    Eylem, Cemil Can
    Baysal, Ipek
    Erikci, Acelya
    Yabanoglu-Ciftci, Samiye
    Zhang, Song
    Kir, Sedef
    Terzic, Andre
    Dzeja, Petras
    Nemutlu, Emirhan
    ANALYTICA CHIMICA ACTA, 2021, 1154