Measurement of oxygen isotope ratios (18O/16O) of aqueous O2 in small samples by gas chromatography/isotope ratio mass spectrometry

被引:13
|
作者
Pati, Sarah G. [1 ,2 ]
Bolotin, Jakov [1 ]
Brennwald, Matthias S. [1 ]
Kohler, Hans-Peter E. [1 ,2 ]
Werner, Roland A. [3 ]
Hofstetter, Thomas B. [1 ,2 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] ETH, Inst Biogeochem & Pollutant Dynam IBP, CH-8092 Zurich, Switzerland
[3] ETH, Inst Agr Sci, CH-8092 Zurich, Switzerland
关键词
ATMOSPHERIC OXYGEN; DISSOLVED-OXYGEN; FRACTIONATION; ACTIVATION; O-18; CONSUMPTION; DELTA-O-18; PRECISION; ENZYMES; TRACER;
D O I
10.1002/rcm.7481
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleOxygen isotope fractionation of molecular O-2 is an important process for the study of aerobic metabolism, photosynthesis, and formation of reactive oxygen species. The latter is of particular interest for investigating the mechanism of enzyme-catalyzed reactions, such as the oxygenation of organic pollutants, which is an important detoxification mechanism. MethodsWe developed a simple method to measure the O-18 values of dissolved O-2 in small samples using automated split injection for gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS). After creating a N-2 headspace, the dissolved O-2 partitions from aqueous solution to the headspace, from which it can be injected into the gas chromatograph. ResultsIn aqueous samples of 10mL and in diluted air samples, we quantified the O-18 values at O-2 concentrations of 16M and 86M, respectively. The chromatographic separation of O-2 and N-2 with a molecular sieve column made it possible to use N-2 as the headspace gas for the extraction of dissolved O-2 from water. We were therefore able to apply a rigorous O-18 blank correction for the quantification of O-18/O-16 ratios in 20nmol of injected O-2. ConclusionsThe successful quantification of O-18-kinetic isotope effects associated with enzymatic and chemical reduction of dissolved O-2 illustrates how the proposed method can be applied for studying enzymatic O-2 activation mechanisms in a variety of (bio)chemical processes. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:684 / 690
页数:7
相关论文
共 50 条
  • [31] A technique for the determination of 18O/16O and 17O/16O isotopic ratios in water from small liquid and solid samples
    Baker, L
    Franchi, IA
    Maynard, J
    Wright, IP
    Pillinger, CT
    ANALYTICAL CHEMISTRY, 2002, 74 (07) : 1665 - 1673
  • [32] First measurement of the 18O/16O and 17O/16O ratios in stratospheric nitrous oxide:: A mass-independent anomaly
    Cliff, SS
    Brenninkmeijer, CAM
    Thiemens, MH
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1999, 104 (D13) : 16171 - 16175
  • [33] The effect of marine photosynthesis on 17O/16O and 18O/16O of atmospheric O2
    Barkan, E.
    Eisenstadt, D.
    Kaplan, A.
    Luz, B.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A88 - A88
  • [34] Improving the accuracy of δ18O and δ17O values of O2 measured by continuous-flow isotope-ratio mass spectrometry with a multipoint isotope-ratio calibration
    de Carvalho, Carolina F. M.
    Lehmann, Moritz F.
    Pati, Sarah G.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (01)
  • [35] 18O/16O ratio measurements of inorganic and organic materials by elemental analysis-pyrolysis-isotope ratio mass spectrometry continuous-flow techniques
    Fourel, Francois
    Martineau, Francois
    Lecuyer, Christophe
    Kupka, Hans-Joachim
    Lange, Lutz
    Ojeimi, Charles
    Seed, Mike
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (19) : 2691 - 2696
  • [36] Oxygen transport in electroceramics investigated by electrochemical 18O/16O isotope exchange and ToF-SIMS
    Langer-Hansel, K.
    Schintlmeister, A.
    Fleig, J.
    Hutter, H.
    SURFACE AND INTERFACE ANALYSIS, 2013, 45 (01) : 486 - 489
  • [37] Partial pressure dependency of 17O/16O and 18O/16O of molecular oxygen in the mass spectrometer
    Abe, O
    Yoshida, N
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (05) : 395 - 400
  • [38] Optimized Method for Computing 18O/16O Ratios of Differentially Stable-Isotope Labeled Peptides in the Context of Postdigestion 18O Exchange/Labeling
    Ye, Xiaoying
    Luke, Brian T.
    Johann, Donald J., Jr.
    Ono, Akira
    Prieto, DaRue A.
    Chan, King C.
    Issaq, Haleem J.
    Veenstra, Timothy D.
    Blonder, Josip
    ANALYTICAL CHEMISTRY, 2010, 82 (13) : 5878 - 5886
  • [39] High precision measurements of 17O/16O and 18O/16O ratios in H2O
    Barkan, E
    Luz, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (24) : 3737 - 3742
  • [40] Rapid 18O analysis of CO2 samples by continuous-flow isotope ratio mass spectrometry
    Schoeller, DA
    Luke, AH
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (12): : 1332 - 1336