Comparison of the marginal fit of Procera AllCeram crowns with two finish lines

被引:0
|
作者
Suárez, MJ [1 ]
de Villaumbrosia, PG
Pradíes, G
Lozano, JFL
机构
[1] Univ Complutense, Dept Buccofacial Prosthesis, Madrid 28040, Spain
[2] Univ Complutense, Fac Odontol, Madrid, Spain
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to determine the influence of two finish line configurations on the marginal accuracy of Procera AllCeram crowns. Materials and Methods: Twenty mechanized specimens of brass were fabricated for complete-coverage crowns. Two finish line designs were used: chamfer and rounded shoulder. AllCeram crowns were fabricated, and the fit of the crowns to the dies was recorded from the buccal and lingual margins. An image-analysis program was used to measure the gap. The results were subjected to statistical analysis using a Student's t test for separate samples and Student's paired t test. Results: No significant differences were observed between the buccal and lingual measurements. When the values of the buccal and lingual measurements were averaged, there were no significant differences in the marginal gap, horizontal discrepancy, or internal adaptation of the axial wall, but there were significant differences in the vertical discrepancy, absolute marginal discrepancy, and internal discrepancy between the two finish line designs. Conclusion: The marginal gap was within the range of clinical acceptability. Some of the variables were influenced by the two finish lines tested.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 50 条
  • [41] An In Vitro Comparison of Zirconia and Hybrid Ceramic Crowns With Heavy Chamfer and Shoulder Finish Lines
    Yadav, Priyanka
    Sharma, Vineet
    Paliwal, Jyoti
    Meena, Kamal K.
    Madaan, Rahul
    Gurjar, Balwant
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [42] Marginal fit of titanium metal-ceramic crowns
    Suárez, MJ
    Lozano, JFL
    Salido, MP
    Martínez, F
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2005, 18 (05) : 390 - 391
  • [43] Evaluation of the marginal fit of implant-supported crowns
    Akmal N.L.H.B.I.
    Duraisamy R.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (03): : 165 - 172
  • [44] Marginal fit and strength of porcelain crowns on Branemark implants
    Kersten, S
    Strub, JR
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 936 - 936
  • [45] Two years of clinical experience with Procera titanium crowns
    Milleding, P
    Haag, P
    Neroth, B
    Renz, I
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1998, 11 (03) : 224 - 232
  • [46] Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
    Son, Keunbada
    Son, Young-Tak
    Lee, Ji-Min
    Lee, Kyu-Bok
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
    Keunbada Son
    Young-Tak Son
    Ji-Min Lee
    Kyu-Bok Lee
    Scientific Reports, 11
  • [48] AN IN VIVO STUDY TO COMPARE THE MARGINAL FIT ACCURACY OF CROWNS PREPARED USING TWO DIFFERENT MATERIALS
    Roy, Malvika Suresh
    Tewary, Shivsagar
    Sanyal, Pronob
    Kamnoor, Shubha
    Vande, Aaditee
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (24): : 1930 - 1934
  • [49] Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations
    Faruqi, Saif
    Ganji, Kiran Kumar
    Bandela, Vinod
    Nagarajappa, Anil Kumar
    Mohamed, Roshan Noor
    Al Ahmed, Muhannad
    Farhan, Mohammed
    Alwakid, Waleed Naif
    Al-Hammad, Kholood A. S.
    Alam, Mohammad Khursheed
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 789 - 795
  • [50] Correlation between polymerization shrinkage and marginal fit of temporary crowns
    Balkenhol, Markus
    Knapp, Michael
    Ferger, Paul
    Heun, Ulrich
    Woestmann, Bernd
    DENTAL MATERIALS, 2008, 24 (11) : 1575 - 1584