Purpose: The purpose of this study was to determine the influence of two finish line configurations on the marginal accuracy of Procera AllCeram crowns. Materials and Methods: Twenty mechanized specimens of brass were fabricated for complete-coverage crowns. Two finish line designs were used: chamfer and rounded shoulder. AllCeram crowns were fabricated, and the fit of the crowns to the dies was recorded from the buccal and lingual margins. An image-analysis program was used to measure the gap. The results were subjected to statistical analysis using a Student's t test for separate samples and Student's paired t test. Results: No significant differences were observed between the buccal and lingual measurements. When the values of the buccal and lingual measurements were averaged, there were no significant differences in the marginal gap, horizontal discrepancy, or internal adaptation of the axial wall, but there were significant differences in the vertical discrepancy, absolute marginal discrepancy, and internal discrepancy between the two finish line designs. Conclusion: The marginal gap was within the range of clinical acceptability. Some of the variables were influenced by the two finish lines tested.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 50 条
  • [21] Clinical evaluation of Procera AllCeram crowns in Japanese patients: results after 5 years
    Kokubo, Y.
    Sakurai, S.
    Tsumita, M.
    Ogawa, T.
    Fukushima, S.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (11) : 786 - 791
  • [22] Crowns fit of the Procera's system in two types of cervicals limits.
    Camargo, AMA
    Fonseca, ACJM
    Melo, AB
    Bacigalupo, JC
    Salgado, JAP
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 169 - 169
  • [23] A COMPARISON OF THE MARGINAL FIT OF CROWNS FABRICATED WITH DIGITAL AND CONVENTIONAL METHODS
    Ng, Jonathan
    Ruse, Dorin
    Wyatt, Chris
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03): : 555 - 560
  • [24] Marginal fit of titanium crowns produced with two different systems
    Reich, S
    Kretschmar, W
    Brauner, H
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 267 - 267
  • [25] An in vitro study of the compressive load at fracture of Procera AllCeram crowns with varying thickness of veneer porcelain
    Webber, B
    McDonald, A
    Knowles, J
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (02): : 154 - 160
  • [26] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [27] MARGINAL FIT OF CASTABLE CERAMIC CROWNS
    HOLMES, JR
    SULIK, WD
    HOLLAND, GA
    BAYNE, SC
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (05): : 594 - 599
  • [28] MARGINAL FIT OF PORCELAIN JACKET CROWNS
    WALTON, TR
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : D198 - D198
  • [29] STUDIES ON THE MARGINAL FIT OF DICOR CROWNS
    BIENIEK, KW
    KUPPER, H
    RICHTER, EJ
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1989, 44 (10): : 783 - 784
  • [30] Evaluation of marginal and internal fit of lithium disilicate CAD-CAM crowns with different finish lines by using a micro-CT technique
    Rizonaki, Maria
    Jacquet, Wolfgang
    Bottenberg, Peter
    Depla, Lennert
    Boone, Matthieu
    De Coster, Peter J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 890 - 898