Structural and material mechanical properties of human vertebral cancellous bone

被引:81
|
作者
Nicholson, PHF
Cheng, XG
Lowet, G
Boonen, S
Davie, MWJ
Dequeker, J
Van der Perre, G
机构
[1] Katholieke Univ Leuven, Div Biomech & Engn Design, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Arthrit & Metab Bone Dis Res Unit, B-3001 Louvain, Belgium
[3] Robert Jones & Agnes Hunt Orthopaed Hosp, Charles Salt Res Ctr, Oswestry SY10 7AG, Shrops, England
关键词
cancellous bone; vertebra; mechanical properties; anisotropy; ultrasound;
D O I
10.1016/S1350-4533(97)00030-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The structural Young's modulus (i.e. that of the cancellous framework) was determined by non-destructive compressive mechanical testing in the the ee orthogonal ax es of 48 vertebral bone cubes. In addition, the material Young's modulus (i.e. of the trabeculae themselves) was estimated using an ultrasonic technique. Apparent and true density were determined by direct physical measurements. Significant mechanical anisotropy was observed: mean structural Young's modulus varied from 165 MPa in the supero-inferior direction to 43 MPa in the lateral direction. Structural Young's modulus correlated with apparent density, with power-law regression models giving the best correlations (r(2) = 0.52-0.88). Mechanical anisotropy increased as a function of decreasing apparent density (p < 0.001). Material Young's modulus was 10.0 +/- 1.3 GPa, and was negatively correlated with apparent density (p < 0.001). In multiple regression models, material Young's modulus was a significant independent predictor of structural Young's modulus only in the supero-inferior direction. The data suggest the presence of two effects in vertebral bone associated with decreasing apparent density and, by implication, bone loss in general: (a) increased mechanical anisotropy such that there is relative conservation of stiffness in the axial direction compared with the transverse directions; and (b) increased stiffness of the trabeculae themselves. (C) 1997 IPEM Published by Elsevier Science Ltd.
引用
收藏
页码:729 / 737
页数:9
相关论文
共 50 条
  • [31] QUANTITATIVE STRUCTURAL ANALYSIS OF HUMAN CANCELLOUS BONE
    MERZ, WA
    SCHENK, RK
    ACTA ANATOMICA, 1970, 75 (01): : 54 - &
  • [32] Mechanical failure begins preferentially near resorption cavities in human vertebral cancellous bone under compression
    Slyfield, C. R.
    Tkachenko, E. V.
    Fischer, S. E.
    Ehlert, K. M.
    Yi, I. H.
    Jekir, M. G.
    O'Brien, R. G.
    Keaveny, T. M.
    Hernandez, C. J.
    BONE, 2012, 50 (06) : 1281 - 1287
  • [33] Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone
    Teo, JCM
    Si-Hoe, KM
    Keh, JEL
    Teoh, SH
    CLINICAL BIOMECHANICS, 2006, 21 (03) : 235 - 244
  • [34] Mutual associations among microstructural, physical and mechanical properties of human cancellous bone
    Ding, M
    Odgaard, A
    Danielsen, CC
    Hvid, I
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (06): : 900 - 907
  • [35] Relationships among ultrasonic and mechanical properties of cancellous bone in human calcaneus in vitro
    Wear, Keith A.
    Nagaraja, Srinidhi
    Dreher, Maureen L.
    Sadoughi, Saghi
    Zhu, Shan
    Keaveny, Tony M.
    BONE, 2017, 103 : 93 - 101
  • [36] Influence of the fixation technique on the mechanical properties of human cancellous bone of the femoral head
    Fischer, Benjamin
    Hofmann, Alexander
    Kurz, Sascha
    Edel, Melanie
    Zajonz, Dirk Joerg
    Roth, Andreas
    Schleifenbaum, Stefan
    CLINICAL BIOMECHANICS, 2021, 82
  • [37] Material properties of cancellous bone in repetitive axial loading
    Linde, F.
    Hvid, I.
    Jensen, N.C.
    Engineering in Medicine, 1985, 14 (04): : 173 - 177
  • [38] Fractal properties of cancellous bone of the iliac crest in vertebral crush fracture
    Fazzalari, NL
    Parkinson, IH
    BONE, 1998, 23 (01) : 53 - 57
  • [39] Applicability of sheep and pig models for cancellous bone in human vertebral bodies
    Aslani, Farnaz Jabbary
    Hukins, David W. L.
    Shepherd, Duncan E. T.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H1) : 76 - 78
  • [40] Mechanical properties of ewe vertebral cancellous bone compared with histomorphometry and high-resolution computed tomography parameters
    Mitton, D
    Cendre, E
    Roux, JP
    Arlot, ME
    Peix, G
    Rumelhart, C
    Babot, D
    Meunier, PJ
    BONE, 1998, 22 (06) : 651 - 658