Dynamic behavior of cryogen spray cooling: Effects of spurt duration and spray distance

被引:54
|
作者
Aguilar, G
Wang, GX
Nelson, JS
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[2] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
[3] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
cooling selectivity; cryogen layer; cryogen droplets; droplet momentum; surface heat flux; skin cooling;
D O I
10.1002/lsm.10133
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery. Since optimization of CSC permits the safe use of higher light doses, which improves therapeutic outcome in many patients with superficial skin lesions, studies have focused on understanding spray-surface interactions and cooling dynamics. The objective of this study is to measure accurately temperature variations at the sprayed surface and the effects of spurt duration (Deltat) and nozzle-to- sprayed surface distance (L) on cooling dynamics during CSC. Study Design/Materials and Methods: A fast-response temperature measurement sensor is built using thin (20 mum) aluminum foil placed on top of a poly methylmethacrylate resin (Plexiglass((R))) with a 50 mum bead diameter thermocouple positioned in between. Liquid film residence time (t(r)) and minimum surface temperature (T-min) are systematically measured as a function of At and L. Results: Two distinct spray-surface interaction mechanisms are recognized. The transition between them occurs at a critical length L-c approximate to25-30 mm. Noticeable characteristics include: (1) for spurts at L < L-c, shorter t(r), and lower T-min are reached as compared to L > L-c, T-min is dependent on At and L, while tr is a function of Deltat only; (2) for spurts at L > L-c, T-min still depends on L but not on Deltat, while tr becomes a function of both Deltat and L. Finally, for all Deltat, t(r) reaches a maximum at L = 40 mm. Conclusions: Based on our results, a good choice to achieve low T-min and t(r) for the treatment of superficial skin lesions may be met by using Deltat of approximate to30-50 milliseconds and the shortest spray distance that is tolerable by the patient. Spurt durations (Deltat) of more than 30-50 milliseconds at spray distances (L) greater than L-c lead to higher T-min and longer t(r). These parameters may be appropriate for laser therapy of deeper targets. Lasers Surg. Med. 32:152-159, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [41] Radial and temporal variations in surface heat transfer during cryogen spray cooling
    Franco, W
    Liu, J
    Wang, GX
    Nelson, JS
    Aguilar, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 387 - 397
  • [42] Safety of cryogen spray cooling during pulsed laser treatment of selected dermatoses
    Nelson, JS
    Kimel, S
    LASERS IN SURGERY AND MEDICINE, 2000, 26 (01) : 2 - 3
  • [43] ON THE DYNAMIC BEHAVIOR OF SPRAY DRYERS
    CLEMENT, KH
    HALLSTROM, A
    DICH, HC
    LE, CM
    MORTENSEN, J
    THOMSEN, HA
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1991, 69 (03): : 245 - 252
  • [44] Intermittent cryogen spray cooling coupled with cold air jet for heat transfer enhancement and cryogen saving of laser dermatology
    Qenawy, Mohamed
    Chen, Yiqi
    Wang, Junfeng
    Tian, Jiameng
    Chen, Bin
    PHYSICS OF FLUIDS, 2024, 36 (02)
  • [45] Parametric effect investigation on surface heat transfer performances during cryogen spray cooling
    Tian, Jia-Meng
    Chen, Bin
    Zhou, Zhi-Fu
    APPLIED THERMAL ENGINEERING, 2018, 143 : 767 - 776
  • [46] Numerical simulation of cryogen spray cooling by a three-dimensional hybrid vortex method
    Wang, Rui
    Chen, Bin
    Wang, Xin-Sheng
    APPLIED THERMAL ENGINEERING, 2017, 119 : 319 - 330
  • [47] Psoriasis treatment with a 450 μs pulsed dye laser in combination with cryogen spray cooling
    Kelly, KM
    Nelson, JS
    Weinstein, G
    McMillan, K
    LASERS IN SURGERY AND MEDICINE, 2003, : 66 - 66
  • [48] Infrared imaging of 2-D temperature distribution during cryogen spray cooling
    Choi, B
    Welch, AJ
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06): : 669 - 675
  • [49] Influence of cryogen spray cooling parameters on the heat extraction rate from a sprayed surface
    Karapetian, E
    Aguilar, G
    Lavernia, EJ
    Nelson, JS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XII, 2002, 4609 : 83 - 93
  • [50] Analysis of epidermal/dermal temperature changes according to the different cryogen spray cooling conditions
    Jo, Jung Ho
    Jo, Su Hyun
    Lee, Ju Hwan
    Kim, Ga Young
    Kim, Sung Min
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S11 - S16