Dynamic behavior of cryogen spray cooling: Effects of spurt duration and spray distance

被引:54
|
作者
Aguilar, G
Wang, GX
Nelson, JS
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[2] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
[3] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
cooling selectivity; cryogen layer; cryogen droplets; droplet momentum; surface heat flux; skin cooling;
D O I
10.1002/lsm.10133
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery. Since optimization of CSC permits the safe use of higher light doses, which improves therapeutic outcome in many patients with superficial skin lesions, studies have focused on understanding spray-surface interactions and cooling dynamics. The objective of this study is to measure accurately temperature variations at the sprayed surface and the effects of spurt duration (Deltat) and nozzle-to- sprayed surface distance (L) on cooling dynamics during CSC. Study Design/Materials and Methods: A fast-response temperature measurement sensor is built using thin (20 mum) aluminum foil placed on top of a poly methylmethacrylate resin (Plexiglass((R))) with a 50 mum bead diameter thermocouple positioned in between. Liquid film residence time (t(r)) and minimum surface temperature (T-min) are systematically measured as a function of At and L. Results: Two distinct spray-surface interaction mechanisms are recognized. The transition between them occurs at a critical length L-c approximate to25-30 mm. Noticeable characteristics include: (1) for spurts at L < L-c, shorter t(r), and lower T-min are reached as compared to L > L-c, T-min is dependent on At and L, while tr is a function of Deltat only; (2) for spurts at L > L-c, T-min still depends on L but not on Deltat, while tr becomes a function of both Deltat and L. Finally, for all Deltat, t(r) reaches a maximum at L = 40 mm. Conclusions: Based on our results, a good choice to achieve low T-min and t(r) for the treatment of superficial skin lesions may be met by using Deltat of approximate to30-50 milliseconds and the shortest spray distance that is tolerable by the patient. Spurt durations (Deltat) of more than 30-50 milliseconds at spray distances (L) greater than L-c lead to higher T-min and longer t(r). These parameters may be appropriate for laser therapy of deeper targets. Lasers Surg. Med. 32:152-159, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [31] Effects of droplet velocity, diameter, and film height on heat removal during cryogen spray cooling
    Pikkula, BM
    Tunnell, JW
    Chang, DW
    Anvari, B
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (08) : 1131 - 1140
  • [32] Evaluation of cryogen spray cooling exposure on in vitro model human skin
    Kao, BS
    Kelly, KM
    Aguilar, G
    Hosaka, Y
    Barr, RJ
    Nelson, JS
    LASERS IN SURGERY AND MEDICINE, 2004, 34 (02) : 146 - 154
  • [33] Spray and cooling dynamics of cryogen sprays impinging on a human skin model
    Franco, Walfre
    Vu, Henry
    Jia, Wangcun
    Nelson, J. Stuart
    Aguilar, Guillermo
    PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 1, 2007, : 815 - 821
  • [34] Cryogen spray cooling:: Influence of droplet velocity on epidermal protection in vivo
    Pikkula, BM
    Dai, TH
    Chang, D
    Anyari, B
    LASERS IN SURGERY AND MEDICINE, 2003, : 2 - 2
  • [35] Comparative analysis of single droplet evaporation models in Cryogen Spray Cooling
    Xin, Hui
    Zhou, Zhi-Fu
    Chen, Bin
    Wang, Guo-Xiang
    Wang, Yue-She
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (04): : 653 - 656
  • [36] Jet impingement modeling of cryogen spray cooling: Analysis of 2-D cryogen temperature distribution
    Choi, B
    Welch, AJ
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION THERAPEUTICS, AND SYSTEMS XI, 2001, 4244 : 93 - 104
  • [37] Effects of mass flow rate and droplet velocity on surface heat flux during cryogen spray cooling
    Karapetian, E
    Aguilar, G
    Kimel, S
    Lavernia, EJ
    Nelson, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01): : N1 - N6
  • [38] Evaluation of tissue effects after continuous versus shorter multiple intermittent cryogen spray cooling exposure
    Tuqan, AT
    Kelly, KM
    Aguilar, G
    Ramirez, J
    Sun, CH
    Cassarino, D
    Derienzo, D
    Barr, RJ
    Nelson, JS
    LASERS IN SURGERY AND MEDICINE, 2004, : 2 - 2
  • [39] Effects of relative humidity on laser light transmittance during cryogen spray cooling of in vitro skin phantoms
    Ramirez-San-Juan, JC
    Choi, B
    Franco, W
    Nelson, JS
    Aguilar, G
    Photonic Therapeutics and Diagnostics, 2005, 5686 : 154 - 158
  • [40] Experimental Study on Heat Transfer of Cryogen Spray Cooling Coupled Air Jet
    Guo, Xiao-Xing
    Zhou, Zhi-Fu
    Chen, Bin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (06): : 1452 - 1456