Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

被引:4
|
作者
Haggerty, Ryan P. [1 ]
Sarin, Pankaj [1 ]
Berar, Jean-Francois [2 ,3 ]
Apostolov, Zlatomir D. [1 ]
Kriven, Waltraud M. [1 ]
机构
[1] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[2] UIF, Grenoble, France
[3] Inst Neel CNRS, Grenoble, France
关键词
HIGH-RESOLUTION; GEOMETRY; SYSTEM;
D O I
10.1107/S0021889810006400
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided. (c) 2010 International Union of Crystallography Printed in Singapore - all rights reserved
引用
收藏
页码:560 / 569
页数:10
相关论文
共 50 条
  • [41] PERFORMANCE OF A POSITION-SENSITIVE BAR DETECTOR
    KARP, JS
    MUEHLLEHNER, G
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P47 - P47
  • [42] Position-sensitive CZT detector module
    Matteson, JL
    Duttweiler, F
    Huszar, GL
    Leblanc, PC
    Skelton, RT
    Stephan, EA
    Hink, PL
    Dowkontt, PF
    Slavis, KR
    Tümer, TO
    Kravis, SD
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND APPLICATIONS, 1998, 3446 : 192 - 201
  • [43] Amorphous silicon position-sensitive detector
    Mochiki, Koh-ichi
    Hasegawa, Ken-ichi
    Namatame, Shuji
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 640 - 644
  • [44] PROPOSAL FOR A POSITION-SENSITIVE PHOTOMULTIPLIER DETECTOR
    PRYDZ, S
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (02): : 189 - 190
  • [45] A COMPACT POSITION-SENSITIVE DETECTOR FOR PET
    WATANABE, M
    OMURA, T
    KYUSHIMA, H
    HASEGAWA, Y
    YAMASHITA, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1090 - 1094
  • [46] POSITION-SENSITIVE SUPERCONDUCTING RADIATION DETECTOR
    VASILEVICH, AF
    KLYACHIN, NA
    LYAPIDEVSKII, VK
    PEREZHOGIN, VB
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (02) : 376 - 377
  • [47] RADIAL POSITION-SENSITIVE SEMICONDUCTOR DETECTOR
    AMOV, B
    DZHAKOV, A
    OSIPENKO, BP
    PENTSYA, E
    SANDUKOVSKII, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (03) : 561 - 563
  • [48] A NEW TYPE OF POSITION-SENSITIVE DETECTOR
    AGORITSAS, V
    NEMOZ, C
    KURODA, K
    SILLOU, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (03): : 437 - 441
  • [49] SI(LI) POSITION-SENSITIVE DETECTOR
    GIGANTE, JR
    NUCLEAR INSTRUMENTS & METHODS, 1973, 111 (02): : 345 - 353
  • [50] PERFORMANCE OF A POSITION-SENSITIVE SCINTILLATION DETECTOR
    KARP, JS
    MUEHLLEHNER, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (07): : 643 - 655