Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

被引:4
|
作者
Haggerty, Ryan P. [1 ]
Sarin, Pankaj [1 ]
Berar, Jean-Francois [2 ,3 ]
Apostolov, Zlatomir D. [1 ]
Kriven, Waltraud M. [1 ]
机构
[1] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[2] UIF, Grenoble, France
[3] Inst Neel CNRS, Grenoble, France
关键词
HIGH-RESOLUTION; GEOMETRY; SYSTEM;
D O I
10.1107/S0021889810006400
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided. (c) 2010 International Union of Crystallography Printed in Singapore - all rights reserved
引用
收藏
页码:560 / 569
页数:10
相关论文
共 50 条
  • [31] X-RAY-DIFFRACTION TEXTURE ANALYSIS WITH A POSITION-SENSITIVE DETECTOR
    WCISLAK, L
    BUNGE, HJ
    NAUERGERHARDT, CU
    ZEITSCHRIFT FUR METALLKUNDE, 1993, 84 (07): : 479 - 493
  • [32] A NEW LINEAR POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRON POWDER DIFFRACTOMETRY
    SCHAFER, W
    JANSEN, E
    ELF, F
    WILL, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (JUN) : 159 - 166
  • [33] A position-sensitive alpha detector using a thin plastic scintillator combined with a position-sensitive photomultiplier tube
    Yamamoto, S
    Iida, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 387 - 393
  • [34] FAST TEXTURE MEASUREMENTS USING A POSITION-SENSITIVE DETECTOR
    JENSEN, DJ
    LEFFERS, T
    TEXTURES AND MICROSTRUCTURES, 1989, 10 (04): : 361 - 373
  • [35] Development of a position-sensitive detector for UCN Using CCD
    ICEPP, University of Tokyo
    不详
    不详
    KURRI Prog Rep, 2006, (170):
  • [36] Scanning transmission microscopy using a position-sensitive detector
    Ayres, Mark R.
    McLeod, Robert R.
    APPLIED OPTICS, 2006, 45 (33) : 8410 - 8418
  • [37] A NEW DIFFRACTOMETER USING A CURVED POSITION-SENSITIVE DETECTOR AND ITS APPLICATIONS TO X-RAY CRYSTALLOGRAPHY
    IZUMI, T
    KURIHAMA, T
    NITTA, J
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (DEC) : 470 - 475
  • [38] A LARGE POSITION-SENSITIVE NEUTRON DETECTOR
    NETTER, P
    LASSEN, L
    SCHRECK, R
    GEMMEKE, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 165 - 174
  • [39] Measurement and analysis of field-induced crystallographic texture using curved position-sensitive diffraction detectors
    Simons, Hugh
    Daniels, John E.
    Studer, Andrew J.
    Jones, Jacob L.
    Hoffman, Mark
    JOURNAL OF ELECTROCERAMICS, 2014, 32 (04) : 283 - 291
  • [40] Measurement and analysis of field-induced crystallographic texture using curved position-sensitive diffraction detectors
    Hugh Simons
    John E. Daniels
    Andrew J. Studer
    Jacob L. Jones
    Mark Hoffman
    Journal of Electroceramics, 2014, 32 : 283 - 291