Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit

被引:20
|
作者
Zompanti, Alessandro [1 ]
Sabatini, Anna [1 ]
Grasso, Simone [2 ]
Pennazza, Giorgio [1 ]
Ferri, Giuseppe [3 ]
Barile, Gianluca [3 ]
Chello, Massimo [4 ]
Lusini, Mario [4 ]
Santonico, Marco [2 ]
机构
[1] Campus Biomed Univ Rome, Dept Engn, Unit Elect Sensor Syst, I-00128 Rome, Italy
[2] Campus Biomed Univ Rome, Dept Sci & Technol Humans & Environm, Unit Elect Sensor Syst, I-00128 Rome, Italy
[3] Univ Aquila, Dept Ind & Informat Engn & Econ, I-67100 Laquila, Italy
[4] Campus Biomed Univ Rome, Dept Med, Unit Cardiol, I-00128 Rome, Italy
关键词
wearable sensors and devices; wearable monitoring systems; wearable healthcare electrocardiography; wireless ECG monitoring systems; electronics for biosignals and biopotentials; electronic interfaces and embedded sensor systems for biomedical application; dry electrodes; capacitive coupling electrodes;
D O I
10.3390/s21082777
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Development and wearer trial of ECG-garment with textile-based dry electrodes
    Fink, Paula Luise
    Sayem, Abu Sadat Muhammad
    Teay, Siew Hon
    Ahmad, Faisal
    Shahariar, Hasan
    Albarbar, Alhussein
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 328
  • [32] Two-Electrode Electrocardiogram Acquisition Circuit With On-chip Driven-right-leg
    Lim, Sungkyu
    Lee, Hi-Deok
    Ko, Hyoungho
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 6 - 6
  • [33] Test-driven development for generated portable Java']Javascript apps
    Bouragadi, Noury
    Mason, Dave
    SCIENCE OF COMPUTER PROGRAMMING, 2018, 161 : 2 - 17
  • [34] Test Driven Development for Device Drivers and Rapid Hardware Prototyping
    Eschweiler, Dominic
    Lindenstruth, Volker
    2015 IEEE EIGHTH INTERNATIONAL CONFERENCE ON SOFTWARE TESTING, VERIFICATION AND VALIDATION WORKSHOPS (ICSTW), 2015,
  • [35] DEVELOPMENT OF STANDARD TEST METHODS FOR EVALUATING DEFIBRILLATION RECOVERY CHARACTERISTICS OF DISPOSABLE ECG ELECTRODES
    SCHOENBERG, AA
    BOOTH, HE
    LYON, PC
    MEDICAL INSTRUMENTATION, 1979, 13 (05): : 259 - &
  • [36] Development of portable device for transmitting respiratory & ECG gating in list-mode PET data acquisition
    Kim, Joong Il
    Park, Hae-Jeong
    Kim, Tae-Sung
    Yun, Mijin
    Lee, Jong Doo
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 874 - +
  • [37] EEG Acquisition System based on Active Electrodes with Common-Mode Interference Suppression by Driving Right Leg Circuit
    Guermandi, Marco
    Bigucci, Alessandro
    Scarselli, Eleonora Franchi
    Guerrieri, Roberto
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3169 - 3172
  • [38] Development of a portable test device for assessing on-site floor slipperiness:: an interim report
    Grönqvist, R
    Hirvonen, M
    Rajamäki, E
    APPLIED ERGONOMICS, 2001, 32 (02) : 163 - 171
  • [39] Performance Assessment of Microneedle Dry and Wet Gel Electrodes Using a Dual-Channel, Single Lead Wearable ECG Device
    Singh, Om Prakash
    Hu, Yuan
    Bocchino, Andrea
    Guillerm, Theo
    O'Mahony, Conor
    2022 IEEE 21ST MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (IEEE MELECON 2022), 2022, : 737 - 740
  • [40] Development of a novel portable test device to measure the tribological behaviour of shoe interactions with tennis courts
    Ura, Daniel
    Carre, Matt
    ENGINEERING OF SPORT 11, 2016, 147 : 550 - 555