Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit

被引:20
|
作者
Zompanti, Alessandro [1 ]
Sabatini, Anna [1 ]
Grasso, Simone [2 ]
Pennazza, Giorgio [1 ]
Ferri, Giuseppe [3 ]
Barile, Gianluca [3 ]
Chello, Massimo [4 ]
Lusini, Mario [4 ]
Santonico, Marco [2 ]
机构
[1] Campus Biomed Univ Rome, Dept Engn, Unit Elect Sensor Syst, I-00128 Rome, Italy
[2] Campus Biomed Univ Rome, Dept Sci & Technol Humans & Environm, Unit Elect Sensor Syst, I-00128 Rome, Italy
[3] Univ Aquila, Dept Ind & Informat Engn & Econ, I-67100 Laquila, Italy
[4] Campus Biomed Univ Rome, Dept Med, Unit Cardiol, I-00128 Rome, Italy
关键词
wearable sensors and devices; wearable monitoring systems; wearable healthcare electrocardiography; wireless ECG monitoring systems; electronics for biosignals and biopotentials; electronic interfaces and embedded sensor systems for biomedical application; dry electrodes; capacitive coupling electrodes;
D O I
10.3390/s21082777
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Reduction of power line interference using active electrodes and a driven-right-leg circuit in electroencephalographic recording with a minimum number of electrodes
    Nonclercq, A
    Mathys, P
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2247 - 2250
  • [22] Quantification of Motion Artifact Rejection Due to Active Electrodes and Driven-Right-Leg Circuit in Spike Detection Algorithms
    Nonclercq, Antoine
    Mathys, Pierre
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (11) : 2746 - 2752
  • [23] Development and applications of a portable erosion test device
    Anwar, Tariqul
    Huang, Jie
    Johnson, Drew W.
    FROM FUNDAMENTALS TO APPLICATIONS IN GEOTECHNICS, 2015, : 462 - 469
  • [24] Can Driven-Right-Leg Circuits Increase Interference in ECG Amplifiers?
    Gomez-Clapers, J.
    Serrano-Finetti, E.
    Casanella, R.
    Pallas-Areny, R.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4780 - 4783
  • [25] A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes
    Yan, Long
    Yoo, Hoi-Jun
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2010, 10 (04) : 300 - 308
  • [26] Development of Flexible Dry ECG Electrodes Based on MWCNT/PDMS Composite
    Chlaihawi, Amer Abdulmahdi
    Narakathu, Binu Baby
    Emamian, Sepehr
    Eshkeiti, Ali
    Reddy, Sai Guruva Avuthu
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    2015 IEEE SENSORS, 2015, : 221 - 224
  • [27] A Low Cost Mobile ECG Monitoring Device Using Two Active Dry Electrodes
    Tai Le
    Huy-Dung Han
    Thai-Hoc Hoang
    Vu Cong Nguyen
    Cuong Kieu Nguyen
    2016 IEEE SIXTH INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND ELECTRONICS (ICCE), 2016, : 271 - 276
  • [28] Development of portable ECG Measurement Device and PC Software for Automatic ST Analysis
    Jeong, Gu-Young
    Yoon, Myoung-Jong
    Yu, Kee-Ho
    Kwon, Tae-Kyu
    INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2010), 2010, : 1171 - 1174
  • [29] Transferring an Artifact Handling System into a Mobile Long-term ECG Device with Dry Electrodes
    Kirst, Malte
    Lamparth, Stefan
    Fuhrhop, Silvester
    Ottenbacher, Joerg
    Kunze, Christophe
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 942 - 945
  • [30] Development of a plasma separation system for a portable blood test device
    Kuroda, Chiaki
    Ohki, Yoshimichi
    Ashiba, Hiroki
    Fujimaki, Makoto
    Awazu, Koichi
    Tanaka, Torahiko
    Makishima, Makoto
    IEEJ Transactions on Sensors and Micromachines, 2015, 135 (05) : 152 - 157