Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit

被引:20
|
作者
Zompanti, Alessandro [1 ]
Sabatini, Anna [1 ]
Grasso, Simone [2 ]
Pennazza, Giorgio [1 ]
Ferri, Giuseppe [3 ]
Barile, Gianluca [3 ]
Chello, Massimo [4 ]
Lusini, Mario [4 ]
Santonico, Marco [2 ]
机构
[1] Campus Biomed Univ Rome, Dept Engn, Unit Elect Sensor Syst, I-00128 Rome, Italy
[2] Campus Biomed Univ Rome, Dept Sci & Technol Humans & Environm, Unit Elect Sensor Syst, I-00128 Rome, Italy
[3] Univ Aquila, Dept Ind & Informat Engn & Econ, I-67100 Laquila, Italy
[4] Campus Biomed Univ Rome, Dept Med, Unit Cardiol, I-00128 Rome, Italy
关键词
wearable sensors and devices; wearable monitoring systems; wearable healthcare electrocardiography; wireless ECG monitoring systems; electronics for biosignals and biopotentials; electronic interfaces and embedded sensor systems for biomedical application; dry electrodes; capacitive coupling electrodes;
D O I
10.3390/s21082777
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Capacitive driven-right-leg circuit design
    Alejandro Haberman, Marcelo
    Mario Spinelli, Enrique
    Andres Garcia, Pablo
    Nicolas Guerrero, Federico
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2015, 17 (02) : 115 - 126
  • [2] An ECG measurement IC using driven-right-leg circuit
    Wong, Alex
    Pun, Kong-Pang
    Zhang, Yuan-Ting
    Choy, Chiu-Sing
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 345 - +
  • [3] Non-contact Biopotential Amplifier with Capacitive Driven Right Leg Circuit
    Cindric, Dino
    Klaic, Luka
    Stanesic, Antonio
    Cifrek, Mario
    MEDICON 2023 AND CMBEBIH 2023, VOL 1, 2024, 93 : 180 - 188
  • [4] Capacitive Driven-right-leg Grounding in Indirect-contact ECG Measurement
    Lim, Yong Gyu
    Chung, Gih Sung
    Park, Kwang Suk
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1250 - 1253
  • [5] High gain driven right leg circuit for dry electrode systems
    Guerrero, Federico N.
    Spinelli, Enrique
    MEDICAL ENGINEERING & PHYSICS, 2017, 39 : 117 - 122
  • [6] ECG front-end subsystem with the driven-right-leg circuit
    School of Microelectronics, Xidian Univ., Xi'an
    710071, China
    Xi'an Dianzi Keji Daxue Xuebao, 4 (166-171):
  • [7] A Digital Driven Right Leg Circuit
    Haberman, Marcelo
    Spinelli, Enrique
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6559 - 6562
  • [8] MD-Link: A portable ECG monitoring device with active dry electrodes and its validation
    Tai Le
    Le-Lan Tran
    Thai-Hoc Hoang
    Huy-Dung Han
    Ngoc T Phan
    Vu Cong Nguyen
    Tuan A Nguyen
    Nga T T Pham
    Hung Cao
    Cuong Kieu Nguyen
    2019 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC 2019), 2019,
  • [9] Development of portable ECG measurement device
    Electronic Information Institute, Hangzhou Dianzi University, Hangzhou 310018, China
    Yi Qi Yi Biao Xue Bao, 2007, SUPPL. 5 (60-62):
  • [10] Active capacitive ECG system with all-digital "driven right leg" common mode suppression
    Torfs, Tom
    Patel, Aakash
    Castro, Ivan D.
    2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,