Dual-Energy Computed Tomography Imaging of the Aorta After Endovascular Repair of Abdominal Aortic Aneurysm

被引:20
|
作者
Laks, Shaked [1 ]
Macari, Michael [1 ]
Chandarana, Hersh [1 ]
机构
[1] NYU, Dept Radiol, Langone Med Ctr, Sch Med, New York, NY 10016 USA
关键词
STENT-GRAFT; MULTIDETECTOR CT; HELICAL CT; EUROSTAR EXPERIENCE; DELAYED PHASE; TIN-FILTER; FOLLOW-UP; 80; KVP; ENDOLEAKS; ANGIOGRAPHY;
D O I
10.1053/j.sult.2010.05.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Endovascular repair is increasingly considered a less-invasive alternative to open repair of abdominal aortic aneurysm. However, there are still many potential complications of endovascular repair, including endoleaks, graft migration, thrombosis, and fistula formation. Endo leak is the most common complication for which these patients undergo long-term imaging surveillance. Most centers acquire computed tomographic (CT) data before contrast administration and during an arterial and delayed phase of aortic enhancement after the administration of intravenous contrast material to optimize detection of endoleaks. Although this technique works well, the downside is significant patient radiation exposure. Although the carcinogenic risk of ionizing radiation because of CT exposure is low, it has been linked to an increase in the lifelong risk of developing fatal cancers. Furthermore, this risk is cumulative and increases with multiple radiation exposure, as is true in surveillance after endovascular repair. As a result, considerable research is being performed to optimize CT protocols in an effort to decrease radiation dose. One such approach is to image these patients with recently introduced dual source dual-energy CT system. Using this technique, virtual noncontrast data may be generated from a postcontrast acquisition which may obviate the routine acquisition of noncontrast acquisition, thus decreasing radiation dose. In this article, we discuss the role of dual energy CT imaging in evaluation of patients after endovascular repair of abdominal aortic aneurysm. Semin Ultrasound CT MRI 31:292-300 (C) 2010 Elsevier Inc. All rights reserved
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [1] Dual-energy computed tomography after endovascular aortic aneurysm repair: The role of hard plaque imaging for endoleak detection
    R. Müller-Wille
    T. Borgmann
    W. A. Wohlgemuth
    F. Zeman
    K. Pfister
    E. M. Jung
    P. Heiss
    A. G. Schreyer
    B. Krauss
    C. Stroszczynski
    C. Dornia
    European Radiology, 2014, 24 : 2449 - 2457
  • [2] Dual-energy computed tomography after endovascular aortic aneurysm repair: The role of hard plaque imaging for endoleak detection
    Mueller-Wille, R.
    Borgmann, T.
    Wohlgemuth, W. A.
    Zeman, F.
    Pfister, K.
    Jung, E. M.
    Heiss, P.
    Schreyer, A. G.
    Krauss, B.
    Stroszczynski, C.
    Dornia, C.
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2449 - 2457
  • [3] Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Braegelmann, A.
    Bunck, A.
    Donas, K.
    Kasprzak, B.
    Maintz, D.
    Heindel, W.
    Seifarth, H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (04): : 351 - 357
  • [4] Dual-energy Computed Tomography Imaging of the Aorta
    Vlahos, Ioannis
    Godoy, Myrna C. B.
    Naidich, David P.
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 289 - 300
  • [5] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [6] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Vitaliano Buffa
    Antonio Solazzo
    Valeria D’Auria
    Alessandra Del Prete
    Andrea Vallone
    Monica Luzietti
    Manuela Madau
    Roberto Grassi
    Vittorio Miele
    La radiologia medica, 2014, 119 : 934 - 941
  • [7] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [8] Imaging after endovascular repair of abdominal aortic aneurysm
    J. Golzarian
    Abdominal Imaging, 2003, 28 : 0236 - 0243
  • [9] Imaging after endovascular repair of abdominal aortic aneurysm
    Golzarian, J
    ABDOMINAL IMAGING, 2002, 28 (02): : 236 - 243
  • [10] The utility of dual-energy computed tomography in abdominal imaging
    Del Gaizo, Andrew J.
    Silva, Alvin C.
    Hara, Amy K.
    APPLIED RADIOLOGY, 2014, 43 (01) : 12 - +