Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair

被引:4
|
作者
Braegelmann, A. [1 ]
Bunck, A. [1 ,2 ]
Donas, K. [3 ]
Kasprzak, B. [3 ]
Maintz, D. [1 ,2 ]
Heindel, W. [1 ]
Seifarth, H. [1 ]
机构
[1] Univ Klinikum Munster, Inst Klin Radiol, D-48149 Munster, Germany
[2] Univ Klinikum Koln, Inst & Poliklin Radiol Diagnost, Cologne, Germany
[3] Univ Klinikum Munster, Klin Vaskulare & Endovaskulare Chirurg, D-48149 Munster, Germany
关键词
aorta; CT angiography; aneurysm; CONTRAST-ENHANCED ULTRASOUND; COMPUTED-TOMOGRAPHY; ENDOLEAK DETECTION; CLASSIFICATION; SURVEILLANCE; MANAGEMENT; SOCIETY; EVAR;
D O I
10.1055/s-0032-1330447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigates the dual-energy procedure for postoperative CT follow-up scans after endovascularly treated abdominal aortic aneurysms. The procedure is analyzed with respect to its sensitivity and specificity as well as the associated radiation exposure. Materials and Methods: 51 examinations were carried out on 47 patients between February 2009 and March 2010. For each patient, a non-enhanced, an arterial and a venous scan were conducted, the latter two using the dual-energy technology. Virtual images for the non-enhanced phase were reconstructed from the data taken in the venous phase. Protocol A, the reference standard, consisted of non-enhanced images and images of the arterial and venous phase. In protocol B, standard non-enhanced images were replaced by the reconstructed virtual non-enhanced images. Protocol C consisted only of virtual non-enhanced and 80 kV images taken during the venous phase. All data was anonymized and evaluated by two independent radiologists. For protocol C, sensitivity, specificity, negative and positive predictive values were computed. The effective radiation dosage was determined for each scan. Results: All endoleaks identified in protocol A were found using protocols B and C. For protocol C, the sensitivity and negative predictive value were 100%, the specificity was 94.1%, and the positive predictive value was 89.5%. Compared to protocol A, protocol C reduces the radiation exposure by 62.45%. Conclusion: A scan protocol consisting of virtual non-enhanced images as well as 80 kV images taken during the venous phase was found to be a reliable alternative method for diagnosing endoleaks, while reducing the radiation exposure by 62.45%.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [1] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [2] Endovascular Abdominal Aortic Aneurysm Repair: Nonenhanced Volumetric CT for Follow-up
    Bley, Thorsten A.
    Chase, Peter J.
    Reeder, Scott B.
    Francois, Christopher J.
    Shinki, Kazuhiko
    Tefera, Girma
    Ranallo, Frank N.
    Grist, Thomas M.
    Pozniak, Myron
    RADIOLOGY, 2009, 253 (01) : 253 - 262
  • [3] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Vitaliano Buffa
    Antonio Solazzo
    Valeria D’Auria
    Alessandra Del Prete
    Andrea Vallone
    Monica Luzietti
    Manuela Madau
    Roberto Grassi
    Vittorio Miele
    La radiologia medica, 2014, 119 : 934 - 941
  • [4] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [5] Clinical significance of endoleak detected on follow-up CT after endovascular repair of abdominal aortic aneurysm
    Hong, Cheng
    Heiken, Jay P.
    Sicard, Gregorio A.
    Pilgram, Thomas K.
    Bae, Kyongtae T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (03) : 808 - 813
  • [6] Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair
    Wever, JJ
    Blankensteijn, JD
    Mali, WPTM
    Eikelboom, BC
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 177 - 182
  • [7] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [8] Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair
    Spanos, Konstantinos
    Karathanos, Christos
    Athanasoulas, Athanasios
    Sapeltsis, Vasileios
    Giannoukas, Athanasios D.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (04): : 611 - 618
  • [9] Follow-up of aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Bravo Soberon, Alberto
    Marti de Garcia, Milagros
    Garzon Moll, Gonzalo
    Rodriguez Vigil, Beatriz
    Allona Krauel, Maria
    Alvarez-Sala Walter, Rodolfo
    ANNALS OF VASCULAR SURGERY, 2008, 22 (04) : 559 - 563
  • [10] Follow-Up Compliance After Endovascular Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P.
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 809 - 809