Dual-Energy Computed Tomography Imaging of the Aorta After Endovascular Repair of Abdominal Aortic Aneurysm

被引:20
|
作者
Laks, Shaked [1 ]
Macari, Michael [1 ]
Chandarana, Hersh [1 ]
机构
[1] NYU, Dept Radiol, Langone Med Ctr, Sch Med, New York, NY 10016 USA
关键词
STENT-GRAFT; MULTIDETECTOR CT; HELICAL CT; EUROSTAR EXPERIENCE; DELAYED PHASE; TIN-FILTER; FOLLOW-UP; 80; KVP; ENDOLEAKS; ANGIOGRAPHY;
D O I
10.1053/j.sult.2010.05.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Endovascular repair is increasingly considered a less-invasive alternative to open repair of abdominal aortic aneurysm. However, there are still many potential complications of endovascular repair, including endoleaks, graft migration, thrombosis, and fistula formation. Endo leak is the most common complication for which these patients undergo long-term imaging surveillance. Most centers acquire computed tomographic (CT) data before contrast administration and during an arterial and delayed phase of aortic enhancement after the administration of intravenous contrast material to optimize detection of endoleaks. Although this technique works well, the downside is significant patient radiation exposure. Although the carcinogenic risk of ionizing radiation because of CT exposure is low, it has been linked to an increase in the lifelong risk of developing fatal cancers. Furthermore, this risk is cumulative and increases with multiple radiation exposure, as is true in surveillance after endovascular repair. As a result, considerable research is being performed to optimize CT protocols in an effort to decrease radiation dose. One such approach is to image these patients with recently introduced dual source dual-energy CT system. Using this technique, virtual noncontrast data may be generated from a postcontrast acquisition which may obviate the routine acquisition of noncontrast acquisition, thus decreasing radiation dose. In this article, we discuss the role of dual energy CT imaging in evaluation of patients after endovascular repair of abdominal aortic aneurysm. Semin Ultrasound CT MRI 31:292-300 (C) 2010 Elsevier Inc. All rights reserved
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [21] Non-contrast Computed Tomography is Comparable to Contrast-enhanced Computed Tomography for Aortic Volume Analysis after Endovascular Abdominal Aortic Aneurysm Repair
    Nambi, P.
    Sengupta, R.
    Krajcer, Z.
    Muthupillai, R.
    Strickman, N.
    Cheong, B. Y. C.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 41 (04) : 460 - 466
  • [22] Complications in Computed Tomography Angiography Following Thoracic Endovascular Aneurysm Repair and Endovascular Aortic Aneurysm Repair
    Rabiee, Parham
    Pouraliakbar, Hamidreza
    Kuhikheyli, Mohsen Palangi
    Dastmardi, Maedeh
    Motevalli, Marzieh
    Soleimani, Khadijeh
    IRANIAN HEART JOURNAL, 2024, 25 (03): : 51 - 57
  • [24] Abdominal Aortic Aneurysm evolution after endovascular repair
    Lev, G.
    Mendiz, O.
    Valdivieso, L.
    Carlos, F.
    Villagra, L.
    Scaglia, J.
    Mollon, P.
    CIRCULATION, 2008, 118 (12) : E427 - E427
  • [25] Ruptured abdominal aortic aneurysm after endovascular repair
    Bernhard, VM
    Mitchell, RS
    Matsumura, JS
    Brewster, DC
    Decker, M
    Lamparello, P
    Raithel, D
    Collin, J
    JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) : 1155 - 1162
  • [26] Surveillance After Endovascular Abdominal Aortic Aneurysm Repair
    Tse, Donald M. L.
    Tapping, Charles R.
    Patel, Rafiuddin
    Morgan, Robert
    Bratby, Mark J.
    Anthony, Susan
    Uberoi, Raman
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (04) : 875 - 888
  • [27] Surveillance After Endovascular Abdominal Aortic Aneurysm Repair
    Donald M. L. Tse
    Charles R. Tapping
    Rafiuddin Patel
    Robert Morgan
    Mark J. Bratby
    Susan Anthony
    Raman Uberoi
    CardioVascular and Interventional Radiology, 2014, 37 : 875 - 888
  • [28] Endoleak after endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    Faruqi, RM
    Sawhney, R
    Reilly, LM
    Kerlan, RB
    Canto, CJ
    Lukaszewicz, GC
    LaBerge, JM
    Wilson, MW
    Gordon, RL
    Wall, SD
    Rapp, J
    Messina, LM
    JOURNAL OF VASCULAR SURGERY, 2001, 34 (01) : 98 - 105
  • [29] Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine Overlay
    Ascenti, Giorgio
    Mazziotti, Silvio
    Lamberto, Salvatore
    Bottari, Antonio
    Caloggero, Simona
    Racchiusa, Sergio
    Mileto, Achille
    Scribano, Emanuele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1408 - 1414
  • [30] Ruptured abdominal aortic aneurysm after endovascular aortic aneurysm repair thrombosis
    Victory, Jesse
    Rizvi, Syed Ali
    Ascher, Enrico
    Hingorani, Anil
    VASCULAR, 2017, 25 (03) : 333 - 335