A microfabricated flow-through cell with parallel-opposed electrodes for recycling amperometric detection

被引:15
|
作者
Brooks, SA [1 ]
Kennedy, RT [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1997年 / 436卷 / 1-2期
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0022-0728(97)00224-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow-through recycling electrochemical detectors with dual Au electrodes were fabricated using micromachining techniques. Detector cells contained two microband electrodes that were 50 mu m wide by 3-5 mm long separated by a 5 or 10 mu m gap in a parallel-opposed configuration. One electrode was defined in the bottom of a channel which was etched into the surface of a Si wafer while the other electrode was defined on a glass substrate. The depth of the channel defined the gap distance between the electrodes. The Si and glass pieces were anodically bonded together to create a flow cell. The stability and reproducibility of single and dual electrode cells were characterized with cyclic voltammetry and amperometry during flow injection analysis (FIA). Single electrode detectors had detection limits of 50 nM with root mean square noise in the 3-10 pA range. The dual electrode cells showed enhanced sensitivity over single electrode cells through detection of analyte molecules multiple times as they were transported through the cell. Signal enhancements up to 60-fold were obtained with dual electrode cells during FIA at a flow rate of 50 nL/min. Simulations predict that signal-to-noise ratio enhancements > 100-fold may be possible with appropriate designs. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [41] Planar co-laminar flow microbial fuel cell with flow-through porous electrodes
    Choi, Taeseong
    Park, Noh Nyun
    Ahn, Yoomin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (09) : 14071 - 14079
  • [42] Flow-through cell for on-line amperometric determination of Ce(IV) during polymerization reactions
    Westbroek, P
    De Strycker, J
    Dubruel, P
    Temmerman, E
    Schacht, EH
    ANALYTICAL CHEMISTRY, 2002, 74 (04) : 915 - 920
  • [43] ANODIC DETECTION IN FLOW-THROUGH CELLS
    JOHNSON, DC
    POLTA, JA
    POLTA, TZ
    NEUBURGER, GG
    JOHNSON, J
    TANG, APC
    YEO, IH
    BAUR, J
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1081 - 1098
  • [44] Increasing the productivity of electrosynthesis with flow-through nanowire electrodes
    Wiley, Benjamin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [45] HYDRODYNAMIC EFFECTS ON EFFICIENCY OF POROUS FLOW-THROUGH ELECTRODES
    ATEYA, BG
    ARAFAT, EAS
    KAFAFI, SA
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1977, 7 (02) : 107 - 112
  • [46] FLOW-THROUGH ELECTRODE UNIT FOR LIQUID MEMBRANE ELECTRODES
    PAPASTATHOPOULOS, DS
    DIAMANDIS, EP
    HADJIIOANNOU, TP
    ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2100 - 2104
  • [47] ELECTROSORPTION OF ORGANICS ON FLOW-THROUGH POROUS-ELECTRODES
    ALKIRE, RC
    EISINGER, RS
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1981, 128 (03) : C72 - C72
  • [48] Faster bipolar capacitive deionization with flow-through electrodes
    Nordstrand, Johan
    Dutta, Joydeep
    ELECTROCHIMICA ACTA, 2023, 467
  • [49] Microfabricated flow-through device for DNA amplification - towards in situ gene analysis
    Fukuba, T
    Yamamoto, T
    Naganuma, T
    Fujii, T
    CHEMICAL ENGINEERING JOURNAL, 2004, 101 (1-3) : 151 - 156
  • [50] Amperometric biosensor-based flow-through microdetector for microdialysis applications
    Gáspár, S
    Wang, XW
    Suzuki, H
    Csöregi, E
    ANALYTICA CHIMICA ACTA, 2004, 525 (01) : 75 - 82