A microfabricated flow-through cell with parallel-opposed electrodes for recycling amperometric detection

被引:15
|
作者
Brooks, SA [1 ]
Kennedy, RT [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1997年 / 436卷 / 1-2期
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0022-0728(97)00224-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow-through recycling electrochemical detectors with dual Au electrodes were fabricated using micromachining techniques. Detector cells contained two microband electrodes that were 50 mu m wide by 3-5 mm long separated by a 5 or 10 mu m gap in a parallel-opposed configuration. One electrode was defined in the bottom of a channel which was etched into the surface of a Si wafer while the other electrode was defined on a glass substrate. The depth of the channel defined the gap distance between the electrodes. The Si and glass pieces were anodically bonded together to create a flow cell. The stability and reproducibility of single and dual electrode cells were characterized with cyclic voltammetry and amperometry during flow injection analysis (FIA). Single electrode detectors had detection limits of 50 nM with root mean square noise in the 3-10 pA range. The dual electrode cells showed enhanced sensitivity over single electrode cells through detection of analyte molecules multiple times as they were transported through the cell. Signal enhancements up to 60-fold were obtained with dual electrode cells during FIA at a flow rate of 50 nL/min. Simulations predict that signal-to-noise ratio enhancements > 100-fold may be possible with appropriate designs. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [31] On the effectiveness factor of flow-through porous electrodes
    Saleh, MM
    JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (35): : 13419 - 13426
  • [32] THEORY OF ELECTROANALYTICAL PROCESSES ON FLOW-THROUGH ELECTRODES
    OSTROVIDOV, EA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (11): : 1499 - 1502
  • [33] RETICULATED VITREOUS CARBON FLOW-THROUGH ELECTRODES
    STROHL, AN
    CURRAN, DJ
    ANALYTICAL CHEMISTRY, 1979, 51 (03) : 353 - 357
  • [34] A flow-through amperometric sensor for micro-analytical systems
    Pijanowska, DG
    Sprenkels, AJ
    Olthuis, W
    Bergveld, P
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3): : 98 - 102
  • [35] Flow-through amperometric immunosensor: Fast 'sandwich' scheme immunoassay
    Ghindilis, AL
    Krishnan, R
    Atanasov, P
    Wilkins, E
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (05): : 415 - 423
  • [36] Flow-through amperometric immunosensor: Fast 'sandwich' scheme immunoassay
    Ghindilis, A.L.
    Krishnan, R.
    Atanasov, P.
    Wilkins, E.
    Biosensors and Bioelectronics, 1997, 12 (05): : 415 - 423
  • [37] FLOW-THROUGH ANALYSIS OF GLUTATHIONE IN HUMAN ERYTHROCYTES WITH AN AMPEROMETRIC BIOSENSOR
    COMPAGNONE, D
    FEDERICI, G
    SCARCIGLIA, L
    PALLESCHI, G
    ANALYTICAL LETTERS, 1994, 27 (01) : 15 - 27
  • [38] OUTPUT PROPERTIES OF IRON-THIONINE PHOTOGALVANIC CELL WITH FLOW-THROUGH ELECTRODES
    SUDOH, M
    MURAKAMI, T
    SHIROTSUKA, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1983, 16 (01) : 61 - 66
  • [39] MASS AND CHARGE-TRANSFER IN POROUS FLOW-THROUGH ELECTRODES - CELL DESIGN
    OLIVE, H
    LACOSTE, G
    ONDE ELECTRIQUE, 1979, 59 (10): : 91 - 94
  • [40] CHARACTERIZATION OF MULTIPLE CARBON-FIBER MICROELECTRODES IN A FLOW-THROUGH CELL AND AMPEROMETRIC DETECTION WITH DILUTE ELECTROLYTE FOR LIQUID-CHROMATOGRAPHY
    JI, HM
    HE, J
    DONG, SJ
    WANG, EK
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 290 (1-2) : 93 - 103