Developing an EEG-based on-line closed-loop lapse detection and mitigation system

被引:22
|
作者
Wang, Yu-Te [1 ,2 ]
Huang, Kuan-Chih [3 ]
Wei, Chun-Shu [2 ,4 ]
Huang, Teng-Yi [3 ]
Ke, Li-Wei [5 ]
Lin, Chin-Teng [3 ]
Cheng, Chung-Kuan [1 ,6 ]
Jung, Tzyy-Ping [2 ,4 ,6 ]
机构
[1] Univ Calif San Diego, Jacobs Sch Engn, Dept Comp Sci & Engn, La Jolla, CA 92092 USA
[2] Univ Calif San Diego, Inst Neural Computat, Swartz Ctr Computat Neurosci, La Jolla, CA 92092 USA
[3] Natl Chiao Tung Univ, Dept Elect Engn, Hsinchu, Taiwan
[4] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, La Jolla, CA 92092 USA
[5] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu, Taiwan
[6] Univ Calif San Diego, Inst Engn Med, Ctr Adv Neurol Engn, La Jolla, CA 92092 USA
关键词
electroencephalogram (EEG); drowsiness; fatigue; driving; smartphone; cell-phone; brain computer interface (BCI); BRAIN-COMPUTER INTERFACES; BLIND SEPARATION; ALERTNESS; PERFORMANCE; SLEEPINESS; COMPONENT; WIRELESS; DYNAMICS; ELECTROENCEPHALOGRAPHY; PREDICTION;
D O I
10.3389/fnins.2014.00321
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In America, 60% of adults reported that they have driven a motor vehicle while feeling drowsy, and at least 15-20% of fatal car accidents are fatigue-related. This study translates previous laboratory-oriented neurophysiological research to design, develop, and test an On-line Closed-loop Lapse Detection and Mitigation (OCLDM) System featuring a mobile wireless dry-sensor EEG headgear and a cell-phone based real-time EEG processing platform. Eleven subjects participated in an event-related lane-keeping task, in which they were instructed to manipulate a randomly deviated, fixed-speed cruising car on a 4-lane highway. This was simulated in a 1st person view with an 8-screen and 8-projector immersive virtual-reality environment. When the subjects experienced lapses or failed to respond to events during the experiment, auditory warning was delivered to rectify the performance decrements. However, the arousing auditory signals were not always effective. The EEG spectra exhibited statistically significant differences between effective and ineffective arousing signals, suggesting that EEG spectra could be used as a countermeasure of the efficacy of arousing signals. In this on-line pilot study, the proposed OCLDM System was able to continuously detect EEG signatures of fatigue, deliver arousing warning to subjects suffering momentary cognitive lapses, and assess the efficacy of the warning in near real-time to rectify cognitive lapses. The on-line testing results of the OCLDM System validated the efficacy of the arousing signals in improving subjects' response times to the subsequent lane-departure events. This study may lead to a practical on-line lapse detection and mitigation system in real-world environments.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] On-line process identification from closed-loop tests under PI control
    Suganda, P
    Krishnaswamy, PR
    Rangaiah, GP
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A4): : 451 - 457
  • [32] Error detection system of photoelectric encoder based on optical continuous closed-loop
    Li, Kun
    Ding, Hongchang
    Cao, Guohua
    Hou, Han
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (07):
  • [33] Use of an EEG-bispectral closed-loop delivery system for administering propofol
    Sakai, T
    Matsuki, A
    White, PF
    Giesecke, AH
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (08) : 1007 - 1010
  • [34] Research and Implementation of Digital Detection System for Closed-Loop FOG
    Ge, Shengmin
    Han, Junliang
    Shen, Yi
    Bian, Zhiqiang
    Wang, Hui
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 6739 - 6744
  • [35] Long-term ICU sedation with an EEG controlled closed-loop system
    Albrecht, S
    Ihmsen, H
    Suchodolski, K
    Rommelsheim, K
    Schuttler, J
    ANESTHESIOLOGY, 1997, 87 (03) : A221 - A221
  • [36] Closed-Loop Neulmodulation System for Epilepsy Based on optogenetics
    Zhao, Yang
    Xu, Lin
    2018 IEEE 8TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (IEEE-CYBER), 2018, : 688 - 693
  • [37] A wearable EEG system for closed-loop neuromodulation of sleep-related oscillations
    Bressler, Scott
    Neely, Ryan
    Yost, Ryan M.
    Wang, David
    Read, Heather L.
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (05)
  • [38] Closed-Loop System Identification Based on Data Correlation
    Jammoussi, Hassene
    Franchek, Matthew
    Grigoriadis, Karolos
    Books, Martin
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [39] A Closed-loop System for Rapid Face Retrieval by Combining EEG and Computer Vision
    Wang, Yun
    Jiang, Lei
    Cai, Bangyu
    Wang, Yiwen
    Zhang, Shaomin
    Zheng, Xiaoxiang
    2015 7TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2015, : 130 - 133
  • [40] Closed-loop Control in EMR Based on a BI System
    Tao, Min
    Wang, Yu
    Tian, Yu
    Li, Jing-song
    2015 IEEE International Conference on Signal Processing, Communications and Computing (ICSPCC), 2015, : 26 - 29