Developing an EEG-based on-line closed-loop lapse detection and mitigation system

被引:22
|
作者
Wang, Yu-Te [1 ,2 ]
Huang, Kuan-Chih [3 ]
Wei, Chun-Shu [2 ,4 ]
Huang, Teng-Yi [3 ]
Ke, Li-Wei [5 ]
Lin, Chin-Teng [3 ]
Cheng, Chung-Kuan [1 ,6 ]
Jung, Tzyy-Ping [2 ,4 ,6 ]
机构
[1] Univ Calif San Diego, Jacobs Sch Engn, Dept Comp Sci & Engn, La Jolla, CA 92092 USA
[2] Univ Calif San Diego, Inst Neural Computat, Swartz Ctr Computat Neurosci, La Jolla, CA 92092 USA
[3] Natl Chiao Tung Univ, Dept Elect Engn, Hsinchu, Taiwan
[4] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, La Jolla, CA 92092 USA
[5] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu, Taiwan
[6] Univ Calif San Diego, Inst Engn Med, Ctr Adv Neurol Engn, La Jolla, CA 92092 USA
关键词
electroencephalogram (EEG); drowsiness; fatigue; driving; smartphone; cell-phone; brain computer interface (BCI); BRAIN-COMPUTER INTERFACES; BLIND SEPARATION; ALERTNESS; PERFORMANCE; SLEEPINESS; COMPONENT; WIRELESS; DYNAMICS; ELECTROENCEPHALOGRAPHY; PREDICTION;
D O I
10.3389/fnins.2014.00321
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In America, 60% of adults reported that they have driven a motor vehicle while feeling drowsy, and at least 15-20% of fatal car accidents are fatigue-related. This study translates previous laboratory-oriented neurophysiological research to design, develop, and test an On-line Closed-loop Lapse Detection and Mitigation (OCLDM) System featuring a mobile wireless dry-sensor EEG headgear and a cell-phone based real-time EEG processing platform. Eleven subjects participated in an event-related lane-keeping task, in which they were instructed to manipulate a randomly deviated, fixed-speed cruising car on a 4-lane highway. This was simulated in a 1st person view with an 8-screen and 8-projector immersive virtual-reality environment. When the subjects experienced lapses or failed to respond to events during the experiment, auditory warning was delivered to rectify the performance decrements. However, the arousing auditory signals were not always effective. The EEG spectra exhibited statistically significant differences between effective and ineffective arousing signals, suggesting that EEG spectra could be used as a countermeasure of the efficacy of arousing signals. In this on-line pilot study, the proposed OCLDM System was able to continuously detect EEG signatures of fatigue, deliver arousing warning to subjects suffering momentary cognitive lapses, and assess the efficacy of the warning in near real-time to rectify cognitive lapses. The on-line testing results of the OCLDM System validated the efficacy of the arousing signals in improving subjects' response times to the subsequent lane-departure events. This study may lead to a practical on-line lapse detection and mitigation system in real-world environments.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] An EEG-Based Fatigue Detection and Mitigation System
    Huang, Kuan-Chih
    Huang, Teng-Yi
    Chuang, Chun-Hsiang
    King, Jung-Tai
    Wang, Yu-Kai
    Lin, Chin-Teng
    Jung, Tzyy-Ping
    INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2016, 26 (04)
  • [2] Performance of an on-line closed-loop color control system
    Pope, B
    Sweeney, J
    DISSEMINATING GRAPHIC ARTS RESEARCH INTERNATIONALLY SINCE 1948, 2000 TAGA PROCEEDINGS, 2000, : 417 - 431
  • [3] EEG-Based Closed-Loop Neurofeedback for Attention Monitoring and Training in Young Adults
    Wang, Bingbing
    Xu, Zeju
    Luo, Tong
    Pan, Jiahui
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021 : 5535810
  • [4] EEG-Based Closed-Loop Neurofeedback for Attention Monitoring and Training in Young Adults
    Wang, Bingbing
    Xu, Zeju
    Luo, Tong
    Pan, Jiahui
    Pan, Jiahui (panjh82@qq.com), 1600, Hindawi Limited (2021):
  • [5] On-line closed-loop model validation and detection of abrupt parameter changes
    Huang, BA
    JOURNAL OF PROCESS CONTROL, 2001, 11 (06) : 699 - 715
  • [6] On-line, closed-loop identification of multivariable systems
    Melo, Diogenes L.
    Friedly, John C.
    Industrial and Engineering Chemistry Research, 1992, 31 (01): : 274 - 281
  • [7] Implementation of a closed-loop real-time EEG-based drowsiness detection system: Effects of feedback alarms on performance in a driving simulator
    Berka, C
    Levendowski, DJ
    Westbrook, P
    Davis, G
    Lumicao, MN
    Olmstead, RE
    Popovic, M
    Zivkovic, VT
    Ramsey, CK
    FOUNDATIONS OF AUGMENTED COGNITION, VOL 11, 2005, : 651 - 660
  • [8] EEG-based lapse detection with high temporal resolution
    Davidson, Paul R.
    Jones, Richard D.
    Peiris, Malik T. R.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (05) : 832 - 839
  • [9] AttentivU: An EEG-Based Closed-Loop Biofeedback System for Real-Time Monitoring and Improvement of Engagement for Personalized Learning
    Kosmyna, Nataliya
    Maes, Pattie
    SENSORS, 2019, 19 (23)
  • [10] Intracorporeal Cortical Telemetry as a Step to Automatic Closed-Loop EEG-Based CI Fitting: A Proof of Concept
    Beynon, Andy J.
    Luijten, Bart M.
    Mylanus, Emmanuel A. M.
    AUDIOLOGY RESEARCH, 2021, 11 (04) : 691 - 705