Ion-selective optical sensor for continuous on-line monitoring of dialysate sodium during dialysis

被引:1
|
作者
Sharma, Manoj K. [1 ]
Frijns, Arjan J. H. [1 ]
Mandamparambil, Rajesh [2 ]
Kooman, Jeroen P. [3 ]
Smeulders, David M. J. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Mech Engn, Eindhoven, Netherlands
[2] TNO, Eindhoven, Netherlands
[3] Maastricht Univ Med Ctr MUMC, Maastricht, Netherlands
关键词
Optical sensor; Micro-optofluidics; On-line electrolyte monitoring; Dialysis; Photoinduced electron transfer; FLUORESCENT; SYSTEMS;
D O I
10.1117/12.2251923
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Patients with end stage renal disease are dependent on dialysis. In most outpatient centers, the dialysate is prepared with a fixed electrolyte concentration without taking into account the inter-individual differences of essential electrolytes (sodium, potassium and calcium). This one-size fits all approach can lead to acute and chronic cardiovascular complications in dialysis patients. On-line monitoring of these essential electrolytes is an important physiological step towards patient specific dialysate leading to individualized treatment. Currently, changes in electrolyte concentrations are indirectly measured by conductivity measurements, which are not ion-specific. In this paper, we present a novel optical sensor for on-line monitoring of sodium concentrations in dialysate. This sensor is ion-specific and can detect up to a single ion. The working principle is based on the selective fluorescence quenching of photo-induced electron transfer (PET) molecules. The PET molecules when complexed with sodium ions start fluorescing upon laser excitation. The emission intensity is directly correlated to the sodium concentration. To prove the working principle, a micro-optofluidic device has been fabricated in polydimethylsiloxane (PDMS) with integrated optical fibers for fluorescence light collection. The PET molecules are covalently grafted in the PDMS microchannel for continuous monitoring of the sodium dialysate concentrations. The experimental setup consists of a laser module (lambda=450nm) operating at 4.5mW, a syringe pump to precisely control the sample flow and a spectrometer for fluorescence collection. The performance of the sensor has been evaluated for sodium ions ranging from 0-50mM. A clear signal and good response time was observed.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] GRADIENT TITRATION - NOVEL APPROACH TO CONTINUOUS MONITORING USING ION-SELECTIVE ELECTRODES
    FLEET, B
    HO, AYW
    ANALYTICAL CHEMISTRY, 1974, 46 (01) : 9 - 11
  • [32] Paper-based ion-selective optodes for continuous sensing: Reversible potassium ion monitoring
    Kassal, Petar
    Sigurnjak, Marija
    Steinberg, Ivana Murkovic
    TALANTA, 2019, 193 : 51 - 55
  • [33] Bias in the Determination of Dialysate Sodium Concentration Set According to Conductivity Relative to Indirect Ion-Selective Measurement Techniques
    Sheikh, Rayees
    Hiremath, Swapnil
    Clark, Edward G.
    Akbari, Ayub
    McCudden, Christopher
    Brown, Pierre Antoine
    KIDNEY INTERNATIONAL REPORTS, 2020, 5 (06): : 931 - 934
  • [34] On-line monitoring of the intravascular volume during haemodialysis by continuous refractometry
    Kuhlmann, U
    Buuren, FV
    Aziz, O
    Lange, H
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (04): : 205 - 209
  • [35] A Differential Transformer for Noninvasive Continuous Sodium Monitoring During Dialysis Treatment
    Berger, Marc
    Sellering, Flora
    Roehrich, Hannes
    Mansour, Hussam
    Perl, Thorsten
    Zimmermann, Stefan
    2019 IEEE SENSORS, 2019,
  • [36] A Highly Sensitive and Selective Optical Sensor for the On-Line Detection of Cesium in Water
    Depauw, Alexis
    Jonusauskaite, Laura
    Ghasemi, Rasta
    Lefevre, Jean-Pierre
    Mongin, C.
    Genot, Valerie
    Delaire, Jacques
    Leray, Isabelle
    SENSORS, 2023, 23 (18)
  • [37] A novel, optical, on-line bacteria sensor for monitoring drinking water quality
    Bo Højris
    Sarah Christine Boesgaard Christensen
    Hans-Jørgen Albrechtsen
    Christian Smith
    Mathis Dahlqvist
    Scientific Reports, 6
  • [38] Optical fiber sensor for an on-line monitoring of epoxy resin/amine reaction
    Fouchal, F
    Knight, JAG
    Garrington, N
    Cope, B
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 961 - 968
  • [39] A novel, optical, on-line bacteria sensor for monitoring drinking water quality
    Hojris, Bo
    Christensen, Sarah Christine Boesgaard
    Albrechtsen, Hans-Jorgen
    Smith, Christian
    Dahlqvist, Mathis
    SCIENTIFIC REPORTS, 2016, 6
  • [40] An Integrated Glucose Sensor with an All-Solid-State Sodium Ion-Selective Electrode for a Minimally Invasive Glucose Monitoring System
    Kojima, Junko
    Hosoya, Samiko
    Suminaka, Chihiro
    Hori, Nobuyasu
    Sato, Toshiyuki
    MICROMACHINES, 2015, 6 (07): : 831 - 841