Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients

被引:2
|
作者
Camerucci, Emanuele [1 ]
Campeau, Norbert G. [1 ]
Trzasko, Joshua D. [1 ]
Gray, Erin M. [1 ]
Bernstein, Matt A. [1 ]
Cogswell, Petrice M. [1 ]
Shu, Yunhong [1 ]
Foo, Thomas K. [2 ]
Huston, John, III [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] GE Res, Niskayuna, NY USA
关键词
MRI; brain; 3T; ACCURACY;
D O I
10.1002/jmri.27812
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background A low-cryogen, compact 3T (C3T) MRI scanner with high-performance gradients capable of simultaneously achieving 80 mT/m gradient amplitude and 700 T/m/second slew rate has been in use to study research patients since March 2016 but has not been implemented in the clinical practice. Purpose To compare head MRI examinations obtained with the C3T system and a conventional whole-body 3T (WB3T) scanner in seven parameters across five commonly used brain imaging sequences. Study Type Prospective. Subjects Thirty patients with a clinically indicated head MRI. Sequence 3T; T1 FLAIR, T1 MP-RAGE, 3D T2 FLAIR, T2 FSE, and DWI. Assessment All patients tolerated the scans well. Three board-certified neuroradiologists scored the comparative quality of C3T and WB3T images in blinded fashion using a five-point Likert scale in terms of: signal-to-noise ratio, lesion conspicuity, motion artifact, gray/white matter contrast, cerebellar folia, susceptibility artifact, and overall quality. Statistical Test Left-sided, right-sided, and two-sided Wilcoxon signed rank test; Fisher's method. A P value The C3T system performed better than the WB3T in virtually all comparisons, except for motion artifacts for the T1 FLAIR and T1 MP-RAGE sequences, where the WB3T system was deemed better. When combining all sequences together, the C3T system outperformed the WB3T system in all image quality parameters evaluated, except for motion artifact (P = 0.13). Data Conclusion The C3T scanner provided better overall image quality for all sequences, and performed better in all individual categories, except for motion artifact on the T1 FLAIR and T1 MP-RAGE. Level of Evidence 2 Technical Efficacy Stage 1
引用
收藏
页码:166 / 175
页数:10
相关论文
共 50 条
  • [21] An MR technique for simultaneous quantitative imaging of water content, conductivity and susceptibility, with application to brain tumours using a 3T hybrid MR-PET scanner
    Yupeng Liao
    Ana-Maria Oros-Peusquens
    Johannes Lindemeyer
    Nazim Lechea
    Carolin Weiß -Lucas
    Karl-Josef Langen
    N. Jon Shah
    Scientific Reports, 9
  • [22] Normal Pituitary Stalk: High-Resolution MR Imaging at 3T
    Satogami, N.
    Miki, Y.
    Koyama, T.
    Kataoka, M.
    Togashi, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (02) : 355 - 359
  • [23] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [24] Design and Simulation of a Helmholtz Coil for Magnetic Resonance Imaging and Spectroscopy Experiments with a 3T MR Clinical Scanner
    Giovannetti, Giulio
    Frijia, Francesca
    Flori, Alessandra
    Montanaro, Domenico
    APPLIED MAGNETIC RESONANCE, 2019, 50 (09) : 1083 - 1097
  • [25] Design and Simulation of a Helmholtz Coil for Magnetic Resonance Imaging and Spectroscopy Experiments with a 3T MR Clinical Scanner
    Giulio Giovannetti
    Francesca Frijia
    Alessandra Flori
    Domenico Montanaro
    Applied Magnetic Resonance, 2019, 50 : 1083 - 1097
  • [26] Automatic Fetal Brain Localization in 3T MR Images using Histograms of Oriented 3D Gradients
    Serag, Ahmed
    Boardman, James P.
    Reynolds, Rebecca M.
    Denison, Fiona C.
    Macnaught, Gillian
    Semple, Scott I.
    2016 24TH SIGNAL PROCESSING AND COMMUNICATION APPLICATION CONFERENCE (SIU), 2016, : 2273 - 2276
  • [27] MR Imaging of the nerve root of the lumbar vertebra with a 3T high field machine
    Mizuuchi, N.
    Maruyama, K.
    Moroi, T.
    Imura, C.
    Isobe, I.
    Usagawa, T.
    Iriguchi, N.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 786 - 789
  • [28] Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T
    Eliezer, Michael
    Vaussy, Alexis
    Toupin, Solenn
    Barbe, Remy
    Kannengiesser, Stephan
    Stemmer, Alto
    Houdart, Emmanuel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 13 - 20
  • [29] Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
    Li, Ming-li
    Xu, Wei-hai
    Song, Lan
    Feng, Feng
    You, Hui
    Ni, Jun
    Gao, Shan
    Cui, Li-ying
    Jin, Zheng-yu
    ATHEROSCLEROSIS, 2009, 204 (02) : 447 - 452
  • [30] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Gokce Hale Hatay
    Muhammed Yildirim
    Esin Ozturk-Isik
    Medical & Biological Engineering & Computing, 2017, 55 : 1303 - 1315