Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer Vascular Plug-II

被引:18
|
作者
Hua, Nancy [1 ]
Aquino, Paolo [2 ]
Owada, Carl Y. [2 ]
机构
[1] UCSF Fresno Pediat Residency Program, Fresno, CA USA
[2] Valley Childrens Hosp, Dept Cardiol & Cardiothorac Surg, FE-14,9300 Valley Childrens Pl, Madera, CA 93636 USA
关键词
Paediatric interventions; transcatheter device closure; congenital heart disease; MEMBRANOUS VSD OCCLUDER; FOLLOW-UP; EXPERIENCE; DEVICE; BLOCK; RISK;
D O I
10.1017/S1047951115002206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the safety and efficacy of the Amplatzer Vascular Plug-II used for the closure of perimembranous ventricular septal defects. Background: There are no FDA-approved transcatheter devices for the closure of perimembranous ventricular septal defects. Several studies have reported on the use of various devices either off-label or under clinical trial protocols. However these reports have described significant adverse events including residual shunts, complete heart block, arrhythmia, and new valve regurgitations. Thus far, no study on the Amplatzer Vascular Plug-II has been reported. Methods: We conducted a 4-year retrospective chart review from August, 2010 to August, 2014, of patients with perimembranous ventricular septal defects associated with ventricular septal aneurysm who underwent transcatheter closure using the Amplatzer Vascular Plug-II. Results: A total of 16 patients underwent Amplatzer Vascular Plug-II transcatheter closure of their perimembranous ventricular septal defects. The median age was 2.56 years (range: 0.5-27.3). Their median weight was 13.0 kg (range: 6.9-71.6). The left ventricular median defect size was 9.3 mm (range: 5.9-14.4). The right ventricular median defect size was 3.6 mm (range: 2.3-5.8). All the patients underwent successful device implantation with 83% of the patients having complete echocardiographic closure at the 1-year follow-up; however, one procedure was complicated by early device embolisation. The device was successfully retrieved and replaced with a larger device. There were no device-related outflow tract obstructions, rhythm abnormalities, or haemolysis. Conclusion: Application of the Amplatzer Vascular Plug-II for closure of perimembranous ventricular septal defects appears to be a safe and effective treatment option. Prospective clinical trials and longer follow-up periods are warranted.
引用
收藏
页码:1194 / 1201
页数:8
相关论文
共 50 条
  • [41] TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECT
    Lorber, A.
    Dotan, M.
    Or, Y.
    CARDIOLOGY, 2015, 131 : 43 - 43
  • [42] Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders - a single centre experience
    Szkutnik, Malgorzata
    Kusa, Jacek
    Bialkowski, Jacek
    KARDIOLOGIA POLSKA, 2008, 66 (09) : 941 - 949
  • [43] Catheter closure of perimembranous/membranous ventricular septal defects using the amplatzer occluder device
    Thanopoulos, BD
    PEDIATRIC CARDIOLOGY, 2005, 26 (04) : 311 - 314
  • [44] Comparison of results and complications of surgical and Amplatzer device closure of perimembranous ventricular septal defects
    Cheng Xunmin
    Jiang Shisen
    Gong Jianbin
    Wang Haidong
    Wang Lijun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 120 (01) : 28 - 31
  • [45] Transcatheter Closure of Perimembranous Ventricular Septal Defects with Left Ventricular to Right Atrial Shunt
    Gunter Kerst
    Axel Moysich
    Siew Yen Ho
    Christian Apitz
    Heiner Latus
    Dietmar Schranz
    Pediatric Cardiology, 2015, 36 : 1386 - 1392
  • [46] Transcatheter retrograde closure of perimembranous ventricular septal defects in children with the Amplatzer Duct Occluder II Device (vol 60, pg 2421, 2012)
    Koneti, Nageswara Rao
    Sreeram, Narayanswami
    Penumatsa, Raghava Raju
    Arramraj, Srinivas K.
    Karunakar, Vadlamudi
    Trieschmann, Uwe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (05) : 598 - 598
  • [47] Outcome of transcatheter closure of muscular ventricular septal defects with the Amplatzer ventricular septal defect occluder
    Thanopoulos, BD
    Rigby, ML
    HEART, 2005, 91 (04) : 513 - 516
  • [48] Percutaneous closure of perimembranous ventricular septal defects with the amplatzer device: Technical and morphological considerations
    Pedra, CAC
    Pedra, SRF
    Esteves, CA
    Pontes, SC
    Braga, SLN
    Arrieta, SR
    Santana, MVT
    Fontes, VF
    Masura, J
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (03) : 403 - 410
  • [49] Transcatheter Closure of Perimembranous Ventricular Septal Defects with Left Ventricular to Right Atrial Shunt
    Kerst, Gunter
    Moysich, Axel
    Ho, Siew Yen
    Apitz, Christian
    Latus, Heiner
    Schranz, Dietmar
    PEDIATRIC CARDIOLOGY, 2015, 36 (07) : 1386 - 1392
  • [50] Transcatheter Closure of Left Ventricular Apical Pseudoaneurysm with an Amplatzer Vascular Plug
    Negri, Francesco
    Cernetti, Carlo
    Favero, Luca
    Minniti, Giuseppe
    De Leo, Alessandro
    De Simone, Giovanna
    Sinagra, Gianfranco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (11) : 1033 - 1035