Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer Vascular Plug-II

被引:18
|
作者
Hua, Nancy [1 ]
Aquino, Paolo [2 ]
Owada, Carl Y. [2 ]
机构
[1] UCSF Fresno Pediat Residency Program, Fresno, CA USA
[2] Valley Childrens Hosp, Dept Cardiol & Cardiothorac Surg, FE-14,9300 Valley Childrens Pl, Madera, CA 93636 USA
关键词
Paediatric interventions; transcatheter device closure; congenital heart disease; MEMBRANOUS VSD OCCLUDER; FOLLOW-UP; EXPERIENCE; DEVICE; BLOCK; RISK;
D O I
10.1017/S1047951115002206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the safety and efficacy of the Amplatzer Vascular Plug-II used for the closure of perimembranous ventricular septal defects. Background: There are no FDA-approved transcatheter devices for the closure of perimembranous ventricular septal defects. Several studies have reported on the use of various devices either off-label or under clinical trial protocols. However these reports have described significant adverse events including residual shunts, complete heart block, arrhythmia, and new valve regurgitations. Thus far, no study on the Amplatzer Vascular Plug-II has been reported. Methods: We conducted a 4-year retrospective chart review from August, 2010 to August, 2014, of patients with perimembranous ventricular septal defects associated with ventricular septal aneurysm who underwent transcatheter closure using the Amplatzer Vascular Plug-II. Results: A total of 16 patients underwent Amplatzer Vascular Plug-II transcatheter closure of their perimembranous ventricular septal defects. The median age was 2.56 years (range: 0.5-27.3). Their median weight was 13.0 kg (range: 6.9-71.6). The left ventricular median defect size was 9.3 mm (range: 5.9-14.4). The right ventricular median defect size was 3.6 mm (range: 2.3-5.8). All the patients underwent successful device implantation with 83% of the patients having complete echocardiographic closure at the 1-year follow-up; however, one procedure was complicated by early device embolisation. The device was successfully retrieved and replaced with a larger device. There were no device-related outflow tract obstructions, rhythm abnormalities, or haemolysis. Conclusion: Application of the Amplatzer Vascular Plug-II for closure of perimembranous ventricular septal defects appears to be a safe and effective treatment option. Prospective clinical trials and longer follow-up periods are warranted.
引用
收藏
页码:1194 / 1201
页数:8
相关论文
共 50 条
  • [11] Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device
    Pedra, CA
    Pedra, SF
    Esteves, CA
    Pontes, SC
    Braga, SL
    Arrieta, R
    Santana, MV
    Masura, J
    Fontes, VF
    CIRCULATION, 2003, 108 (17) : 496 - 496
  • [12] Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Amplatzer Duct Occluder II
    Sun, Hongxiao
    Luo, Gang
    Du, Zhanhui
    Ji, Zhixian
    Pan, Silin
    CONGENITAL HEART DISEASE, 2021, 16 (02) : 151 - 157
  • [13] Transcatheter Closure of Multiple Perimembranous Ventricular Septal Defects With Septal Aneurysm Using Two Overlapping Amplatzer Duct Occluders II
    Devendran, Vimalarani
    Koneti, Nageswara Rao
    Jesudian, Vimala
    PEDIATRIC CARDIOLOGY, 2013, 34 (08) : 1963 - 1965
  • [14] Transcatheter Closure of Multiple Perimembranous Ventricular Septal Defects With Septal Aneurysm Using Two Overlapping Amplatzer Duct Occluders II
    Vimalarani Devendran
    Nageswara Rao Koneti
    Vimala Jesudian
    Pediatric Cardiology, 2013, 34 : 1963 - 1965
  • [15] Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children
    Thanopoulos, BD
    Tsaousis, GS
    Karanasios, E
    Eleftherakis, NG
    Paphitis, C
    HEART, 2003, 89 (08) : 918 - 922
  • [16] Transcatheter closure of perimembranous ventricular septal defects with the amplatzer asymmetric ventricular septal defect occluder: Preliminary experience in children
    Thanopoulos, BD
    Tsaousis, GS
    Karanasios, E
    Stefanadis, C
    Sophia, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 473A - 473A
  • [17] Ten Year Experience with Transcatheter Closure of Perimembranous Ventricular Septal Defects Using the Amplatzer Asymmetric Perimembranous Ventricular Septal Defect Occluder in Children
    Thanopoulos, Vasileios
    Giannopoulos, Andreas
    Tsaousis, George
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B225 - B225
  • [18] Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: Immediate results
    Holzer, RJ
    Hijazi, ZM
    Wilkinson, J
    Sievert, H
    DeGiovanni, J
    Hakim, F
    Walsh, K
    Hroob, A
    Bonhoeffer, P
    CIRCULATION, 2003, 108 (17) : 705 - 705
  • [19] Outcomes of transcatheter closure of perimembranous or outlet type ventricular septal defects using Amplatzer duct occluders
    Wang, J. -K.
    Lin, M. -T.
    Chen, C. -A.
    Chiu, S. -N.
    Lu, J. -W.
    Wu, M. -H.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1370 - 1370
  • [20] Transcatheter Closure of Postoperative Residual Perimembranous Ventricular Septal Defects
    Gu, Ming-Biao
    Bai, Yuan
    Zhao, Xian-Xian
    Zheng, Xing
    Li, Wei-Ping
    Qin, Yong-Wen
    ANNALS OF THORACIC SURGERY, 2009, 88 (05): : 1551 - 1555