Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer Vascular Plug-II

被引:18
|
作者
Hua, Nancy [1 ]
Aquino, Paolo [2 ]
Owada, Carl Y. [2 ]
机构
[1] UCSF Fresno Pediat Residency Program, Fresno, CA USA
[2] Valley Childrens Hosp, Dept Cardiol & Cardiothorac Surg, FE-14,9300 Valley Childrens Pl, Madera, CA 93636 USA
关键词
Paediatric interventions; transcatheter device closure; congenital heart disease; MEMBRANOUS VSD OCCLUDER; FOLLOW-UP; EXPERIENCE; DEVICE; BLOCK; RISK;
D O I
10.1017/S1047951115002206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the safety and efficacy of the Amplatzer Vascular Plug-II used for the closure of perimembranous ventricular septal defects. Background: There are no FDA-approved transcatheter devices for the closure of perimembranous ventricular septal defects. Several studies have reported on the use of various devices either off-label or under clinical trial protocols. However these reports have described significant adverse events including residual shunts, complete heart block, arrhythmia, and new valve regurgitations. Thus far, no study on the Amplatzer Vascular Plug-II has been reported. Methods: We conducted a 4-year retrospective chart review from August, 2010 to August, 2014, of patients with perimembranous ventricular septal defects associated with ventricular septal aneurysm who underwent transcatheter closure using the Amplatzer Vascular Plug-II. Results: A total of 16 patients underwent Amplatzer Vascular Plug-II transcatheter closure of their perimembranous ventricular septal defects. The median age was 2.56 years (range: 0.5-27.3). Their median weight was 13.0 kg (range: 6.9-71.6). The left ventricular median defect size was 9.3 mm (range: 5.9-14.4). The right ventricular median defect size was 3.6 mm (range: 2.3-5.8). All the patients underwent successful device implantation with 83% of the patients having complete echocardiographic closure at the 1-year follow-up; however, one procedure was complicated by early device embolisation. The device was successfully retrieved and replaced with a larger device. There were no device-related outflow tract obstructions, rhythm abnormalities, or haemolysis. Conclusion: Application of the Amplatzer Vascular Plug-II for closure of perimembranous ventricular septal defects appears to be a safe and effective treatment option. Prospective clinical trials and longer follow-up periods are warranted.
引用
收藏
页码:1194 / 1201
页数:8
相关论文
共 50 条
  • [1] Transcatheter closure of large perimembranous ventricular septal defects with inlet to outlet extension with the Amplatzer Vascular Plug-II
    Piccinelli, Enrico
    Bautista-Rodriguez, Carles
    Fraisse, Alain
    CARDIOLOGY IN THE YOUNG, 2023, 33 (06) : 1018 - 1022
  • [2] Transcatheter Closure of Perimembranous Ventricular Septal Defects with the Amplatzer Vascular Plug II: Acute and Mid-term Results
    Evans, Teresa
    Moore, Phillip
    Meadows, Jeffery
    Teitel, David
    Amin, Elena
    PEDIATRIC CARDIOLOGY, 2022, 43 (08) : 2023 - 2023
  • [3] Closure of perimembranous ventricular septal defects using the Amplatzer vascular plug II: experience of a Mexican centre
    Mijangos-Vazquez, Roberto
    Hernandez-Reyes, Rogelio
    CARDIOLOGY IN THE YOUNG, 2025,
  • [4] Transcatheter Closure of Perimembranous Ventricular Septal Defects With Amplatzer Duct Occluders
    Lin, Ming-Tai
    Chen, Chun-An
    Hsu, Jui-Yu
    Lin, Hsin-Chia
    Chiu, Shuenn-Nan
    Lin, Shu-Man
    Chang, Ya-Mei
    Lu, Chun-Wei
    Wu, Mei-Hwan
    Wang, Jou-Kou
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (21) : 2227 - 2228
  • [5] THE CLINICAL EVALUATION OF TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECTS WITH THE AMPLATZER DUCT OCCLUDER II
    Yu Zhiqing
    Fu Lijun
    Li Yun
    Zhang Yuqi
    Li Fen
    Huang Meirong
    Guo Ying
    HEART, 2011, 97
  • [6] Transcatheter closure of perimembranous ventricular septal defects in infants and children using the amplatzer perimembranous ventricular septal defect occluder
    Thanopoulos, Basil Vasilios D.
    Rigby, Michael L.
    Karanasios, Evangelos
    Stefanadis, Christodoulos
    Blom, Nico
    Ottenkamp, Jaap
    Zarayelyan, Armine
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (07): : 984 - 989
  • [7] Transcatheter closure of an unligated vertical vein with an Amplatzer Vascular Plug-II device
    Lombardi, M.
    Tagliente, R.
    Pirolo, T.
    Massari, E.
    Sisto, M.
    Vairo, U.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 : E221 - E223
  • [8] Transcatheter Retrograde Closure of Perimembranous Ventricular Septal Defects in Children With the Amplatzer Duct Occluder II Device
    Koneti, Nageswara Rao
    Sreeram, Narayanswami
    Penumatsa, Raghava Raju
    Arramraj, Srinivas K.
    Karunakar, Vadlamudi
    Trieschmann, Uwe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (23) : 2421 - 2422
  • [9] Transcatheter Closure of Perimembranous and Intracristal Ventricular Septal Defects Using Amplatzer Duct Occluder II in Children
    Liu, Shenrong
    Zhang, Wenqian
    Li, Junjie
    Wang, Shushui
    Qian, Mingyang
    Shi, Jijun
    Xie, Yumei
    Zhang, Zhiwei
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2021, 2021
  • [10] Preliminary experience with transcatheter closure of wind-sock-like perimembranous ventricular septal defects using Amplatzer Vascular Plug IV devices
    Leong, Ming Chern
    Hoo, Xin Yi
    Alwi, Mazeni
    CARDIOLOGY IN THE YOUNG, 2024, 34 (01) : 228 - 231