Quality of Micro-CT Images Acquired from Simultaneous Micro-CT and Benchtop X-Ray Fluorescence Computed Tomography (XFCT): A Preliminary Monte Carlo Study

被引:0
|
作者
Manohar, Nivedh [1 ]
Cho, Sang Hyun [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
NANOPARTICLE-LOADED OBJECTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Integration of micro-CT with benchtop x-ray fluorescence computed tomography (XFCT) for multimodal imaging poses challenges due to significantly different operating conditions between the two modalities. This Monte Carlo (MC) study investigated the quality of micro-CT images obtainable with incident x-ray spectra that were optimized for benchtop XFCT and, consequently, considerably harder than those typically used for micro-CT. An MC model was created in MCNP5, featuring a cylindrical polymethyl methacrylate phantom (3-cm-diameter) with cylindrical inserts (6-mm-diameter) containing water loaded with gold nanoparticles (2, 1, and 0.5% by weight). The phantom was irradiated by a polychromatic cone-beam x-ray source operated at various tube potentials and filtration. Transmitted photons were scored while the phantom was rotated to generate projections for axial image reconstruction. Reconstructed micro-CT images were comparable to experimentally-obtained images under similar imaging conditions. For a given dose, the contrast and image quality generally decreased with increasing hardness of the incident x-ray spectrum. The results suggest that it would be difficult to achieve the contrast typical of micro-CT images with incident x-ray spectra optimized for benchtop cone-beam XFCT. Further optimization efforts and/or developing alternative imaging schemes (e.g., dual-energy scan) will be necessary to improve micro-CT image quality during simultaneous micro-CT/XF'CT scanning.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] X-ray micro-CT study of Cabeco de Vide serpentinites and carbonate rock samples: a preliminary approach
    Mauricio, A.
    Pereira, M. F.
    Rocha, C.
    Figueiredo, C.
    Marques, J. M.
    15TH WATER-ROCK INTERACTION INTERNATIONAL SYMPOSIUM, WRI-15, 2017, 17 : 952 - 955
  • [42] Extracting Myofibre Orientation from Micro-CT Images: An Optimisation Study
    Ni, Haibo
    Castro, Simon J.
    Stephenson, Robert S.
    Jarvis, Jonathan C.
    Lowe, Tristan
    Hart, George
    Boyett, Mark R.
    Zhang, Henggui
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 823 - 826
  • [43] Micro-CT in a dual-modality fluorescence/computed tomography system for small animal Imaging
    Zhang, Hui
    Li, Hao
    Hu, Gang
    Hu, Guangshu
    Bai, Jing
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3735 - 3737
  • [44] Data-Constrained Microstructure Characterization with Multispectrum X-Ray Micro-CT
    Mayo, Sheridan C.
    Tulloh, Andrew M.
    Trinchi, Adrian
    Yang, Sam Y. S.
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (03) : 524 - 530
  • [45] A reconstruction of the lophophore of Devonian rhynchonellids (Brachiopoda) by using X-Ray micro-CT
    A. V. Pakhnevich
    Paleontological Journal, 2017, 51 : 143 - 154
  • [46] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [47] X-ray micro-CT applied to natural building materials and art objects
    De Witte, Y.
    Cnudde, V.
    Pieters, K.
    Masschaele, B.
    Dierick, M.
    Vlassenbroeck, J.
    Van Hoorebeke, L.
    Jacobs, P.
    X-RAY SPECTROMETRY, 2008, 37 (04) : 383 - 387
  • [48] X-ray micro-CT measurement of large parts at very low temperature
    Koutecky, T.
    Zikmund, T.
    Glittova, D.
    Palousek, D.
    Zivcak, J.
    Kaiser, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [49] X-ray Micro-CT based characterization of rock cuttings with deep learning
    Olsen, Nils
    Chen, Yifeng
    Turberg, Pascal
    Moreau, Alexandre
    Alahi, Alexandre
    APPLIED COMPUTING AND GEOSCIENCES, 2025, 25
  • [50] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75