A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project

被引:43
|
作者
Tran-Gia, Johannes [1 ]
Denis-Bacelar, Ana M. [2 ]
Ferreira, Kelley M. [2 ]
Robinson, Andrew P. [2 ,3 ,4 ]
Calvert, Nicholas [3 ]
Fenwick, Andrew J. [2 ,5 ]
Finocchiaro, Domenico [6 ,7 ]
Fioroni, Federica [6 ]
Grassi, Elisa [6 ]
Heetun, Warda [2 ]
Jewitt, Stephanie J. [8 ]
Kotzassarlidou, Maria [9 ]
Ljungberg, Michael [10 ]
McGowan, Daniel R. [8 ,11 ]
Scott, Nathaniel [8 ,13 ]
Scuffham, James [2 ,12 ]
Gleisner, Katarina Sjogreen [10 ]
Tipping, Jill [3 ]
Wevrett, Jill [2 ,12 ,13 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Natl Phys Lab, Teddington, Middx, England
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[4] Univ Manchester, Manchester, Lancs, England
[5] Cardiff Univ, Cardiff, Wales
[6] Azienda Unita Sanit Locale Reggio Emilia IRCCS, Med Phys Unit, Reggio Emilia, Italy
[7] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[8] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Radiat Phys & Protect, Oxford, England
[9] THEAGENIO Anticanc Hosp, Nucl Med Dept, Thessaloniki, Greece
[10] Lund Univ, Med Radiat Phys, Lund, Sweden
[11] Univ Oxford, Dept Oncol, Oxford, England
[12] Royal Surrey Cty Hosp, Guildford, Surrey, England
[13] Univ Surrey, Dept Phys, Guildford, Surrey, England
基金
欧盟地平线“2020”;
关键词
Quantitative SPECT; CT; Lu-177; SPECT; CT imaging; Standardization of SPECT; Harmonization of SPECT; International multicenter comparison exercise; Traceability of SPECT; Molecular radiotherapy (MRT); 3D printing; Phantom; VOLUME CORRECTION TECHNIQUES; DOSIMETRY; KIDNEY; PET; TOMOGRAPHY; PHANTOMS;
D O I
10.1186/s40658-021-00397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time-activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative Lu-177 SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
引用
收藏
页数:17
相关论文
共 47 条
  • [41] One Size Fits All? Assessment of the Use of a Simple Calibration Protocol for Quantitative SPECT/CT Imaging of 177Lu in European Hospitals
    Merrett, J.
    Fenwick, A.
    Scuffham, J.
    Johansson, L.
    Nisbet, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S184 - S184
  • [42] Quantitative 177Lu SPECT/CT imaging with a ring-shaped CZT-based camera: 208 vs 113 keV photopeak
    Danieli, R.
    Stella, M.
    Marin, C.
    Gia, J. Tran
    Leube, J.
    Uribe-Munoz, C.
    Hesse, M.
    Levillain, H.
    Vanderlinden, B.
    Reynaert, N.
    Flamen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S286 - S286
  • [43] A Pipeline for Automated Voxel Dosimetry: Application in Patients with Multi-SPECT/CT Imaging After 177Lu-Peptide Receptor Radionuclide Therapy
    Dewaraja, Yuni K.
    Mirando, David M.
    Peterson, Avery B.
    Niedbala, Jeremy
    Millet, John D.
    Mikell, Justin K.
    Frey, Kirk A.
    Wong, Ka Kit
    Wilderman, Scott J.
    Nelson, Aaron S.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (11) : 1665 - 1672
  • [44] Whole body planar and 3D quantitative imaging after 177Lu-DOTATATE on CZT SPECT/CT device with MEHRS collimator. First report
    Deshayes, Emmanuel
    Fersing, Cyril
    Hebert, Kevin
    Bardies, Manuel
    Kotzki, Pierre Olivier
    Santoro, Lore
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2021, 24 (02): : 165 - 166
  • [45] Biodistribution and dosimetry for combined [177Lu]Lu-PSMA-I&T/[225Ac]Ac-PSMA-I&T therapy using multi-isotope quantitative SPECT imaging
    Astrid Delker
    Mirjam Schleske
    Grigory Liubchenko
    Isabella Berg
    Mathias Johannes Zacherl
    Matthias Brendel
    Franz Josef Gildehaus
    Mikhail Rumiantcev
    Sandra Resch
    Kerstin Hürkamp
    Vera Wenter
    Lena M. Unterrainer
    Peter Bartenstein
    Sibylle I. Ziegler
    Leonie Beyer
    Guido Böning
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 1280 - 1290
  • [46] Biodistribution and dosimetry for combined [177Lu]Lu-PSMA-I&T/[225Ac]Ac-PSMA-I&T therapy using multi-isotope quantitative SPECT imaging
    Delker, Astrid
    Schleske, Mirjam
    Liubchenko, Grigory
    Berg, Isabella
    Zacherl, Mathias Johannes
    Brendel, Matthias
    Gildehaus, Franz Josef
    Rumiantcev, Mikhail
    Resch, Sandra
    Huerkamp, Kerstin
    Wenter, Vera
    Unterrainer, Lena M.
    Bartenstein, Peter
    Ziegler, Sibylle, I
    Beyer, Leonie
    Boening, Guido
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (05) : 1280 - 1290
  • [47] Preparation and SPECT/CT Imaging of 177Lu-Labeled Peptide Nucleic Acid (PNA) Targeting CITED1: Therapeutic Evaluation in Tumor-Bearing Nude Mice
    Li, Jia
    Zhang, Lei
    Li, Wenbo
    Lei, Chengming
    Cao, Yiyi
    Wang, Ying
    Wang, Zhengjie
    Pang, Hua
    ONCOTARGETS AND THERAPY, 2020, 13 : 487 - 496