A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project

被引:43
|
作者
Tran-Gia, Johannes [1 ]
Denis-Bacelar, Ana M. [2 ]
Ferreira, Kelley M. [2 ]
Robinson, Andrew P. [2 ,3 ,4 ]
Calvert, Nicholas [3 ]
Fenwick, Andrew J. [2 ,5 ]
Finocchiaro, Domenico [6 ,7 ]
Fioroni, Federica [6 ]
Grassi, Elisa [6 ]
Heetun, Warda [2 ]
Jewitt, Stephanie J. [8 ]
Kotzassarlidou, Maria [9 ]
Ljungberg, Michael [10 ]
McGowan, Daniel R. [8 ,11 ]
Scott, Nathaniel [8 ,13 ]
Scuffham, James [2 ,12 ]
Gleisner, Katarina Sjogreen [10 ]
Tipping, Jill [3 ]
Wevrett, Jill [2 ,12 ,13 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Natl Phys Lab, Teddington, Middx, England
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[4] Univ Manchester, Manchester, Lancs, England
[5] Cardiff Univ, Cardiff, Wales
[6] Azienda Unita Sanit Locale Reggio Emilia IRCCS, Med Phys Unit, Reggio Emilia, Italy
[7] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[8] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Radiat Phys & Protect, Oxford, England
[9] THEAGENIO Anticanc Hosp, Nucl Med Dept, Thessaloniki, Greece
[10] Lund Univ, Med Radiat Phys, Lund, Sweden
[11] Univ Oxford, Dept Oncol, Oxford, England
[12] Royal Surrey Cty Hosp, Guildford, Surrey, England
[13] Univ Surrey, Dept Phys, Guildford, Surrey, England
基金
欧盟地平线“2020”;
关键词
Quantitative SPECT; CT; Lu-177; SPECT; CT imaging; Standardization of SPECT; Harmonization of SPECT; International multicenter comparison exercise; Traceability of SPECT; Molecular radiotherapy (MRT); 3D printing; Phantom; VOLUME CORRECTION TECHNIQUES; DOSIMETRY; KIDNEY; PET; TOMOGRAPHY; PHANTOMS;
D O I
10.1186/s40658-021-00397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time-activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative Lu-177 SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
引用
收藏
页数:17
相关论文
共 47 条
  • [1] A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project
    Johannes Tran-Gia
    Ana M. Denis-Bacelar
    Kelley M. Ferreira
    Andrew P. Robinson
    Nicholas Calvert
    Andrew J. Fenwick
    Domenico Finocchiaro
    Federica Fioroni
    Elisa Grassi
    Warda Heetun
    Stephanie J. Jewitt
    Maria Kotzassarlidou
    Michael Ljungberg
    Daniel R. McGowan
    Nathaniel Scott
    James Scuffham
    Katarina Sjögreen Gleisner
    Jill Tipping
    Jill Wevrett
    Michael Lassmann
    EJNMMI Physics, 8
  • [2] An international quantitative SPECT/CT imaging exercise for Lu-177
    Tran-Gia, J.
    Robinson, A. P.
    Calvert, N.
    Denis-Bacelar, A. M.
    Fenwick, A. J.
    Ferreira, K. M.
    Finocchiaro, D.
    Fioroni, F.
    Grassi, E.
    Heetun, W.
    Jewitt, S. J.
    Kalathas, T.
    Kotzasarlidou, M.
    Ljungberg, M.
    McGowan, D. R.
    Scuffham, J.
    Gleisner, K. Sjogreen
    Tipping, J.
    Wevrett, J.
    Lassmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S15 - S16
  • [3] Performance evaluation and quantitative accuracy of a multi-pinhole small animal SPECT/CT scanner for theranostic Lu-177 imaging
    Gupta, Arun
    Kim, Kyeong Yun
    Lee, Min Sun
    Hwang, Donghwi
    Lee, Dong Soo
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [4] Quantitative SPECT imaging with Lu-177: A physical phantom evaluation
    He, Bin
    Nikolopoulou, Anastasia
    Osborne, Joseph
    Vallabhajosula, Shankar
    Goldsmith, Stanley
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Quantitative Imaging of Lu-177 on a Symbia T6 SPECT/CT
    Merrett, J. L.
    Fenwick, A. J.
    Yatigammana, D. N. B.
    Scuffham, J. W.
    Johansson, L. C.
    Nisbet, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S222 - S222
  • [6] Performance Evaluation and Quantitative Accuracy of Multipinhole NanoSPECT/CT Scanner for Theranostic Lu-177 Imaging
    Arun Gupta
    Kyeong Yun Kim
    Donghwi Hwang
    Min Sun Lee
    Dong Soo Lee
    Jae Sung Lee
    Journal of the Korean Physical Society, 2018, 72 : 1379 - 1386
  • [7] Performance Evaluation and Quantitative Accuracy of Multipinhole NanoSPECT/CT Scanner for Theranostic Lu-177 Imaging
    Gupta, Arun
    Kim, Kyeong Yun
    Hwang, Donghwi
    Lee, Min Sun
    Lee, Dong Soo
    Lee, Jae Sung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (11) : 1379 - 1386
  • [8] Quantitative Lu-177 SPECT/CT validation to assist theragnostic procedures
    Gnesin, S.
    Lima, T.
    Malterre, J.
    Verdun, F. R.
    Schaefer, N.
    Prior, J. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S178 - S178
  • [9] Gamma Camera Calibration for SPECT Based Quantitative Imaging with LU-177
    D'Arienzo, M.
    Cazzato, M.
    Ungania, S.
    Cozzella, L.
    Iaccarino, G.
    D'Andrea, M.
    Strigari, L.
    Fenwick, A.
    Johansson, L.
    Cox, M.
    De Felice, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S331 - S332
  • [10] Comparison of a 3D CZT and conventional SPECT/CT system for quantitative Lu-177 SPECT imaging
    Nuttens, Victor
    Schramm, Georg
    D'Asseler, Yves
    Koole, Michel
    EJNMMI PHYSICS, 2024, 11 (01)