Improvement of high-range-resolution imaging by considering change in ultrasonic waveform during propagation

被引:9
|
作者
Mozumi, Michiya [1 ]
Nagaoka, Ryo [2 ]
Hasegawa, Hideyuki [2 ]
机构
[1] Univ Toyama, Fac Engn, Toyama 9308555, Japan
[2] Univ Toyama, Grad Sch Sci & Engn Res, Toyama 9308555, Japan
关键词
MEDICAL ULTRASOUND; WALL;
D O I
10.7567/JJAP.57.07LF23
中图分类号
O59 [应用物理学];
学科分类号
摘要
The range spatial resolution is an important factor determining the quality of the ultrasound B-mode image. In this study, the transmit-receive response of a medical ultrasound system was estimated using ultrasound echoes from an imaging target and used instead of that estimated from an ultrasound echo from a fine wire in water as was done in our previous study. In addition, an estimation procedure of the transmit-receive response was performed region by region to consider the ultrasound attenuation during propagation. From the results using a wire phantom, the range full widths at half maximum (FWHMs) were 0.444 mm (conventional method) and 0.167 mm (our previous method), but it was further improved to 0.150 mm by the proposed method. (c) 2018 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 50 条
  • [41] High-Resolution Range Profile Synthesis Based on a New Radar Waveform
    Wang, Xinhai
    Zhang, Gong
    Li, Daren
    2016 CIE INTERNATIONAL CONFERENCE ON RADAR (RADAR), 2016,
  • [42] MIMO radar waveform design based on high-resolution range profile
    Liu Y.-F.
    Liu Z.
    Liu J.
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2011, 33 (04): : 755 - 758
  • [43] Super high resolution for long-range imaging
    Aruga, T
    Li, SW
    APPLIED OPTICS, 1999, 38 (13) : 2795 - 2799
  • [44] Novel high range resolution approach in microwave imaging
    Wang, Y
    Fang, DG
    IEE PROCEEDINGS-RADAR SONAR AND NAVIGATION, 1997, 144 (04) : 177 - 180
  • [45] IMPROVEMENT OF THE RESOLUTION IN ULTRASONIC-IMAGING WITH REAL-SYNTHETIC HYBRID APERTURE
    IKEGAMI, M
    YAMAMOTO, T
    AOKI, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1985, 24 : 193 - 195
  • [46] BISTATIC HIGH-RESOLUTION IMAGING ON A MONOSTATIC RANGE
    HERDEG, WF
    WENDEL, H
    ELECTRONICS LETTERS, 1990, 26 (18) : 1476 - 1477
  • [47] Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging
    Hideyuki Hasegawa
    Journal of Medical Ultrasonics, 2016, 43 : 19 - 27
  • [48] Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging
    Hasegawa, Hideyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2016, 43 (01) : 19 - 27
  • [49] High-range-resolution two-dimensional imaging using frequency diversity multiple-input-multiple-output sonar (vol 10, pg 983, 2016)
    Liu, Xionghou
    Sun, Chao
    Yang, Yixin
    Zhou, Jie
    IET RADAR SONAR AND NAVIGATION, 2016, 10 (04):
  • [50] Study of aperture area reduction and resolution improvement of underwater ultrasonic imaging system
    Cheng, SW
    Chao, MK
    PROCEEDINGS OF THE 1996 SYMPOSIUM ON AUTONOMOUS UNDERWATER VEHICLE TECHNOLOGY, 1996, : 325 - 332