Improvement of high-range-resolution imaging by considering change in ultrasonic waveform during propagation

被引:9
|
作者
Mozumi, Michiya [1 ]
Nagaoka, Ryo [2 ]
Hasegawa, Hideyuki [2 ]
机构
[1] Univ Toyama, Fac Engn, Toyama 9308555, Japan
[2] Univ Toyama, Grad Sch Sci & Engn Res, Toyama 9308555, Japan
关键词
MEDICAL ULTRASOUND; WALL;
D O I
10.7567/JJAP.57.07LF23
中图分类号
O59 [应用物理学];
学科分类号
摘要
The range spatial resolution is an important factor determining the quality of the ultrasound B-mode image. In this study, the transmit-receive response of a medical ultrasound system was estimated using ultrasound echoes from an imaging target and used instead of that estimated from an ultrasound echo from a fine wire in water as was done in our previous study. In addition, an estimation procedure of the transmit-receive response was performed region by region to consider the ultrasound attenuation during propagation. From the results using a wire phantom, the range full widths at half maximum (FWHMs) were 0.444 mm (conventional method) and 0.167 mm (our previous method), but it was further improved to 0.150 mm by the proposed method. (c) 2018 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 50 条
  • [21] High range resolution laser scanner with full waveform recording
    Letalick, Dietmar
    Larsson, Hakan
    Tolt, Gustav
    Allard, Lars
    Wollner, Erika
    Berglund, Folke
    ELECTRO-OPTICAL REMOTE SENSING, PHOTONIC TECHNOLOGIES, AND APPLICATIONS IV, 2010, 7835
  • [22] Improvement of Range Resolution of FDMAS Beamforming in Ultrasound Imaging
    Kozai, Ryoya
    Zhu, Jing
    Okubo, Kan
    Tagawa, Norio
    VISAPP: PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS, VOL 4, 2019, : 198 - 205
  • [23] High resolution 3D ultrasonic breast imaging by time-domain full waveform inversion
    Lucka, Felix
    Perez-Liva, Mailyn
    Treeby, Bradley E.
    Cox, Ben T.
    INVERSE PROBLEMS, 2022, 38 (02)
  • [24] High-resolution ultrasonic imaging of wood
    5737 Thornhill Drive, Oakland, CA 94611, United States
    不详
    不详
    Wood Sci Technol, 3 (185-198):
  • [25] High-resolution ultrasonic imaging of wood
    H. Berndt
    A. P. Schniewind
    G. C. Johnson
    Wood Science and Technology, 1999, 33 : 185 - 198
  • [26] HIGH RESOLUTION ULTRASONIC IMAGING SYSTEM.
    Hurwitz, M.J.
    1600, Gordon & Breach, New York, NY (05):
  • [27] High-resolution ultrasonic environment imaging
    Bank, Dirk
    Kaempke, Thomas
    IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (02) : 370 - 381
  • [28] High-resolution ultrasonic imaging of wood
    Berndt, H
    Schniewind, AP
    Johnson, GC
    WOOD SCIENCE AND TECHNOLOGY, 1999, 33 (03) : 185 - 198
  • [29] HIGH-RESOLUTION ULTRASONIC-IMAGING
    BERSON, M
    FEUILLARD, G
    DIRIDOLLOU, S
    LETIECQ, M
    POURCELOT, L
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C5): : 1285 - 1288
  • [30] High-range-resolution velocity-estimation techniques for coherent Doppler lidars with exponentially shaped laser pulses
    Gurdev, Ljuan L.
    Dreischuh, Tanja N.
    Stoyanov, Dimitar V.
    Applied Optics, 2002, 41 (09): : 1741 - 1749