A NOVEL NONINVASIVE IMPEDANCE-BASED TECHNIQUE FOR CENTRAL VENOUS PRESSURE MEASUREMENT

被引:6
|
作者
Ward, Kevin R. [1 ,2 ,3 ]
Tiba, Mohamad H. [1 ,2 ]
Draucker, Gerard T. [1 ,2 ]
Proffitt, Elizabeth K. [1 ,2 ,4 ]
Barbee, Robert W. [1 ,2 ,3 ]
Gunnerson, Kyle J. [1 ,2 ,5 ]
Reynolds, Penny S. [1 ,2 ]
Spiess, Bruce D. [1 ,2 ,5 ]
机构
[1] Virginia Commonwealth Univ Reanimat Engn Shock Ct, Richmond, VA USA
[2] Virginia Commonwealth Univ, Dept Emergency Med, Richmond, VA USA
[3] Virginia Commonwealth Univ, Dept Physiol, Richmond, VA USA
[4] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA USA
[5] Virginia Commonwealth Univ, Dept Anesthesiol, Richmond, VA USA
来源
SHOCK | 2010年 / 33卷 / 03期
关键词
Monitoring; catheter; critical illness; injury; volume assessment; CRITICALLY-ILL PATIENTS; ADVANCED HEART-FAILURE; HEMODYNAMIC ASSESSMENT; SEVERE SEPSIS; SEPTIC SHOCK; AGREEMENT; CATHETERIZATION; ULTRASOUND;
D O I
10.1097/SHK.0b013e3181ab9b9b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Knowledge of central venous pressure (CVP) is considered valuable in the assessment and treatment of various states of critical illness and injury. We tested a noninvasive means of determining CVP (NICVP) by monitoring upper arm blood flow changes in response to externally applied circumferential pressure to the upper arm veins. Thirty-six patients who were undergoing CVP monitoring as part of their care had NICVP determined and compared with CVP. Volume changes were measured in the upper arm using tetra-polar impedance plethysmography underneath a blood pressure cuff. The cuff was inflated over 5 s to a pressure greater than CVP but less than diastolic arterial pressure. After 45 to 60 s, the cuff was rapidly deflated. Noninvasive CVP was determined as the cuff pressure noted at the maximum derivative of the volume increase under the cuff during deflation. Noninvasive CVP was then compared with invasively measured CVP taken during the same period by Bland-Altman analysis. A total of 108 trials (three per subject) were performed on 36 patients. Mean bias was -0.26 mmHg (95% confidence interval [CI]: -0.67, 0.15). Limits of agreement were -2.7 and 2.2 mmHg with the 95% CI for the lower limit of agreement (-3.4, -2.0 mmHg) and for the upper limit of agreement (1.5, 2.9 mmHg). Correlation between CVP and NICVP was 0.95 (95% CI: 0.93 to 0.97; P < 0.0001). Noninvasive CVP as determined in this study may be a clinically useful substitute for traditional CVP measurement and may offer a tool for early diagnosis and treatment of acute states in which knowledge of CVP would be helpful.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [1] Noninvasive Measurement of Central Venous Pressure
    Ward, Kevin
    Tiba, Mohamad
    Draucker, Gerald
    Gunnerson, Kyle
    Barbee, Robert
    Reynolds, Penny
    Spiess, Bruce
    Ivatury, Rao
    CIRCULATION, 2009, 120 (18) : S1460 - S1460
  • [2] IVC measurement for the noninvasive evaluation of central venous pressure
    Ruge, Max
    Marhefka, Gregary D.
    JOURNAL OF ECHOCARDIOGRAPHY, 2022, 20 (03) : 133 - 143
  • [3] IVC measurement for the noninvasive evaluation of central venous pressure
    Max Ruge
    Gregary D. Marhefka
    Journal of Echocardiography, 2022, 20 : 133 - 143
  • [4] IMPEDANCE MEASUREMENT AS A NONINVASIVE TECHNIQUE FOR THE MONITORING OF INTRACRANIAL-PRESSURE VARIATIONS
    MAGNANO, M
    ALBERA, R
    LACILLA, M
    GABINI, A
    NADDEO, M
    BRUNO, D
    AUDIOLOGY, 1994, 33 (04): : 237 - 243
  • [5] A technique for central venous pressure measurement in normal horses
    Wilsterman, Sonya
    Hackett, Eileen S.
    Rao, Sangeeta
    Hackett, Timothy B.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2009, 19 (03) : 241 - 246
  • [6] Noninvasive central venous pressure measurement by controlled compression Sonography at the forearm
    Thalhammer, Christoph
    Aschwanden, Markus
    Odermatt, Angela
    Baumann, Ulrich A.
    Imfeld, Stephan
    Bilecen, Deniz
    Marsch, Stephan C.
    Jaeger, Kurt A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (16) : 1584 - 1589
  • [7] NONINVASIVE MEASUREMENT OF CENTRAL VENOUS-PRESSURE BY NECK INDUCTIVE PLETHYSMOGRAPHY
    BLOCH, KE
    KRIEGER, BP
    SACKNER, MA
    CHEST, 1991, 100 (02) : 371 - 375
  • [8] Noninvasive central venous pressure monitoring
    Ward, K
    Tiba, MH
    Proffitt, K
    Draucker, J
    Ivatury, R
    Barbee, RW
    Spiess, B
    Arrowood, J
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A54 - A54
  • [9] Noninvasive measurement of systolic blood pressure in rats: A novel technique
    Gangwar, Anil
    Kumar, Pradeep
    Rawat, Anita
    Tiwari, Sunita
    INDIAN JOURNAL OF PHARMACOLOGY, 2014, 46 (03) : 351 - 352
  • [10] Ultrasound-guided noninvasive measurement of a patient's central venous pressure
    Aggarwal, Vikram
    Chatterjee, Aniruddha
    Cho, Yoonju
    Cheung, Dickson
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3696 - +