Development of the R2SUNED Code System for Shutdown Dose Rate Calculations

被引:46
|
作者
Sauvan, P. [1 ]
Catalan, J. P. [1 ]
Ogando, F. [1 ]
Juarez, R. [1 ]
Sanz, J. [1 ]
机构
[1] UNED, Dept Ingn Energet, Madrid 28040, Spain
关键词
Coupled radiation transport-activation calculations; DEMO; fusion neutronics; ITER; MCNP; R2S methodology; shutdown dose rate;
D O I
10.1109/TNS.2015.2507138
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
R2SUNED is a code system implementing the meshbased Rigorous-two-step method for shutdown dose rates calculations, making use of MCNP and ACAB codes. In addition to the most relevant features of state-of-the-art R2S systems, novel and unique features have been implemented in R2SUNED to overcome limitations common to the current mesh-based R2S implementations. One of particular interest is the cell-under-voxel approach intended to address most of the issues associated with the conventional averaging technique used in the neutron flux determination. The underlying idea is to identify the cells enclosed in each voxel and calculate the average value of the neutron flux within each cell fraction. Subsequently, the activation of each material, filling the cell delimited by the voxel, is calculated using the neutron flux evaluated in the corresponding cell. This capability enables to properly resolve the strong spatial gradients of the neutron flux independently of geometrical considerations. Another relevant feature is that a flexible decay gamma source sampling has been incorporated to assure an efficient decay gamma transport in a vast diversity of problems. A verification of R2SUNED has been addressed on the ITER computational shutdown dose rate benchmark. It is highlighted both the limitations of voxel averaged neutron flux standard approach, and the ability of R2SUNED to overcome this issue. The excellent agreement of the results with those obtained using a mesh matching perfectly the geometry tells that R2SUNED performs correctly. Finally, a description of the most representative applications carried out with R2SUNED is provided for fusion relevant facilities.
引用
收藏
页码:375 / 384
页数:10
相关论文
共 50 条
  • [41] Impact of Radiation Dose Rate on Mammary Gland Development and Immune System
    Pluth, J. M.
    To, J.
    Knoblauch, T.
    Wiedmeyer, B.
    Sridharan, D. M.
    Mori, H.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2019, 60 : 35 - 35
  • [42] Development of an Ultrahigh Dose-Rate Small Animal Radiotherapy System
    Zheng, C.
    Yuan, X.
    Liu, H.
    Yang, Y.
    MEDICAL PHYSICS, 2024, 51 (09) : 6566 - 6566
  • [43] JS']JSIR2S Code System For Delayed Radiation Field Calculations
    Ambrozic, Klemen
    Kos, Bor
    Snoj, Luka
    27TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2018), 2018,
  • [44] Further development of the LNMRI/IRD's TNF2 thermal system for flexible dose rate irradiation
    Astuto, Achilles
    Patrao, Karla C. S.
    Fonseca, Evaldo S.
    Pereira, Walsan W.
    Lopes, Ricardo T.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1716 - 1719
  • [45] Validation of Particle and Heavy Ion Transport Code System (PHITS) in generating dose-voxel kernels for internal dosimetry calculations
    Tatu, Shalaine Sana
    Kelley, Brian M.
    Wong, Yin How
    Kasbollah, Azahari
    Suppiah, Subapriya
    Phuna, Zhi Xin
    Kappadath, S. Cheenu
    Yeong, Chai Hong
    HEALTH AND TECHNOLOGY, 2025,
  • [46] Alpha dose rate calculations for UO2 based materials using stopping power models
    Hansson, N. L.
    Ekberg, C.
    Spahiu, K.
    NUCLEAR MATERIALS AND ENERGY, 2020, 22
  • [47] PANTHERE V2: MULTIPURPOSE SIMULATION SOFTWARE FOR 3D DOSE RATE CALCULATIONS
    Penessot, Gael
    Bavoil, Eleonore
    Wertz, Laurent
    Malouch, Fadhel
    Visonneau, Thierry
    Dubost, Julien
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [48] Beam Dump of SPIRAL2 Facility: Residual Dose Rate Calculations and Impact of the Computational Approaches
    Mayoral, A.
    Sanz, J.
    Lopez, D.
    Schibler, E.
    Perrot, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1665 - 1671
  • [49] Development of the Scintillator Imaging System for the Measurement of the Dose Volume with High-Sampling Rate
    Tsuneda, M.
    Nishio, T.
    Ezura, T.
    Karasawa, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E747 - E747
  • [50] Development of a Remote and Multipoint Air-dose Rate Monitoring System Using Webcams
    Kin, T.
    Watanabe, Y.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,