Development of the R2SUNED Code System for Shutdown Dose Rate Calculations

被引:46
|
作者
Sauvan, P. [1 ]
Catalan, J. P. [1 ]
Ogando, F. [1 ]
Juarez, R. [1 ]
Sanz, J. [1 ]
机构
[1] UNED, Dept Ingn Energet, Madrid 28040, Spain
关键词
Coupled radiation transport-activation calculations; DEMO; fusion neutronics; ITER; MCNP; R2S methodology; shutdown dose rate;
D O I
10.1109/TNS.2015.2507138
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
R2SUNED is a code system implementing the meshbased Rigorous-two-step method for shutdown dose rates calculations, making use of MCNP and ACAB codes. In addition to the most relevant features of state-of-the-art R2S systems, novel and unique features have been implemented in R2SUNED to overcome limitations common to the current mesh-based R2S implementations. One of particular interest is the cell-under-voxel approach intended to address most of the issues associated with the conventional averaging technique used in the neutron flux determination. The underlying idea is to identify the cells enclosed in each voxel and calculate the average value of the neutron flux within each cell fraction. Subsequently, the activation of each material, filling the cell delimited by the voxel, is calculated using the neutron flux evaluated in the corresponding cell. This capability enables to properly resolve the strong spatial gradients of the neutron flux independently of geometrical considerations. Another relevant feature is that a flexible decay gamma source sampling has been incorporated to assure an efficient decay gamma transport in a vast diversity of problems. A verification of R2SUNED has been addressed on the ITER computational shutdown dose rate benchmark. It is highlighted both the limitations of voxel averaged neutron flux standard approach, and the ability of R2SUNED to overcome this issue. The excellent agreement of the results with those obtained using a mesh matching perfectly the geometry tells that R2SUNED performs correctly. Finally, a description of the most representative applications carried out with R2SUNED is provided for fusion relevant facilities.
引用
收藏
页码:375 / 384
页数:10
相关论文
共 50 条
  • [21] Shutdown dose rate experiment at JET during DTE2
    Fonnesu, N.
    Loreti, S.
    Villari, R.
    Flammini, D.
    Mariano, G.
    Batistoni, P.
    Colangeli, A.
    Moro, F.
    Previti, A.
    Klix, A.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (05):
  • [22] Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow
    Bae, Jin Whan
    Kos, Bor
    Biondo, Elliott
    FUSION ENGINEERING AND DESIGN, 2023, 194
  • [23] Shutdown dose rate studies for the DTE2 campaign at JET
    Fonnesu, N.
    Villari, R.
    Flammini, D.
    Batistoni, P.
    Fischer, U.
    Pereslavtsev, P.
    FUSION ENGINEERING AND DESIGN, 2020, 161
  • [24] Monte Carlo based operational and shutdown dose rate calculations of HT-7U tokamak
    Chen, YX
    Wu, YC
    Huang, QY
    FUSION ENGINEERING AND DESIGN, 2004, 70 (02) : 155 - 162
  • [25] Development of unstructured mesh tally capability in cosRMC and application to shutdown dose rate analysis
    Zhang, Xian
    Liu, Shichang
    Wang, Zhenyu
    Chen, Yixue
    FUSION ENGINEERING AND DESIGN, 2022, 181
  • [26] Shutdown dose rate assessment for a DCLL blanket-based reactor: Application of the R2S-UNED approach
    Pablo Catalan, Juan
    Sauvan, Patrick
    Sanz, Javier
    FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 2088 - 2091
  • [27] Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER
    Mota, F.
    Peneliau, Y.
    Catalan, J. P.
    Alguacil, J.
    Medrano, M.
    Rincon, E.
    Cabrera, S.
    Carrasco, R.
    Lapayese, F.
    Pastor, C.
    de la Pena, A.
    Pereira, A.
    Queral, V.
    Ramos, F.
    Rodriguez, C.
    Soleto, A.
    Letellier, L.
    Le Guern, F.
    Piqueras, J. J.
    FUSION ENGINEERING AND DESIGN, 2021, 172
  • [28] Effects of organic impurities on BWR water chemistry, (2) effects on shutdown dose rate
    Igarashi, H
    Ohsumi, K
    Uchida, S
    Matsui, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1999, 36 (09) : 805 - 817
  • [29] Development and evaluation of additional shutdown system at the Ignalina NPP by employing RELAP5 code
    Kaliatka, A
    Uspuras, E
    NUCLEAR ENGINEERING AND DESIGN, 2002, 217 (1-2) : 129 - 139
  • [30] Development of fast Monte Carlo code for high dose rate brachytherapy
    Hu, Ankang
    Qiu, Rui
    Wu, Zhen
    Li, Chunyan
    Zhang, Hui
    Li, Junli
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305